Development, validation and application of a method to analyze phenols in water samples by solid phase micro extraction-gas chromatography-flame ionization detector

被引:10
|
作者
Lancas, Fernando M. [1 ]
Olivares, Igor R. B. [1 ]
Alves, Priscila M. [1 ]
机构
[1] Univ Sao Paulo, Inst Chem, BR-13560970 Sao Carlos, SP, Brazil
关键词
phenol; SPME; chromatographyp; FID; water; mass spectrometer; GC/MS; brazil; river; atibaia;
D O I
10.1080/03601230701391468
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this work the development, validation and application of method using Solid Phase Microexctration (SPME) for the analyses of five pollutants (phenol, 2-nitrophenol, 2,4-dimethylphenol, 2,4-dichlorophenol and 4-chloro, 3-methyl phenol) in supplying water, using gas chromatography (GC) with flame ionization detector (FID) is described. The optimal conditions obtained for SPME were: fiber type: Poliacrylate (PA); extraction time: 40 minutes; extraction temperature: 70 degrees C; amount of salt added to sample (NaCl): 15%; desorption temperature: 8 minutes. The parameters studied in the method validation were: limit of detection (0.3 and 3.5 mu g.L-1); precision, measured by the variation coefficient (between 2.1 and 8.8%); calibration curve and linearity, by using the external standardization method (between 1 and 50 50 mu g.L-1). After the methodology development, samples of water collected in Atibaia River (Sao Paulo - Brazil) were analyzed, using the optimized methodology. Three water samples collected in the rain season showed a peak with retention time close to 4-chloro, 3 methyl phenol further analyzed by Gas Chromatography-Mass Spectrometry for the identity confirmation. In spite of the fact that none target compounds were found in the river water samples analyzed, the presence of two phenols different from those investigated (p-terc butyl phenol; butylated hydroxytoluene) were detected. These results together with the results of the limit of detection (that showed to be lower than the maximum concentration of phenols demanded by different environment control agencies), and the results of the validation, indicate the applicability of this method for the analysis of selected phenols in river water samples.
引用
收藏
页码:491 / 498
页数:8
相关论文
共 50 条
  • [21] Magnetic solid phase extraction combined with gas chromatography-flame photometric detection for the determination of organophosphorus pesticides in juice samples
    Huang Qian
    He Man
    Chen Beibei
    Hu Bin
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2014, 32 (10) : 1131 - 1137
  • [22] Comparative study of the three sol-gel based solid phase microextraction fibers in extraction of BTEX from water samples using gas chromatography-flame ionization detection
    Sarafraz-Yazdi, Ali
    Moghadam, Hamed Piri
    Es'haghi, Zarrin
    Sepehr, Soroosh
    ANALYTICAL METHODS, 2010, 2 (06) : 746 - 752
  • [23] VALIDATION OF A GAS CHROMATOGRAPHY-FLAME IONIZATION METHOD FOR QUALITY CONTROL AND SPOILAGE DETECTION IN WINE AND CIDER
    Mangas, J. J.
    Rodriguez, R.
    Suarez, B.
    ACTA ALIMENTARIA, 2018, 47 (01) : 17 - 25
  • [24] Determination of butyltin species in water and sediment by solid-phase microextraction-gas chromatography-flame ionization detection
    Millán, E
    Pawliszyn, J
    JOURNAL OF CHROMATOGRAPHY A, 2000, 873 (01) : 63 - 71
  • [25] BTEX determination in water matrices using HF-LPME with gas chromatography-flame ionization detector
    Sarafraz-Yazdi, A.
    Amiri, A. H.
    Es'haghi, Z.
    CHEMOSPHERE, 2008, 71 (04) : 671 - 676
  • [26] Headspace gas chromatography-flame ionization detector method for organic solvent residue analysis in dietary supplements
    Jeong, Mijeong Lee
    Zahn, Michael
    Trinh, Thao
    Jia, Qi
    Ma, Wenwen
    JOURNAL OF AOAC INTERNATIONAL, 2006, 89 (06) : 1475 - 1482
  • [27] Application of on-line solid-phase extraction-gas chromatography-mass spectrometry to the determination of endocrine disruptors in water samples
    Brossa, L
    Marcé, RM
    Borrull, F
    Pocurull, E
    JOURNAL OF CHROMATOGRAPHY A, 2002, 963 (1-2) : 287 - 294
  • [28] Development and validation of headspace gas chromatography with a flame ionization detector method for the determination of ethanol in the vitreous humor
    Mihajlovic, Filip
    Andric, Ivana
    Slovic, Zivana
    Vujovic, Maja
    Piskulic, Kristina
    Dordevic, Snezana
    OPEN MEDICINE, 2025, 20 (01):
  • [29] Development and Validation of a Method for Alcohol Analysis in Brain Tissue by Headspace Gas Chromatography with Flame Ionization Detector
    Chun, Hao-Jung
    Poklis, Justin L.
    Poklis, Alphonse
    Wolf, Carl E.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2016, 40 (08) : 653 - 658
  • [30] Determination of organophosphorus pesticides in water samples by single drop microextraction and gas chromatography-flame photometric detector
    Ahmadi, F
    Assadi, Y
    Hosseini, SMRM
    Rezaee, M
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1101 (1-2) : 307 - 312