Retrospective analysis of 2D patient-specific IMRT verifications

被引:31
|
作者
Childress, NL
White, RA
Bloch, C
Salehpour, M
Dong, L
Rosen, II
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas, MD Anderson Canc Ctr, Dept Biostat, Houston, TX 77030 USA
关键词
D O I
10.1118/1.1879272
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We performed 858 two-dimensional (2D) patient-specific intensity modulated radiotherapy verifications over a period of 18 months. Multifield, composite treatment plans were measured in phantom using calibrated Kodak EDR2 film and compared with the calculated dose extracted from two treatment planning systems. This research summarizes our findings using the normalized agreement test (NAT) index and the percent of pixels failing the gamma index as metrics to represent the agreement between measured and computed dose distributions. An in-house dose comparison software package was used to register and compare all verifications. We found it was important to use an automatic positioning algorithm to achieve maximum registration accuracy, and that our automatic algorithm agreed well with anticipated results from known phantom geometries. We also measured absolute dose for each case using an ion chamber. Because the computed distributions agreed with ion chamber measurements better than the EDR2 film doses, we normalized EDR2 data to the computed distributions. The distributions of both the NAT indices and the percentage of pixels failing the gamma index were found to be exponential distributions. We continue to use both the NAT index and percent of pixels failing gamma with 5%/3 mm criteria to evaluate future verifications, as these two metrics were found to be complementary. Our data showed that using 2%/2 mun or 3%/3 mm criteria produces results similar to those using 5%/3 mm criteria. Normalized comparisons that have a NAT index greater than 45 and/or more than 20% of the pixels failing gamma for 5%/3 mm criteria represent outliers from our clinical data set and require further analysis. Because our QA verification results were exponentially distributed, rather than a tight grouping of similar results, we continue to perform patient-specific QA in order to identify and correct outliers in our verifications. The data from this work could be useful as a reference for other clinics to indicate anticipated trends in 2D verifications under various conditions. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:838 / 850
页数:13
相关论文
共 50 条
  • [1] 2D dose reconstruction of IMRT patient-specific QA based on log file
    Mubarok, Sayid
    Wahyu, Wibowo Edy
    Supriyanto, Pawiro Ardjo
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2020, 166
  • [2] Curtailing patient-specific IMRT QA procedures from 2D dose error distribution
    Kurosu, Keita
    Sumida, Iori
    Mizuno, Hirokazu
    Otani, Yuki
    Oda, Michio
    Isohashi, Fumiaki
    Seo, Yuji
    Suzuki, Osamu
    Ogawa, Kazuhiko
    [J]. JOURNAL OF RADIATION RESEARCH, 2016, 57 (03) : 258 - 264
  • [3] Quantitative analysis of patient-specific dosimetric IMRT verification
    Budgell, GJ
    Perrin, BA
    Mott, JHL
    Fairfoul, J
    Mackay, RI
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (01): : 103 - 119
  • [4] Implementation of 2D Arrays for TomoTherapy Patient-Specific QA
    Winningham, T.
    Staton, R.
    Meeks, S.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [5] Reproducibility in patient-specific IMRT QA
    McKenzie, Elizabeth M.
    Balter, Peter A.
    Stingo, Francesco C.
    Jones, Jimmy
    Followill, David S.
    Kry, Stephen F.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (03): : 241 - 251
  • [6] On the Influences of the Detector Size and Sampling Frequency On IMRT Verifications with 2D Arrays
    Poppe, B.
    Djouguela, A.
    Heidorn, S.
    Ruehmann, A.
    Willborn, K.
    Harder, D.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [7] A statistical approach to IMRT patient-specific QA
    Palaniswaamy, Geethpriya
    Brame, Ryan Scott
    Yaddanapudi, Sridhar
    Rangaraj, Dharanipathy
    Mutic, Sasa
    [J]. MEDICAL PHYSICS, 2012, 39 (12) : 7560 - 7570
  • [8] Comparison of 2D and 3D Gamma Analysis in Patient-Specific QA for Prostate VMAT Plans
    Clemente, F.
    Perez, C.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 240 - +
  • [9] A Review of Patient-specific IMRT QC at Guildford
    Rickard, D. J.
    Aldridge, S. E.
    Jordan, T. J.
    [J]. CLINICAL ONCOLOGY, 2009, 21 (03) : 277 - 277
  • [10] Reproducibility in the Field of Patient-Specific IMRT QA
    McKenzie, E.
    Balter, P.
    Jones, J.
    Followill, D.
    Stingo, F.
    Kry, S.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)