Patient-specific dosimetric verification methods for IMRT treatments are variable, time-consuming and frequently qualitative, preventing evidence-based reduction in the amount of verification performed. This paper addresses some of these issues by applying a quantitative analysis parameter to the dosimetric verification procedure. Film measurements in different planes were acquired for a series of ten IMRT prostate patients, analysed using the quantitative parameter, and compared to determine the most suitable verification plane. Film and ion chamber verification results for 61 patients were analysed to determine long-term accuracy, reproducibility and stability of the planning and delivery system. The reproducibility of the measurement and analysis system was also studied. The results show that verification results are strongly dependent on the plane chosen, with the coronal plane particularly insensitive to delivery error. Unexpectedly, no correlation could be found between the levels of error in different verification planes. Longer term verification results showed consistent patterns which suggest that the amount of patient-specific verification can be safely reduced, provided proper caution is exercised: an evidence-based model for such reduction is proposed. It is concluded that dose/distance to agreement (e.g., 3%/3 mm) should be used as a criterion of acceptability. Quantitative parameters calculated for a given criterion of acceptability should be adopted in conjunction with displays that show where discrepancies occur. Planning and delivery systems which cannot meet the required standards of accuracy, reproducibility and stability to reduce verification will not be accepted by the radiotherapy community.
引用
收藏
页码:103 / 119
页数:17
相关论文
共 50 条
  • [1] Quantitative dosimetric verification for IMRT
    Narita, Y
    Hatano, K
    Sakai, M
    Araki, H
    [J]. RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S105 - S105
  • [2] A systematic approach to statistical analysis in dosimetry and patient-specific IMRT plan verification measurements
    Qin, Songbing
    Zhang, Miao
    Kim, Sung
    Chen, Ting
    Kim, Leonard H.
    Haffty, Bruce G.
    Yue, Ning J.
    [J]. RADIATION ONCOLOGY, 2013, 8
  • [3] A systematic approach to statistical analysis in dosimetry and patient-specific IMRT plan verification measurements
    Songbing Qin
    Miao Zhang
    Sung Kim
    Ting Chen
    Leonard H Kim
    Bruce G Haffty
    Ning J Yue
    [J]. Radiation Oncology, 8
  • [4] Patient-specific point dose measurement for IMRT monitor unit verification
    Dong, L
    Antolak, J
    Salehpour, M
    Forster, K
    O'Neill, L
    Kendall, R
    Rosen, I
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (03): : 867 - 877
  • [5] Quantitative dosimetric verification of an IMRT planning and delivery system
    Low, DA
    Mutic, S
    Dempsey, JF
    Gerber, RL
    Bosch, WR
    Perez, CA
    Purdy, JA
    [J]. RADIOTHERAPY AND ONCOLOGY, 1998, 49 (03) : 305 - 316
  • [6] Patient-specific IMRT QA verification using machine learning and gamma radiomics
    Lizar, Jessica Caroline
    Yaly, Carolina Cariolatto
    Bruno, Alexandre Colello
    Viani, Gustavo Arruda
    Pavoni, Juliana Fernandes
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 82 : 100 - 108
  • [7] Reproducibility in patient-specific IMRT QA
    McKenzie, Elizabeth M.
    Balter, Peter A.
    Stingo, Francesco C.
    Jones, Jimmy
    Followill, David S.
    Kry, Stephen F.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (03): : 241 - 251
  • [8] Dosimetric comparison of patient-specific margins Vs. uniform margins for prostate IMRT treatments
    Yoo, S.
    Das, S.
    Kim, S.
    Koontz, B.
    Lee, W.
    Light, K.
    Yin, F.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2383 - 2383
  • [9] Verification and documentation for patient-specific IMRT QA using varis and portal vision systems
    Nurushev, T
    Kim, J
    Yin, FF
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1501 - 1501
  • [10] IMRT DOSIMETRIC VERIFICATION PROCEDURE
    Pellejero, S.
    Lozares, S.
    Forner, A.
    Iriondo, U.
    Otal, A.
    Soto, P. M.
    Maneru, F.
    Martin-Albina, M. L.
    Miquelez, S.
    Rubio, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S512 - S512