Data processing approach for localizing bio-magnetic sources in the brain

被引:0
|
作者
Pai, Hung-, I [1 ]
Tseng, Chih-Yuan [1 ]
Lee, H. C. [1 ,2 ]
机构
[1] Natl Cent Univ, Dept Phys, Computat Biol Lab, Jhongli 320, Taiwan
[2] Natl Cent Univ, Grad Inst Syst Biol & Bioinformat, Jhongli 320, Taiwan
来源
NOISE AND FLUCTUATIONS | 2007年 / 922卷
关键词
MEG; ill-posed inverse problem; cluster; maximum entropy;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Magnetoencephalography (MEG) provides dynamic spatial-temporal insight for neural activities in the cortex. Because the possible number of sources is far greater than the number of MEG detectors, the proposition to localize sources directly from MEG data is ill-posed. Here we develop a novel approach based on a sequence of data processing procedures that includes a clustering process, an intersection analysis, and an application of the maximum entropy method. We examine the performance of our method and compare it with the minimum-norm least-square inverse method using an artificial noisy MEG data.
引用
收藏
页码:701 / +
页数:3
相关论文
共 50 条
  • [31] A Novel Bio-Controller for Localizing Pollution Sources in a Medium Peclet Environment
    Oyekan, John
    Hu, Huosheng
    JOURNAL OF BIONIC ENGINEERING, 2010, 7 (04) : 345 - 353
  • [32] Localizing Sources of Brain Disease Progression with Network Diffusion Model
    Hu, Chenhui
    Hua, Xue
    Ying, Jun
    Thompson, Paul M.
    Fakhri, Georges E.
    Li, Quanzheng
    IEEE JOURNAL OF SELECTED TOPICS IN SIGNAL PROCESSING, 2016, 10 (07) : 1214 - 1225
  • [33] A bio-magnetic bead separator on glass chips using semi-encapsulated spiral electromagnets
    Liakopoulos, TM
    Choi, JW
    Ahn, CH
    TRANSDUCERS 97 - 1997 INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS AND ACTUATORS, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 1997, : 485 - 488
  • [34] Wastewater treatment by bio-magnetic separation: A comparison of iron oxide and iron sulphide biomass recovery
    Bahaj, AS
    James, PAB
    Moeschler, FD
    WATER SCIENCE AND TECHNOLOGY, 1998, 38 (06) : 311 - 317
  • [35] Use of a novel bio-magnetic nanocomposite synthesized from industrial tomato processing waste for methylene blue removal: sorption optimization, kinetic and isotherm studies
    Teymur, Yekbun Avsar
    Guzel, Fuat
    Koyuncu, Filiz
    Saygili, Gulbahar Akkaya
    CELLULOSE, 2020, 27 (16) : 9577 - 9591
  • [36] Crosstalk analysis and suppression of optically pumped magnetometer array for bio-magnetic field measurement systems
    Yuan, Ziqi
    Liu, Ying
    Lin, Shudong
    Cao, Li
    Tang, Junjian
    Lei, Gaoyi
    Zhai, Yueyang
    MEASUREMENT, 2024, 237
  • [37] BIO-MAGNETIC FLOW OF HEAT TRANSFER OVER MOVING HORIZONTAL PLATE BY THE PRESENCE OF VARIABLE VISCOSITY AND TEMPERATURE
    Jumana, Sadia Anjum
    Ferdows, M.
    Tzirtzilakis, E. E.
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2022, 22 (10)
  • [38] Localizing the site of magnetic brain stimulation by functional MRI
    Terao, Y
    Ugawa, Y
    Sakai, K
    Miyauchi, S
    Fukuda, H
    Sasaki, Y
    Takino, T
    Hanajima, R
    Furubayashi, T
    Pütz, B
    Kanazawa, I
    EXPERIMENTAL BRAIN RESEARCH, 1998, 121 (02) : 145 - 152
  • [39] Localizing the site of magnetic brain stimulation by functional MRI
    Y. Terao
    Yoshikazu Ugawa
    Katsuyuki Sakai
    Satoru Miyauchi
    Hideki Fukuda
    Yuka Sasaki
    Ryouichi Takino
    Ritsuko Hanajima
    Toshiaki Furubayashi
    Benno Pütz
    Ichiro Kanazawa
    Experimental Brain Research, 1998, 121 : 145 - 152
  • [40] LOCALIZING THE SITE OF MAGNETIC BRAIN-STIMULATION IN HUMANS
    EPSTEIN, CM
    SCHWARTZBERG, DG
    DAVEY, KR
    SUDDERTH, DB
    NEUROLOGY, 1990, 40 (04) : 666 - 670