Data processing approach for localizing bio-magnetic sources in the brain

被引:0
|
作者
Pai, Hung-, I [1 ]
Tseng, Chih-Yuan [1 ]
Lee, H. C. [1 ,2 ]
机构
[1] Natl Cent Univ, Dept Phys, Computat Biol Lab, Jhongli 320, Taiwan
[2] Natl Cent Univ, Grad Inst Syst Biol & Bioinformat, Jhongli 320, Taiwan
来源
NOISE AND FLUCTUATIONS | 2007年 / 922卷
关键词
MEG; ill-posed inverse problem; cluster; maximum entropy;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Magnetoencephalography (MEG) provides dynamic spatial-temporal insight for neural activities in the cortex. Because the possible number of sources is far greater than the number of MEG detectors, the proposition to localize sources directly from MEG data is ill-posed. Here we develop a novel approach based on a sequence of data processing procedures that includes a clustering process, an intersection analysis, and an application of the maximum entropy method. We examine the performance of our method and compare it with the minimum-norm least-square inverse method using an artificial noisy MEG data.
引用
收藏
页码:701 / +
页数:3
相关论文
共 50 条
  • [21] AN INTEGRATED CHIP COIL SENSOR AND INSTRUMENTATION AMPLIFIER FOR BIO-MAGNETIC SIGNAL ACQUISITION
    Nair, Vijith Vijayakumaran
    Youn, Jin Hwan
    Choi, Jun Rim
    2015 TRANSDUCERS - 2015 18TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), 2015, : 1581 - 1584
  • [22] Signal-to-noise improvement of bio-magnetic signals using a flux-gate probe and real time signal processing
    Dolabdjian, C
    Saez, S
    Toledo, AR
    Robbes, D
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (10): : 3678 - 3680
  • [23] Bio-Magnetic/Eddy-Current Sensor Design for Biological Object Detection
    Lin, Chun-Yeon
    Wu, Yi-Chin
    Chen, Yuan-Liang
    Huang, Shih-Cheng
    2020 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2020, : 18 - 23
  • [24] Experimenting with a robotic system for localizing magnetic field sources
    Amigoni, F
    Cadonici, S
    Caglioti, V
    Fontana, G
    PROCEEDINGS OF THE 2005 IEEE INTERNATIONAL CONFERENCE ON VIRTUAL ENVIRONMENTS, HUMAN-COMPUTER INTERFACES AND MEASUREMENT SYSTEMS, 2005, : 44 - 49
  • [25] Bio-Magnetic Sensor Circuit Design Based on Giant Magneto-Impedance Effect
    Wang, Zhihua
    Xu, Ming
    Xu, Xiaohong
    Zhou, Zongtan
    2016 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2016, : 2209 - 2214
  • [26] Numerical investigations of bio-magnetic blood flow through an artery in the presence of inflamed stenosis
    Tufail, Asma
    ul Islam, Shams
    Yasmeen, Shagufta
    Saleem, M.
    Ahmad, Shafee
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2023, 147
  • [27] Compact multi-channel optically pumped magnetometer for bio-magnetic field imaging
    Yuan, Ziqi
    Liu, Ying
    Xiang, Min
    Gao, Yang
    Suo, Yuchen
    Ye, Mao
    Zhai, Yueyang
    OPTICS AND LASER TECHNOLOGY, 2023, 164
  • [28] Localizing focal current sources from MEG data based on state-space approach
    Fukushima, Makoto
    Yamashita, Okito
    Kanemura, Atsunori
    Ishii, Shin
    Kawato, Mitsuo
    Sato, Masa-aki
    NEUROSCIENCE RESEARCH, 2011, 71 : E290 - E290
  • [29] A novel bio-controller for localizing pollution sources in a medium peclet environment
    John Oyekan
    Huosheng Hu
    Journal of Bionic Engineering, 2010, 7 : 345 - 353
  • [30] A Novel Bio-Controller for Localizing Pollution Sources in a Medium Peclet Environment
    John Oyekan
    Huosheng Hu
    Journal of Bionic Engineering, 2010, 7 (04) : 345 - 353