Development, validation and application of a method to analyze phenols in water samples by solid phase micro extraction-gas chromatography-flame ionization detector

被引:10
|
作者
Lancas, Fernando M. [1 ]
Olivares, Igor R. B. [1 ]
Alves, Priscila M. [1 ]
机构
[1] Univ Sao Paulo, Inst Chem, BR-13560970 Sao Carlos, SP, Brazil
关键词
phenol; SPME; chromatographyp; FID; water; mass spectrometer; GC/MS; brazil; river; atibaia;
D O I
10.1080/03601230701391468
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this work the development, validation and application of method using Solid Phase Microexctration (SPME) for the analyses of five pollutants (phenol, 2-nitrophenol, 2,4-dimethylphenol, 2,4-dichlorophenol and 4-chloro, 3-methyl phenol) in supplying water, using gas chromatography (GC) with flame ionization detector (FID) is described. The optimal conditions obtained for SPME were: fiber type: Poliacrylate (PA); extraction time: 40 minutes; extraction temperature: 70 degrees C; amount of salt added to sample (NaCl): 15%; desorption temperature: 8 minutes. The parameters studied in the method validation were: limit of detection (0.3 and 3.5 mu g.L-1); precision, measured by the variation coefficient (between 2.1 and 8.8%); calibration curve and linearity, by using the external standardization method (between 1 and 50 50 mu g.L-1). After the methodology development, samples of water collected in Atibaia River (Sao Paulo - Brazil) were analyzed, using the optimized methodology. Three water samples collected in the rain season showed a peak with retention time close to 4-chloro, 3 methyl phenol further analyzed by Gas Chromatography-Mass Spectrometry for the identity confirmation. In spite of the fact that none target compounds were found in the river water samples analyzed, the presence of two phenols different from those investigated (p-terc butyl phenol; butylated hydroxytoluene) were detected. These results together with the results of the limit of detection (that showed to be lower than the maximum concentration of phenols demanded by different environment control agencies), and the results of the validation, indicate the applicability of this method for the analysis of selected phenols in river water samples.
引用
收藏
页码:491 / 498
页数:8
相关论文
共 50 条
  • [1] Exploring petroleum hydrocarbons in groundwater by double solid phase extraction coupled to gas chromatography-flame ionization detector
    Pindado Jimenez, Oscar
    Perez Pastor, Rosa Ma
    Escolano Segovia, Olga
    del Reino Querencia, Susana
    TALANTA, 2015, 131 : 315 - 324
  • [2] Analytical method for monitoring airborne trimethylamine using solid phase micro-extraction and gas chromatography-flame ionization detection
    Chien, YC
    Uang, SN
    Kuo, CT
    Shih, TS
    Jen, JF
    ANALYTICA CHIMICA ACTA, 2000, 419 (01) : 73 - 79
  • [3] Stability-Indicating Method Development and Validation for Busulfan Drug Substance by Gas Chromatography-Flame Ionization Detector
    Khan, Ashraf
    Winter, Greg
    Tan, Shane
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2021, 59 (02) : 112 - 119
  • [4] Development of a poly(ethylene glycol)-graphene oxide sol-gel coating for solid-phase microextraction of aromatic amines in water samples with a gas chromatography-flame ionization detector method
    Sarafraz-Yazdi, Ali
    Yekkebashi, Ali
    NEW JOURNAL OF CHEMISTRY, 2015, 39 (02) : 1287 - 1294
  • [5] Development and validation of a gas chromatography-flame ionization detection method for quantifying sucrose in equine serum
    Hewetson, Michael
    Aaltonen, Kaisa
    Tulamo, Riitta-Mari
    Sankari, Satu
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2014, 26 (02) : 232 - 239
  • [6] A quantitative headspace-solid-phase microextraction-gas chromatography-flame ionization detector method to analyze short chain free fatty acids in rat feces
    Fiorini, Dennis
    Boarelli, Maria Chiara
    Gabbianelli, Rosita
    Ballini, Roberto
    Pacetti, Deborah
    ANALYTICAL BIOCHEMISTRY, 2016, 508 : 12 - 14
  • [7] In-situ formation of CO2-incorportaed solid sorbent for dispersive solid phase extraction of phenolic compounds from water and wastewater samples prior to gas chromatography-flame ionization detector
    Mardani, Asghar
    Farajzadeh, Mir Ali
    Nemati, Mahboob
    Mogaddam, Mohammad Reza Afshar
    ANALYTICA CHIMICA ACTA, 2024, 1287
  • [8] Determination of organophosphorus pesticide residues in vegetables using solid phase micro-extraction coupled with gas chromatography-flame photometric detector
    Sapahin, Haizarul Aida
    Makahleh, Ahmad
    Saad, Bahruddin
    ARABIAN JOURNAL OF CHEMISTRY, 2019, 12 (08) : 1934 - 1944
  • [9] Online Solid-Phase Extraction-Gas Chromatography-Flame Ionization Detection System for Monitoring Contaminants at Parts-Per-Trillion Concentrations in Process Waters
    Lejaegere, Charlotte
    Vercammen, Joeri
    Verheyden, Loes
    Martens, Johan A.
    LCGC EUROPE, 2023, 36 (01) : 7 - 13
  • [10] High performance mini-gas chromatography-flame ionization detector system based on micro gas chromatography column
    Zhu, Xiaofeng
    Sun, Jianhai
    Ning, Zhanwu
    Zhang, Yanni
    Liu, Jinhua
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (04):