Comparison of Peripapillary Retinal Nerve Fiber Layer Thickness Measured by Spectral vs. Time Domain Optical Coherence Tomography

被引:12
|
作者
Hong, Samin [1 ]
Seong, Gong Je [1 ]
Kim, Sung Soo [1 ]
Kang, Sung Yong [1 ]
Kim, Chan Yun [1 ]
机构
[1] Yonsei Univ, Coll Med, Dept Ophthalmol, Inst Vis Res, Seoul 120752, South Korea
关键词
Glaucoma; Optical coherence tomography; Retinal nerve fiber layer; Spectral-domain; Time-domain; SIGNAL STRENGTH; STRATUS OCT; GLAUCOMA; AGREEMENT; DEFINITION; SPEED;
D O I
10.3109/02713683.2010.533807
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Patients and Methods: One hundred and eighty-eight subjects (normal tension glaucoma, n == 80; primary open angle glaucoma, n == 49; healthy controls, n == 59) were included in this study. Peripapillary RNFL thickness was measured by an Optic Disc Cube 200 xx 200 scan of the spectral domain Cirrus HD OCT and by a Fast RNFL scan of the time domain Stratus OCT. They were compared using linear regression (R<SU2</SU), Bland-Altman plots, weighted Kappa (K-w) coefficients, and areas under the receiver operating characteristic curve (AROC). Results: Except for the inferior quadrant, RNFL thickness measurements by Cirrus HD OCT were thinner than Stratus OCT (all p < 0.001); for the inferior quadrant, this tendency was vice versa (p == 0.043). Average RNFL thicknesses of the two OCTs showed a good correlation (R<SU2</SU, 0.852) but not excellent agreement (mean of difference, 4.0 mu mu m; ++1.96 SD, 10.7 mu mu m; -1.96 SD, -18.6 mu mu m). Regarding the probability codes, only the average RNFL thickness had almost perfect agreement (K-w, 0.983). In addition, Cirrus HD OCT had the largest AROC for the superior quadrant (0.795), but Stratus OCT had the largest AROC for average RNFL thickness (0.764) (p == 0.281). Conclusions: Except for the inferior quadrant, the average and quadrants RNFL thickness measured by the Cirrus HD OCT were thinner than the Stratus OCT. Regarding discriminating power for glaucoma detection, the Cirrus HD OCT was better than the Stratus OCT for the superior and inferior quadrant RNFL thicknesses but not for the average RNFL thickness.
引用
收藏
页码:125 / 134
页数:10
相关论文
共 50 条
  • [1] Comparison of Spectral Domain Optical Coherence Tomography in the Measurement of Peripapillary Retinal Nerve Fiber Layer Thickness
    Calvo, P.
    Ferreras, A.
    Gil-Arribas, L.
    Pajarin, A.
    Pablo, L. E.
    Fuertes, M. I.
    Larrosa, J. M.
    Abadia, B.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [2] Comparison of Retinal Nerve Fiber Layer Thickness Measured by Time Domain and Spectral Domain Optical Coherence Tomography in Optic Neuritis
    Rebolleda, G.
    Garcia-Garcia, A.
    Kim, H. -R. Won
    Munoz-Negrete, F. J.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [3] Comparison of Peripapillary Retinal Nerve Fiber Layer Thickness Measured by Cirrus and Stratus Optical Coherence Tomography
    Gil-Arribas, L.
    Ferreras, A.
    Caivo, P.
    Pajarin, B.
    Pablo, L. E.
    Polo, V.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [4] Comparison of Time Domain and Spectral Domain Optical Coherence Tomography in Retinal Nerve Fiber Layer Thickness Measurements
    Bhartiya, S.
    Kumar, M.
    Kumar, V.
    Khanduja, S.
    Mishra, S. K.
    Dada, T.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [5] Comparison of Spectral Domain Retinal Nerve Fiber Layer Thickness and Agreement with Time Domain Optical Coherence Tomography
    Seibold, L.
    Mandava, N.
    Kahook, M. Y.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [6] Comparison of retinal nerve fiber layer measured by time domain and spectral domain optical coherence tomography in optic neuritis
    G Rebolleda
    A García-García
    H R Won Kim
    F J Muñoz-Negrete
    [J]. Eye, 2011, 25 : 233 - 238
  • [7] Comparison of retinal nerve fiber layer measured by time domain and spectral domain optical coherence tomography in optic neuritis
    Rebolleda, G.
    Garcia-Garcia, A.
    Kim, H. R. Won
    Munoz-Negrete, F. J.
    [J]. EYE, 2011, 25 (02) : 233 - 238
  • [8] Agreement of predicted and measured retinal nerve fiber layer thickness from spectral domain and time domain optical coherence tomography
    Laemmer, Robert
    Schrems, Wolfgang A.
    Schrems-Hoesl, Laura M.
    Horn, Folkert K.
    Kruse, Friedrich E.
    Mardin, Christian Y.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [9] Retinal Nerve Fiber Layer Thickness Measured by Spectral Domain Optical Coherence Tomography in Healthy Koreans
    Choi, Youna
    Cho, Byung Joo
    [J]. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2018, 59 (06): : 537 - 542
  • [10] Peripapillary retinal nerve fiber layer thickness measurement by 2 different spectral domain optical coherence tomography machines
    Pakravan, Mohammad
    Pakbin, Mojgan
    Aghazadehamiri, Mohammad
    Yazdani, Shahin
    Yaseri, Mehdi
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2013, 23 (03) : 289 - 295