Study of line-commutated thyristor inverter under voltage dips and novel ride-through solution

被引:0
|
作者
Tian, HY [1 ]
Sng, EKK [1 ]
机构
[1] Nanyang Technol Univ, Sch Elect & Elect Engn, Ctr Adv Power Elect, Singapore 639798, Singapore
关键词
commutationt failure; inverter; voltage dip;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
From industrial experience, it is known that three-phase line commutated thyristor inverters encounter commutation failure during voltage dips. Following commutation failure, both upper & lower thyristors belonging to the same leg of the inverter conduct and a surge current results. This paper gives an analysis of this phenomenon in the event of a single-phase dip. A novel and simple solution for turning off the thyristors in the shorted leg is presented. The proposed scheme detects the short circuit and switches off the thyristors to avoid damage due to excessive current build up. When the three-phase source recovers from the dip, the inverter resumes its normal operation. The proposed scheme has quick response and requires no separate voltage source for control circuits. Experimental verification of the thyristor's turn off mechanism is presented to validate the operation principle.
引用
收藏
页码:1544 / 1549
页数:6
相关论文
共 50 条
  • [21] Series Voltage Compensation for DFIG Wind Turbine Low-Voltage Ride-Through Solution
    Abdel-Baqi, Omar
    Nasiri, Adel
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (01) : 272 - 280
  • [22] Multi-Functional PV Inverter With Low Voltage Ride-Through and Constant Power Output
    Talha, Muhammad
    Raihan, Siti Rohani Sheikh
    Abd Rahim, Nasrudin
    Akhtar, Muhammad Naveed
    Butt, Osama M.
    Hussain, Muhammad Majid
    IEEE ACCESS, 2022, 10 : 29567 - 29588
  • [24] Research on the Control Technique of Low Voltage Ride-through for Grid-connected Photovoltaic Inverter
    Zhang, Ying
    Cao, Dufeng
    Yang, Zilong
    Wang, Yibo
    Xu, Honghua
    2016 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2016,
  • [25] Low voltage ride-through capability for wind turbines based on current source inverter topologies
    Tenca, Pierluigi
    Rockhill, Andrew A.
    Lipo, Thomas A.
    2007 INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS, VOLS 1-4, 2007, : 1308 - +
  • [26] Voltage sag ride-through for line-connected synchronous motors through flux control
    Pietiläinen, K
    Jansson, M
    Harnefors, L
    PEDS 2003 : FIFTH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS, VOLS 1 AND 2, PROCEEDINGS, 2003, : 1219 - 1223
  • [27] Design and analysis of a voltage ride-through testing solution based on a novel medium-voltage OLTC auto-transformer
    Lopez-Erauskin, Ramon
    Barrenetxea, Manex
    Sagredo-Blanco, Enrique
    Maria Canales, Jose
    Santodomingo Llamas, Fernando
    Duarte, Jose
    2023 25TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, EPE'23 ECCE EUROPE, 2023,
  • [28] Magnetic saturation in transformers used for a self-commutated BTB system with ride-through capability during voltage sags
    Hagiwara, Makoto
    Pham, Phuong Viet
    Akagi, Hirofumi
    2006 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-7, 2006, : 16 - +
  • [29] Fault-Ride through Improvement of DFIG under Symmetrical/Asymmetrical Voltage Dips
    Bekiroglu, Erdal
    Yazar, Muhammed Duran
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2023, 51 (05) : 510 - 523
  • [30] Fault Ride-Through Capability Enhancement by Adapative Voltage Support Control for Inverter Interfaced Distributed Generation
    Zeng, Dehui
    Guo, Jingmei
    Ding, Maosheng
    Geng, Duo
    2015 5TH INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES (DRPT 2015), 2015, : 1924 - 1928