Development, validation and application of a method to analyze phenols in water samples by solid phase micro extraction-gas chromatography-flame ionization detector

被引:10
|
作者
Lancas, Fernando M. [1 ]
Olivares, Igor R. B. [1 ]
Alves, Priscila M. [1 ]
机构
[1] Univ Sao Paulo, Inst Chem, BR-13560970 Sao Carlos, SP, Brazil
关键词
phenol; SPME; chromatographyp; FID; water; mass spectrometer; GC/MS; brazil; river; atibaia;
D O I
10.1080/03601230701391468
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this work the development, validation and application of method using Solid Phase Microexctration (SPME) for the analyses of five pollutants (phenol, 2-nitrophenol, 2,4-dimethylphenol, 2,4-dichlorophenol and 4-chloro, 3-methyl phenol) in supplying water, using gas chromatography (GC) with flame ionization detector (FID) is described. The optimal conditions obtained for SPME were: fiber type: Poliacrylate (PA); extraction time: 40 minutes; extraction temperature: 70 degrees C; amount of salt added to sample (NaCl): 15%; desorption temperature: 8 minutes. The parameters studied in the method validation were: limit of detection (0.3 and 3.5 mu g.L-1); precision, measured by the variation coefficient (between 2.1 and 8.8%); calibration curve and linearity, by using the external standardization method (between 1 and 50 50 mu g.L-1). After the methodology development, samples of water collected in Atibaia River (Sao Paulo - Brazil) were analyzed, using the optimized methodology. Three water samples collected in the rain season showed a peak with retention time close to 4-chloro, 3 methyl phenol further analyzed by Gas Chromatography-Mass Spectrometry for the identity confirmation. In spite of the fact that none target compounds were found in the river water samples analyzed, the presence of two phenols different from those investigated (p-terc butyl phenol; butylated hydroxytoluene) were detected. These results together with the results of the limit of detection (that showed to be lower than the maximum concentration of phenols demanded by different environment control agencies), and the results of the validation, indicate the applicability of this method for the analysis of selected phenols in river water samples.
引用
收藏
页码:491 / 498
页数:8
相关论文
共 50 条
  • [41] DETERMINATION OF METHYL ETHYL KETONE IN URINE SAMPLES BY HEADSPACE SOLID PHASE MICRO EXTRACTION (SPME) SAMPLING ASSOCIATED TO GAS CHROMATOGRAPHY WITH FLAME-IONIZATION DETECTOR (GC-FID)
    Antunes, Marina Venzon
    Linden, Rafael
    QUIMICA NOVA, 2008, 31 (08): : 2165 - 2168
  • [42] Determination of phthalate esters in drinking water and edible vegetable oil samples by headspace solid phase microextraction using graphene/polyvinylchloride nanocomposite coated fiber coupled to gas chromatography-flame ionization detector
    Amanzadeh, Hatam
    Yamini, Yadollah
    Moradi, Morteza
    Asl, Yousef Abdossalmi
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1465 : 38 - 46
  • [43] Application of Headspace Gas Chromatography with Flame Ionization Detector for Determination of Carboxyhemoglobin in Forensic Blood Samples
    Le, Dinh-Vu
    Dang, Minh-Thu
    JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 76 (12) : 1430 - 1434
  • [44] Application of Headspace Gas Chromatography with Flame Ionization Detector for Determination of Carboxyhemoglobin in Forensic Blood Samples
    Dinh-Vu Le
    Minh-Thu Dang
    Journal of Analytical Chemistry, 2021, 76 : 1430 - 1434
  • [45] Development of a Gas Chromatography-Flame Ionization Method for the Detection and Quantification of 12 Flavoring Agents in Supplementary Feed
    Lee, Mi Jin
    Lee, Jeong Min
    Kim, Sungjin
    Park, Hye Jin
    Jeon, Cheon Seok
    Hong, Hyun Jin
    Choi, Sung Min
    Cho, Soon Kil
    Ahn, Jong Sung
    Kim, Ho Jin
    JOURNAL OF AOAC INTERNATIONAL, 2020, 103 (03) : 710 - 714
  • [46] Determination of fuel dialkyl ethers and BTEX in water using headspace solid-phase microextraction and gas chromatography-flame ionization detection
    Arambarri, I
    Lasa, M
    Garcia, R
    Millán, E
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1033 (02) : 193 - 203
  • [47] Determination of ethanol in ionic liquids using headspace solid-phase micro extraction-gas chromatography
    Zhao, Fei
    Ponnaiyan, Thehazhnan K.
    Graham, Christa M.
    Schall, Constance A.
    Varanasi, Sasidhar
    Anderson, Jared L.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 392 (7-8) : 1271 - 1275
  • [48] Determination of fluoride in toothpaste using headspace solid-phase microextraction and gas chromatography-flame ionization detection
    Wejnerowska, Grazyna
    Karczmarek, Anna
    Gaca, Jerzy
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1150 (1-2) : 173 - 177
  • [49] Off-line Solid Phase Extraction Combined with Gas Chromatography-Flame Ionization Detection Method for Determination of Mineral oil Saturated and Aromatic Hydrocarbons in Olive Oils
    Ke Run-Hui
    Yang Chun-Yan
    Hu Xue
    Xie Rui-Long
    Yin Jian-Jun
    Song Quan-Hou
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 46 (10) : 1677 - 1684
  • [50] Development and validation of a new gas flame ionization detector method for the determination of finasteride in tablets
    Saglik, Serap
    Ulu, Sevgi Tatar
    ANALYTICAL BIOCHEMISTRY, 2006, 352 (02) : 260 - 264