Electronic measurement of cell antigen expression in whole blood

被引:6
|
作者
Civelekoglu, Ozgun [1 ]
Liu, Ruxiu [1 ]
Usanmaz, Can F. [1 ]
Chu, Chia-Heng [1 ]
Boya, Mert [1 ]
Ozkaya-Ahmadov, Tevhide [1 ]
Arifuzzman, A. K. M. [1 ]
Wang, Ningquan [1 ]
Sarioglu, A. Fatih [1 ,2 ,3 ]
机构
[1] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Parker H Petit Inst Bioengn & Biosci, Atlanta, GA 30332 USA
[3] Georgia Inst Technol, Inst Elect & Nanotechnol, Atlanta, GA 30332 USA
基金
美国国家科学基金会;
关键词
FLOW-CYTOMETRY; PROGENITOR CELLS; DISEASE; PRINCIPLES; MOLECULES; HISTOGRAM; NETWORKS; DENSITY; MARKERS; RISK;
D O I
10.1039/d1lc00889g
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Membrane antigens are phenotypic signatures of cells used for distinguishing various subpopulations and, therefore, are of great interest for diagnosis of diseases and monitoring of patients in hematology and oncology. Existing methods to measure antigen expression of a target subpopulation in blood samples require labor-intensive lysis of contaminating cells and subsequent analysis with complex and bulky instruments in specialized laboratories. To address this long-standing limitation in clinical cytometry, we introduce a microchip-based technique that can directly measure surface expression of target cells in hematological samples. Our microchip isolates an immunomagnetically-labeled target cell population from the contaminating background in whole blood and then utilizes the differential responses of target cells to on-chip magnetic manipulation to estimate their antigen expression. Moreover, manipulating cells with chip-sized permanent magnets and performing quantitative measurements via an on-chip electrical sensor network allows the assay to be performed in a portable platform with no reliance on laboratory infrastructure. Using our technique, we could successfully measure expressions of the CD45 antigen that is commonly expressed by white blood cells, as well as CD34 that is expressed by scarce hematopoietic progenitor cells, which constitutes only similar to 0.0001% of all blood cells, directly from whole blood. With our technology, flow cytometry can potentially become a rapid bedside or at-home testing method that is available around the clock in environments where this invaluable assay with proven clinical utility is currently either outsourced or not even accessible.
引用
收藏
页码:296 / 312
页数:17
相关论文
共 50 条
  • [21] On the accurate measurement of serotonin in whole blood
    Xiao, R
    Beck, O
    Hjemdahl, P
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1998, 58 (06): : 505 - 510
  • [22] Sensitive and quantitative measurement of gene expression directly from a small amount of whole blood
    Zheng, Z
    Luo, YL
    McMaster, GK
    CLINICAL CHEMISTRY, 2006, 52 (07) : 1294 - 1302
  • [23] Detection and measurement of a single blood cell surface antigen by thermal lens microscopy
    Kimura, H
    Nagao, F
    Kitamura, A
    Sekiguchi, K
    Kitamori, T
    Sawada, T
    ANALYTICAL BIOCHEMISTRY, 2000, 283 (01) : 27 - 32
  • [24] Whole-blood CCR7 expression and chemoattraction in red blood cell alloimmunization
    Tamagne, Marie
    Pakdaman, Sadaf
    Bartolucci, Pablo
    Habibi, Anoosha
    Galacteros, Frederic
    Pirenne, France
    Vingert, Benoit
    BRITISH JOURNAL OF HAEMATOLOGY, 2021, 194 (02) : 477 - 481
  • [25] Differential cytokine mRNA expression in swine whole blood and peripheral blood mononuclear cell cultures
    Yancy, H
    Ayers, SL
    Farrell, DE
    Day, A
    Myers, MJ
    VETERINARY IMMUNOLOGY AND IMMUNOPATHOLOGY, 2001, 79 (1-2) : 41 - 52
  • [26] A physiometer for simultaneous measurement of whole blood viscosity and its determinants: hematocrit and red blood cell deformability
    Kim, Byung Jun
    Lee, Ye Sung
    Zhbanov, Alexander
    Yang, Sung
    ANALYST, 2019, 144 (09) : 3144 - 3157
  • [27] Expression of Lutheran Antigen (LU), a red blood cell surface antigen, in the rat nervous system.
    Taira, E
    Kohama, K
    Okumura, S
    Miki, N
    JOURNAL OF PHARMACOLOGICAL SCIENCES, 2003, 91 : 116P - 116P
  • [28] Importance of platelets in expression of monocyte tissue factor antigen measured by flow cytometry in whole blood.
    Amirkhosravi, A
    Alexander, M
    Warnes, G
    Biggerstaff, J
    May, K
    Francis, DA
    Francis, JL
    BLOOD, 1995, 86 (10) : 298 - 298
  • [29] Comparison of different methods for telomere length measurement in whole blood and blood cell subsets: Recommendations for telomere length measurement in hematological diseases
    Behrens, Yvonne Lisa
    Thomay, Kathrin
    Hagedorn, Maike
    Ebersold, Juliane
    Henrich, Lea
    Nustede, Rainer
    Schlegelberger, Brigitte
    Goehring, Gudrun
    GENES CHROMOSOMES & CANCER, 2017, 56 (09): : 700 - 708
  • [30] Automatic measurement of the red cell oxygen dissociation curve identical with the whole blood curve
    Mawjood, AHM
    Imai, K
    JAPANESE JOURNAL OF PHYSIOLOGY, 1999, 49 (04): : 379 - 387