Improvement in the quantification of myocardial perfusion using an automatic spline-based registration algorithm

被引:32
|
作者
Dornier, C
Ivancevic, MK
Thévenaz, P
Vallée, JP
机构
[1] Univ Hosp Geneva, Dept Radiol, Digital Imaging Unit, CH-1211 Geneva 14, Switzerland
[2] Ecole Polytech Fed Lausanne, Biomed Imaging Grp, Lausanne, Switzerland
关键词
image registration; respiratory motion correction; cardiac perfusion assessment; dynamic MRI; gated MRI;
D O I
10.1002/jmri.10351
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To improve the quantification of myocardial perfusion by registering the time series of magnetic resonance (MR) images with injection of gadolinium. Materials and Methods: Eight patients underwent MR scans to perform myocardial perfusion exam. Two short axis views of the left ventricle (LV) were acquired in free breathing. Two masks for performing the spatial registration of the images were evaluated. The registration was based on pixel intensity in a multi-resolution scheme. The efficiency of this correction was evaluated by calculating geometric residual displacement of the LV and by fitting the data to a compartment model fit with two parameters: K1, the blood-to-myocardium transfer coefficient, and Vd, the distribution volume of the contrast media. Results: The registration stage allowed a decrease in the observed motion of the LV from more than 1.98 +/- 0.68 mm to less than 0.56 +/- 0.18 rorn (mean +/- SD). Variability obtained in the perfusion analysis decreased from 46 103% to 5 +/- 4% for KI parameter and from 18 +/- 21% to 5 +/- 5% for Vd parameter. Conclusion: As with manual correction, this automatic motion correction leads to accurate perfusion parameters in dynamic cardiac MR imaging after contrast agent injection. This automatic stage requires placing only one mask over one frame of the perfusion study instead of manually shifting each image to fit a reference image of the perfusion study.
引用
收藏
页码:160 / 168
页数:9
相关论文
共 50 条
  • [21] Adaptive spline-based PLL for synchronisation and power quality improvement in distribution system
    Saxena, Hemant
    Singh, Alka
    Rai, Jitendra Nath
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (07) : 1311 - 1319
  • [22] Automatic motion correction for quantification of myocardial perfusion using dynamic magnetic resonance imaging
    Kawakami, K
    Murase, K
    Kawakami, A
    Kumashiro, M
    Yamazaki, Y
    Tabuchi, T
    Nagayama, M
    Watanabe, Y
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 1372 - 1372
  • [23] Using a registration-based motion correction algorithm to correct for respiratory motion during myocardial perfusion imaging
    Redgate, Shelley
    Barber, David C.
    Abdallah, Al-Mohammad
    Wendy, Tindale B.
    NUCLEAR MEDICINE COMMUNICATIONS, 2013, 34 (08) : 787 - 795
  • [24] Automatic Feature Based Image Registration Using SIFT Algorithm
    Mahesh
    Subramanyam, M., V
    2012 THIRD INTERNATIONAL CONFERENCE ON COMPUTING COMMUNICATION & NETWORKING TECHNOLOGIES (ICCCNT), 2012,
  • [25] Using a registration based motion correction algorithm (RMCA) to correct for respiratory motion during myocardial perfusion Imaging
    Redgate, S.
    Tindale, W. B.
    Barber, D. C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S146 - S146
  • [26] An Enhanced Image Compression Codec using Spline-based Directional LiftingWavelet Transform and an Improved SPIHT Algorithm
    Boujelbene, Rania
    Ben Jemaa, Yousra
    PROCEEDINGS OF THE 16TH INTERNATIONAL CONFERENCE ON SOFTWARE TECHNOLOGIES (ICSOFT), 2021, : 631 - 638
  • [27] Improvement of Shape Registration Using Free Form Deformations Based on B-spline
    Ban, Xiaojuan
    Liu, Xi
    Li, Guohui
    2015 IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION, 2015, : 1388 - 1392
  • [28] Automatic registration of MR first-pass myocardial perfusion images
    Bracoud, L
    Vincent, F
    Pachai, C
    Canet, E
    Croisille, P
    Revel, D
    FUNCTIONAL IMAGING AND MODELING OF THE HEART, PROCEEDINGS, 2003, 2674 : 215 - 223
  • [29] Reconstruction of a distribution from a finite number of moments with an adaptive spline-based algorithm
    de Souza, L. G. M.
    Janiga, G.
    John, V.
    Thevenin, D.
    CHEMICAL ENGINEERING SCIENCE, 2010, 65 (09) : 2741 - 2750
  • [30] Topology optimization based on spline-based meshfree method using topological derivatives
    Junyoung Hur
    Pilseong Kang
    Sung-Kie Youn
    Journal of Mechanical Science and Technology, 2017, 31 : 2423 - 2431