Comparison of retinal nerve fiber layer measured by time domain and spectral domain optical coherence tomography in optic neuritis

被引:10
|
作者
Rebolleda, G. [1 ]
Garcia-Garcia, A. [1 ]
Kim, H. R. Won [1 ]
Munoz-Negrete, F. J. [1 ]
机构
[1] Hosp Ramon & Cajal, Dept Ophthalmol, Glaucoma Unit, E-28034 Madrid, Spain
关键词
time domain OCT; spectral domain OCT; optic neuritis; MULTIPLE-SCLEROSIS; AXONAL LOSS; THICKNESS; OCT; ATROPHY;
D O I
10.1038/eye.2010.206
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To study the relationship between retinal nerve fiber layer (RNFL) thickness measurements from time domain (Stratus) and spectral domain (Cirrus HD) optical coherence tomography (OCT) in subjects with optic neuritis. Methods A total of 18 patients who had suffered monocular acute optic neuritis were imaged by a single trained operator using the Stratus-OCT (fast RNFL scan mode) and Cirrus HD-OCT (optic disc cube mode) on the same day. The relationship between RNFL thickness measurements of the two OCTs (overall and by quadrants) were evaluated using intraclass correlation coefficient (ICC) and Bland-Altman plots. Comparisons between eyes having optic neuritis (ON-group) and fellow eyes (fellow-group) were assessed by a generalized estimating equation (GEE) regression model. Results For Stratus-OCT, the median average RNFL was 86.3 and 102 mu in the ON-group and in the fellow-group, respectively. For Cirrus-OCT, the corresponding measurements were 81 and 93 mu. Average RNFL thickness as determined by the two OCT devices was well correlated in the ON-group (rho = 0.906, P < 0.001) and in the fellow-group (rho = 0.702, P = 0.001). The median signal strength was significantly higher with Cirrus-OCT. Bland-Altman plots showed that Stratus RNFL measurements were larger than Cirrus-OCT, but smaller when average RNFL thickness was very thin (<= 56 mu). Conclusions Although the Cirrus-OCT and Stratus-OCT RNFL thickness measurements are well correlated in patients with optic neuritis, RNFL measurements cannot be directly compared. Clinicians should be aware that measurements are generally higher with Stratus-than with Cirrus-OCT. Eye (2011) 25, 233-238; doi:10.1038/eye.2010.206; published online 24 December 2010
引用
收藏
页码:233 / 238
页数:6
相关论文
共 50 条
  • [1] Comparison of retinal nerve fiber layer measured by time domain and spectral domain optical coherence tomography in optic neuritis
    G Rebolleda
    A García-García
    H R Won Kim
    F J Muñoz-Negrete
    [J]. Eye, 2011, 25 : 233 - 238
  • [2] Comparison of Retinal Nerve Fiber Layer Thickness Measured by Time Domain and Spectral Domain Optical Coherence Tomography in Optic Neuritis
    Rebolleda, G.
    Garcia-Garcia, A.
    Kim, H. -R. Won
    Munoz-Negrete, F. J.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [3] Comparison of Retinal Nerve Fiber Layer Measurements Using Time Domain and Spectral Domain Optical Coherence Tomography in Optic Nerve Head Drusen
    Guerrero Altares, L.
    Rebolleda Fernandez, G.
    Munoz Negrete, F. J.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [4] Comparison of Time Domain and Spectral Domain Optical Coherence Tomography in Retinal Nerve Fiber Layer Thickness Measurements
    Bhartiya, S.
    Kumar, M.
    Kumar, V.
    Khanduja, S.
    Mishra, S. K.
    Dada, T.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [5] Comparison of Spectral Domain Retinal Nerve Fiber Layer Thickness and Agreement with Time Domain Optical Coherence Tomography
    Seibold, L.
    Mandava, N.
    Kahook, M. Y.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [6] Retinal Nerve Fiber Layer Measurements in Myopic Eyes as Measured by Time Domain and Spectral Domain Optical Coherence Tomography
    Choi, J.
    Lee, J.
    Kim, Y. -D.
    Choi, J.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [7] Agreement of predicted and measured retinal nerve fiber layer thickness from spectral domain and time domain optical coherence tomography
    Laemmer, Robert
    Schrems, Wolfgang A.
    Schrems-Hoesl, Laura M.
    Horn, Folkert K.
    Kruse, Friedrich E.
    Mardin, Christian Y.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [8] Comparison of Peripapillary Retinal Nerve Fiber Layer Thickness Measured by Spectral vs. Time Domain Optical Coherence Tomography
    Hong, Samin
    Seong, Gong Je
    Kim, Sung Soo
    Kang, Sung Yong
    Kim, Chan Yun
    [J]. CURRENT EYE RESEARCH, 2011, 36 (02) : 125 - 134
  • [9] Predicted and Measured Retinal Nerve Fiber Layer Thickness From Time-Domain Optical Coherence Tomography Compared With Spectral-Domain Optical Coherence Tomography
    Schrems, Wolfgang A.
    Schrems-Hoesl, LauraM.
    Bendschneider, Delia
    Mardin, Christian Y.
    Laemmer, Robert
    Kruse, Friedrich E.
    Horn, Folkert K.
    [J]. JAMA OPHTHALMOLOGY, 2015, 133 (10) : 1135 - 1143
  • [10] Predictors of Normal Optic Nerve Head, Retinal Nerve Fiber Layer, and Macular Parameters Measured by Spectral Domain Optical Coherence Tomography
    Rao, Harsha L.
    Kumar, Addepalli U.
    Babu, Jonnadula G.
    Kumar, Anjul
    Senthil, Sirisha
    Garudadri, Chandra S.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (02) : 1103 - 1110