Improvement in the quantification of myocardial perfusion using an automatic spline-based registration algorithm

被引:32
|
作者
Dornier, C
Ivancevic, MK
Thévenaz, P
Vallée, JP
机构
[1] Univ Hosp Geneva, Dept Radiol, Digital Imaging Unit, CH-1211 Geneva 14, Switzerland
[2] Ecole Polytech Fed Lausanne, Biomed Imaging Grp, Lausanne, Switzerland
关键词
image registration; respiratory motion correction; cardiac perfusion assessment; dynamic MRI; gated MRI;
D O I
10.1002/jmri.10351
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To improve the quantification of myocardial perfusion by registering the time series of magnetic resonance (MR) images with injection of gadolinium. Materials and Methods: Eight patients underwent MR scans to perform myocardial perfusion exam. Two short axis views of the left ventricle (LV) were acquired in free breathing. Two masks for performing the spatial registration of the images were evaluated. The registration was based on pixel intensity in a multi-resolution scheme. The efficiency of this correction was evaluated by calculating geometric residual displacement of the LV and by fitting the data to a compartment model fit with two parameters: K1, the blood-to-myocardium transfer coefficient, and Vd, the distribution volume of the contrast media. Results: The registration stage allowed a decrease in the observed motion of the LV from more than 1.98 +/- 0.68 mm to less than 0.56 +/- 0.18 rorn (mean +/- SD). Variability obtained in the perfusion analysis decreased from 46 103% to 5 +/- 4% for KI parameter and from 18 +/- 21% to 5 +/- 5% for Vd parameter. Conclusion: As with manual correction, this automatic motion correction leads to accurate perfusion parameters in dynamic cardiac MR imaging after contrast agent injection. This automatic stage requires placing only one mask over one frame of the perfusion study instead of manually shifting each image to fit a reference image of the perfusion study.
引用
收藏
页码:160 / 168
页数:9
相关论文
共 50 条
  • [11] Multi-dimensional spline-based non-rigid image registration
    Viola, Francesco
    Guenther, Drake A.
    Coe, Ryan L.
    Walker, William F.
    MEDICAL IMAGING 2007: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2007, 6513
  • [12] A spline-based algorithm for continuous time-delay estimation using sampled data
    Viola, F
    Walker, WF
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (01) : 80 - 93
  • [13] Spline-based elastic image registration: integration of landmark errors and orientation attributes
    Rohr, K
    Fornefett, M
    Stiehl, HS
    COMPUTER VISION AND IMAGE UNDERSTANDING, 2003, 90 (02) : 153 - 168
  • [14] Registration of Cardiac Magnetic Resonance Perfusion Data as a Basis for Quantification of Myocardial Perfusion
    Kachenoura, N.
    Cluzel, P.
    Grenier, P.
    Cuenod, C. A.
    Frouin, F.
    Balvay, D.
    CINC: 2009 36TH ANNUAL COMPUTERS IN CARDIOLOGY CONFERENCE, 2009, 36 : 265 - +
  • [15] Automatic calculation of myocardial perfusion reserve using deep learning with uncertainty quantification
    Kim, Yoon-Chul
    Kim, Kyurae
    Choe, Yeon Hyeon
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (12) : 7936 - 7949
  • [16] New algorithm for quantification of myocardial perfusion SPECT
    Van Train, KF
    Garcia, EV
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (02) : 391 - 391
  • [17] Automated registration of dynamic MR images for the quantification of myocardial perfusion
    Bidaut, LM
    Vallée, JP
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (04) : 648 - 655
  • [18] Spline-based elastic image registration with matrix-valued basis functions using landmark and intensity information
    Woerz, Stefan
    Rohr, Karl
    PATTERN RECOGNITION, PROCEEDINGS, 2007, 4713 : 537 - +
  • [19] SCALE-BUNDLE SPLINE-BASED NON-RIGID REGISTRATION FOR HANDLING FISSURES
    Ali, Sharib
    Amunts, Katrin
    Eils, Roland
    Axer, Markus
    Rohr, Karl
    2018 IEEE 15TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2018), 2018, : 762 - 765
  • [20] Spline-based image-to-volume registration for three-dimensional electron microscopy
    Jonic, S
    Sorzano, COS
    Thévenaz, P
    El-Bez, C
    De Carlo, S
    Unser, M
    ULTRAMICROSCOPY, 2005, 103 (04) : 303 - 317