Improvement in the quantification of myocardial perfusion using an automatic spline-based registration algorithm

被引:32
|
作者
Dornier, C
Ivancevic, MK
Thévenaz, P
Vallée, JP
机构
[1] Univ Hosp Geneva, Dept Radiol, Digital Imaging Unit, CH-1211 Geneva 14, Switzerland
[2] Ecole Polytech Fed Lausanne, Biomed Imaging Grp, Lausanne, Switzerland
关键词
image registration; respiratory motion correction; cardiac perfusion assessment; dynamic MRI; gated MRI;
D O I
10.1002/jmri.10351
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To improve the quantification of myocardial perfusion by registering the time series of magnetic resonance (MR) images with injection of gadolinium. Materials and Methods: Eight patients underwent MR scans to perform myocardial perfusion exam. Two short axis views of the left ventricle (LV) were acquired in free breathing. Two masks for performing the spatial registration of the images were evaluated. The registration was based on pixel intensity in a multi-resolution scheme. The efficiency of this correction was evaluated by calculating geometric residual displacement of the LV and by fitting the data to a compartment model fit with two parameters: K1, the blood-to-myocardium transfer coefficient, and Vd, the distribution volume of the contrast media. Results: The registration stage allowed a decrease in the observed motion of the LV from more than 1.98 +/- 0.68 mm to less than 0.56 +/- 0.18 rorn (mean +/- SD). Variability obtained in the perfusion analysis decreased from 46 103% to 5 +/- 4% for KI parameter and from 18 +/- 21% to 5 +/- 5% for Vd parameter. Conclusion: As with manual correction, this automatic motion correction leads to accurate perfusion parameters in dynamic cardiac MR imaging after contrast agent injection. This automatic stage requires placing only one mask over one frame of the perfusion study instead of manually shifting each image to fit a reference image of the perfusion study.
引用
收藏
页码:160 / 168
页数:9
相关论文
共 50 条
  • [1] Spline-Based Image Registration
    Richard Szeliski
    James Coughlan
    International Journal of Computer Vision, 1997, 22 : 199 - 218
  • [2] Spline-based image registration
    Szeliski, R
    Coughlan, J
    INTERNATIONAL JOURNAL OF COMPUTER VISION, 1997, 22 (03) : 199 - 218
  • [3] Algorithm for spline-based elastic registration in application to confocal images of gene expression
    Sorzano C.O.S.
    Blagov M.S.
    Thévenaz P.
    Myasnikova E.M.
    Samsonova M.G.
    Unser M.
    Pattern Recognition and Image Analysis, 2006, 16 (1) : 93 - 96
  • [4] Spline-based elastic image registration using solutions of the navier equation
    Woerz, Stefan
    Rohr, Karl
    MEDICAL IMAGING 2007: IMAGE PROCESSING, PTS 1-3, 2007, 6512
  • [5] Spline-based automatic path generation of welding robot
    牛雪娟
    李亮玉
    China Welding, 2007, (04) : 27 - 31
  • [6] Localizing Against Drawn Maps via Spline-Based Registration
    Chen, Kevin
    Vazquez, Marynel
    Savarese, Silvio
    2020 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS), 2020, : 8521 - 8526
  • [7] A spline-based non-linear diffeomorphism for multimodal prostate registration
    Mitra, Jhimli
    Kato, Zoltan
    Marti, Robert
    Oliver, Arnau
    Llado, Xavier
    Sidibe, Desire
    Ghose, Soumya
    Vilanova, Joan C.
    Comet, Josep
    Meriaudeau, Fabrice
    MEDICAL IMAGE ANALYSIS, 2012, 16 (06) : 1259 - 1279
  • [8] Hybrid Spline-Based Multimodal Registration Using Local Measures for Joint Entropy and Mutual Information
    Biesdorf, Andreas
    Woerz, Stefan
    Kaiser, Hans-Juergen
    Stippich, Christoph
    Rohr, Karl
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2009, PT I, PROCEEDINGS, 2009, 5761 : 607 - +
  • [9] Automatic reorientation algorithm for myocardial perfusion SPECT using segmentation
    Vijande, Ezequiel
    Campisi, Roxana
    Juarez-Orozco, Luis Eduardo
    Aguero, Roberto
    Geronazzo, Ricardo
    Namias, Mauro
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2025, 55
  • [10] A Novel Spline-Based Algorithm for Multidimensional Displacement and Strain Estimation
    Walker, William F.
    Guenther, Drake A.
    Coe, Ryan L.
    Viola, Francesco