A statistical approach to IMRT patient-specific QA

被引:22
|
作者
Palaniswaamy, Geethpriya [1 ]
Brame, Ryan Scott [1 ]
Yaddanapudi, Sridhar [1 ]
Rangaraj, Dharanipathy [1 ]
Mutic, Sasa [1 ]
机构
[1] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO 63110 USA
关键词
intensity modulated radiation therapy (IMRT); quality assurance (QA); analysis of variance (ANOVA); statistical process control (SPC); QUALITY-ASSURANCE; RADIOTHERAPY; VERIFICATION; DELIVERY;
D O I
10.1118/1.4768161
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The intensity modulated radiation therapy (IMRT) patient-specific quality assurance (QA) (referred to as QA in this paper for simplicity) process is a time and resource intensive effort in every clinic. The use of a global QA tolerance criterion for all treatment sites may be too tight for some complex sites increasing false negatives and rejections of QA measurements which typically results in wasted efforts, treatment delays, and decreased efficiency. At the same time, other sites requiring a less complex plan might have a high false positive leading to approvals of QA measurements that actually need to be rejected. This work is an effort to adopt statistical tools to 1. develop a tool to identify statistical variations in the process, monitor trends, detect outliers, and proactively identify drifts in the overall QA results; 2. analyze the results of the QA process, identify similarities and differences between treatment plans of different treatment sites, and evaluate the possibility of site-specific tolerance levels for QA approval tolerances. Methods: The analysis was performed for QA measurements made using two ion chamber points. A custom software tool was developed for data processing and analysis. This tool facilitated QA data collection, retrieval, visualization, real-time feedback, and advanced statistical analysis of the data. Statistical techniques based on analysis of variance were used to evaluate the need for site-specific tolerances and statistical process control was used to study statistical variations in the process. Results: A retrospective analysis of the QA process variability was performed in order to identify site-specific tolerances for the QA measurements and to reduce false positive and false negative QA results. From the data, it can be seen that the treatment sites are significantly different and need site-specific tolerance levels for QA approval. The in-house developed tool was used to further monitor the QA process using individual (I), standard deviations (S), and exponentially weighted moving averages charts for process variability studies. Conclusions: The authors have studied the analysis of variance on ion chamber measurements made for IMRT treatment plans on different sites, identified similarities and differences between different sites, and thereby evaluated the need for site-specific tolerances for QA acceptance policy. The authors have proposed a way to calculate the appropriate tolerances for different treatment sites and illustrated the clinical usage. Variability at each step of the process increases the uncertainty in the process. The authors have explained the different approaches taken to reduce the variability at each step of the entire process. This process can be used for the benefit during/as part of an IMRT commissioning process in any clinic. The authors have also developed a tool to automate the process of data collection, analysis, and monitoring the process quality via standard deviations and EWMA charts. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4768161]
引用
下载
收藏
页码:7560 / 7570
页数:11
相关论文
共 50 条
  • [1] Reproducibility in patient-specific IMRT QA
    McKenzie, Elizabeth M.
    Balter, Peter A.
    Stingo, Francesco C.
    Jones, Jimmy
    Followill, David S.
    Kry, Stephen F.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (03): : 241 - 251
  • [2] Statistical process control analysis for patient-specific IMRT and VMAT QA
    Sanghangthum, Taweap
    Suriyapee, Sivalee
    Srisatit, Somyot
    Pawlicki, Todd
    JOURNAL OF RADIATION RESEARCH, 2013, 54 (03) : 546 - 552
  • [3] Reproducibility in the Field of Patient-Specific IMRT QA
    McKenzie, E.
    Balter, P.
    Jones, J.
    Followill, D.
    Stingo, F.
    Kry, S.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [4] The limitation of patient-specific QA in IMRT with detector arrays
    Huh, S.
    Cho, W.
    Park, Y.
    MEDICAL PHYSICS, 2006, 33 (06) : 2143 - 2143
  • [5] Developing a comprehensive patient-specific QA procedure for IMRT
    Luo, W.
    Li, J.
    Price, R.
    Chen, L.
    Fan, J.
    Chen, Z.
    Lin, T.
    Wang, L.
    Ma, C.
    MEDICAL PHYSICS, 2006, 33 (06) : 2247 - 2248
  • [6] On the sensitivity of patient-specific IMRT QA to MLC positioning errors
    Yan, Guanghua
    Liu, Chihray
    Simon, Thomas A.
    Peng, Lee-Cheng
    Fox, Christopher
    Li, Jonathan G.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (01): : 120 - 128
  • [7] On the Sensitivity of Patient-Specific IMRT QA to MLC Position Errors
    Yan, G.
    Simon, T.
    Peng, L.
    Fox, C.
    Liu, C.
    Li, J.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [8] Eliminating Errors in Setup and Positioning for Patient-Specific IMRT QA
    Kamath, S.
    Palta, J.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [9] On the use of biomathematical models in patient-specific IMRT dose QA
    Zhen, Heming
    Nelms, Benjamin E.
    Tome, Wolfgang A.
    MEDICAL PHYSICS, 2013, 40 (07)
  • [10] Continuous Quality Improvement for Patient-Specific IMRT/SBRT QA
    Boddu, S.
    Perks, J.
    MEDICAL PHYSICS, 2011, 38 (06)