Study of line-commutated thyristor inverter under voltage dips and novel ride-through solution

被引:0
|
作者
Tian, HY [1 ]
Sng, EKK [1 ]
机构
[1] Nanyang Technol Univ, Sch Elect & Elect Engn, Ctr Adv Power Elect, Singapore 639798, Singapore
关键词
commutationt failure; inverter; voltage dip;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
From industrial experience, it is known that three-phase line commutated thyristor inverters encounter commutation failure during voltage dips. Following commutation failure, both upper & lower thyristors belonging to the same leg of the inverter conduct and a surge current results. This paper gives an analysis of this phenomenon in the event of a single-phase dip. A novel and simple solution for turning off the thyristors in the shorted leg is presented. The proposed scheme detects the short circuit and switches off the thyristors to avoid damage due to excessive current build up. When the three-phase source recovers from the dip, the inverter resumes its normal operation. The proposed scheme has quick response and requires no separate voltage source for control circuits. Experimental verification of the thyristor's turn off mechanism is presented to validate the operation principle.
引用
收藏
页码:1544 / 1549
页数:6
相关论文
共 50 条
  • [31] Low voltage ride-through feature in single phase two stage grid tied PV inverter
    Pirjada, Mahemudmiya
    Nizami, Najma S.
    Dhaneria, Asheesh
    Singh, Ashish
    10TH INTERNATIONAL CONFERENCE ON ELECTRONICS, COMPUTING AND COMMUNICATION TECHNOLOGIES, CONECCT 2024, 2024,
  • [32] Voltage sag assessment method considering low-voltage ride-through of inverter-interfaced distributed generators
    Xiao, Xian-yong
    Song, Gui-shan
    Hu, Wen-Xi
    Song, Xin-yue
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2025, 165
  • [33] A Modified Line-Commutated Inverter for Grid-Connected Photovoltaic Systems with Voltage-Based Maximum Power Point Tracking Method
    Unlu, Murat
    Camur, Sabri
    Beser, Ersoy
    Arifoglu, Birol
    2017 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS (EE), 2017,
  • [34] Robust Control of Two-stage Photovoltaic Inverter for Unbalanced Low Voltage Ride-Through Operation
    Tian, Hao
    Gao, Feng
    Ma, Cong
    He, Guoqing
    Li, Guanghui
    2014 INTERNATIONAL ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2014, : 560 - 565
  • [35] Laguerre polynomial function-based inverter control with low-voltage ride-through capabilities
    Pandey, Amarendra
    Singh, Alka
    INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS, 2023, 51 (02) : 764 - 786
  • [36] Low voltage ride-through control of high power inverter for gird-connection of photovoltaic generation
    Zhou, Jinghua
    Liu, Jindong
    Chen, Yaai
    Li, Jin
    Dianwang Jishu/Power System Technology, 2013, 37 (07): : 1799 - 1807
  • [37] Identification of High and Low Voltage Ride-Through Control Parameters for Electromechanical Transient Modeling of Photovoltaic Inverter
    Jianjie C.
    Bo Z.
    Fang Z.
    Juan H.
    Li Z.
    Distributed Generation and Alternative Energy Journal, 2024, 39 (02): : 195 - 219
  • [38] Low voltage ride-through control strategy of a grid-forming inverter considering power decoupling
    Fu, Yang
    Chen, Yujin
    Ji, Liang
    Li, Shilin
    Yu, Zilin
    Li, Zhenkun
    Mi, Yang
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2024, 52 (15): : 1 - 13
  • [39] NPC Photovoltaic Grid-Connected Inverter with Ride-Through Capability under Grid Faults
    Tafti, Hossein Dehghani
    Maswood, Ali I.
    Lim, Ziyou
    Ooi, Gabriel H. P.
    Raj, Pinkymol Harikrishna
    2015 IEEE 11TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS (PEDS 2015), 2015, : 518 - 523
  • [40] Low Voltage Ride-Through Capability of a Novel Grid Connected Inverter Suitable for Transformer-less solar PV grid interface
    Rajeev, Mini
    Agarwal, Vivek
    2018 8TH IEEE INDIA INTERNATIONAL CONFERENCE ON POWER ELECTRONICS (IICPE), 2018,