Technical Note: Optimal sampling schedules for kidney dosimetry based on the hybrid planar/SPECT method in 177Lu-PSMA therapy

被引:13
|
作者
Rinscheid, Andreas [1 ,2 ]
Kletting, Peter [1 ,2 ]
Eiber, Matthias [3 ]
Beer, Ambros J. [1 ]
Glatting, Gerhard [1 ,2 ]
机构
[1] Ulm Univ, Dept Nucl Med, Med Radiat Phys, D-89081 Ulm, Germany
[2] Ulm Univ, Dept Nucl Med, D-89081 Ulm, Germany
[3] Tech Univ Munich, Klinikum Rechts Isar, Dept Nucl Med, D-81675 Munich, Germany
关键词
Lu-177-PSMA; dosimetry; optimal sampling schedules; radioligand therapy; I-AND-T; SOFTWARE; TUMOR; SPECT;
D O I
10.1002/mp.13846
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Accurate and precise renal dosimetry during Lu-177-labeled prostate-specific membrane antigen (PSMA) radioligand therapy is crucial for therapy decisions. Sampling schedules for estimating the necessary time-integrated activity coefficients (TIACs) are not optimized and standardized for clinical practice. Therefore, a simulation study to determine optimal sampling schedules (OSSs) was performed on 13 virtual Lu-177-PSMA I&T therapy patients. Method A total of 880 clinically feasible sampling schedules for planar imaging (three time points) were investigated. To simulate the hybrid planar/SPECT method, an additional quantitative SPECT/CT measurement following one planar image was considered. For each sampling schedule and patient, the activity values were generated separately. Measurement noise was modeled by drawing random numbers of log-normal distributions. The used fractional standard deviations (FSD) differed depending on the imaging modality. For activity values assigned to planar imaging, systematic noise between 25% and 75% of the total noise was simulated. After fitting with a mono-exponential function, the root-mean-squared errors of the deviations of the simulated TIACs from the ground truth for 1000 replications were used to determine the OSS. The uncertainties of the TIACs and renal dose coefficients were estimated. Results For the hybrid planar/SPECT method, OSSs were determined to be (3-4, 72-76, 124-144) h post injection (p.i.) with the quantitative SPECT/CT scan shortly after the second measurement. The accuracy and precision of the determined TIACs were in the range of (-3.0 +/- 6.2)% and (-1.0 +/- 6.5)%. This precision was improved by a factor 2-3 compared to dosimetry based on planar images only. Similar results were obtained for the renal dose coefficients. The virtual patients' renal dose coefficients were (0.68 +/- 0.24) Gy/GBq indicating that a population-based method yields an uncertainty of 35%. Conclusion Dosimetry based on the hybrid planar/SPECT method with OSS outperforms dosimetry based on planar images. The high variability in dose coefficients between the virtual patients demonstrates the need for individualized dosimetry.
引用
收藏
页码:5861 / 5866
页数:6
相关论文
共 50 条
  • [21] Single-Time-Point Dosimetry of 177Lu-PSMA-617 Radionuclide Therapy with SPECT/CT
    Burkerr, Brian J.
    RADIOLOGY-IMAGING CANCER, 2023, 5 (02):
  • [22] Investigation of image-based lesion and kidney dosimetry protocols for 177Lu-PSMA-I&T therapy with and without a late SPECT/CT acquisition
    Resch, Sandra
    Fouladgar, Sarah Takayama
    Zacherl, Mathias
    Sheikh, Gabriel T. T.
    Liubchenko, Grigory
    Rumiantcev, Mikhail
    Unterrainer, Lena M. M.
    Wenter, Vera
    Bartenstein, Peter
    Ziegler, Sibylle I. I.
    Ilhan, Harun
    Beyer, Leonie
    Boening, Guido
    Delker, Astrid
    EJNMMI PHYSICS, 2023, 10 (01)
  • [23] A simulation-based method to determine optimal sampling schedules for dosimetry in radioligand therapy
    Rinscheid, Andreas
    Lee, Jeesoo
    Kletting, Peter
    Beer, Ambros J.
    Glatting, Gerhard
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2019, 29 (04): : 314 - 325
  • [24] Investigation of image-based lesion and kidney dosimetry protocols for 177Lu-PSMA-I&T therapy with and without a late SPECT/CT acquisition
    Sandra Resch
    Sarah Takayama Fouladgar
    Mathias Zacherl
    Gabriel T. Sheikh
    Grigory Liubchenko
    Mikhail Rumiantcev
    Lena M. Unterrainer
    Vera Wenter
    Peter Bartenstein
    Sibylle I. Ziegler
    Harun Ilhan
    Leonie Beyer
    Guido Böning
    Astrid Delker
    EJNMMI Physics, 10
  • [25] Safety and dosimetry of 177Lu-PSMA radioligand therapy among patients with a single kidney as compared to patients with both kidneys with or without renal insufficiency before treatment
    Zhang, J.
    Schuchardt, C.
    Kulkarni, H. R.
    Singh, A.
    Baum, R. P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S646 - S647
  • [26] Dosimetry and safety of 177Lu-PSMA radioligand therapy among patients with a single kidney as compared to patients with both kidneys with or without baseline renal insufficiency (RI)
    Zhang, Jingjing
    Schuchardt, Christiane
    Kulkarni, Harshad
    Singh, Aviral
    Baum, Richard
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [27] 3D Whole-Body SPECT images for dosimetry of 177Lu-PSMA treatment using a 360° CZT gamma camera
    Vergnaud, L.
    Giraudet, A.
    Paquet, E.
    Baudier, T.
    Badel, J.
    Sarrut, D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S367 - S367
  • [28] PBPK Pre-trained Deep Learning for Voxel-wise Prediction of Post-therapy Dosimetry for 177Lu-PSMA Therapy
    Xue, Song
    Gafita, Andrei
    Drobnjakovic, Milos
    Afshar-Oromieh, Ali
    Birindelli, Gabriele
    Eiber, Matthias
    Rominger, Axel
    Shi, Kuangyu
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62
  • [29] Voxel-wise Prediction of Post-therapy Dosimetry for 177Lu-PSMA I&T Therapy using Deep Learning
    Xue, Song
    Gafita, Andrei
    Afshar-Oromieh, Ali
    Eiber, Matthias
    Rominger, Axel
    Shi, Kuangyu
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [30] Lu-177-PSMA dosimetry for kidneys and tumors based on SPECT images at two imaging time points
    Chen, Gefei
    Lu, Zhonglin
    Jiang, Han
    Afshar-Oromieh, Ali
    Rominger, Axel
    Shi, Kuangyu
    Mok, Greta S. P.
    FRONTIERS IN MEDICINE, 2023, 10