Multi-Isotope Capabilities of a Small-Animal Multi-Pinhole SPECT System

被引:14
|
作者
Lukas, Mathias [1 ]
Kluge, Anne [2 ]
Beindorff, Nicola [3 ]
Brenner, Winfried [1 ,4 ]
机构
[1] Charite Univ Med Berlin, Dept Nucl Med, Augustenburger Pl 1, D-13353 Berlin, Germany
[2] Charite Univ Med Berlin, Dept Radiat Oncol & Radiotherapy, Berlin, Germany
[3] Charite Univ Med Berlin, Berlin Expt Radionuclide Imaging Ctr, Berlin, Germany
[4] Charite Campus Berlin, German Canc Consortium, Berlin, Germany
关键词
multi-isotope; multiplexed multi-pinhole SPECT; performance; quantification; image quality; PERFORMANCE EVALUATION;
D O I
10.2967/jnumed.119.226027
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The quantitative accuracy and image quality of multi-isotope SPECT is affected by various hardware-related perturbations. The present study evaluates the simultaneous acquisition of multiple isotopes using a multiplexed multi-pinhole SPECT system, assesses the extent of different error sources, and proposes experimental procedures for its objective characterization. Methods: Phantom measurements with single-, dual- and triple-isotope combinations of (99)mTc, In-111, I-123, Lu-177, and Tl-201 were performed with the NanoSPECT/CTPI-us to evaluate system energy resolution, count rate performance, sensitivity, collimator penetration, hardware versus object scatter, spectral crosstalk, spatial resolution, spatial registration accuracy, image uniformity, image noise, and image quality. Results: The intrinsic detector properties were suitable for the simultaneous acquisition of up to 3 isotopes with limitations for count rates exceeding 104 kcps and y-energies lower than 75 keV. Spectral crosstalk between isotopes was more likely mediated by hardware than by source scatter and was strongly dependent on the isotope combination. Simultaneous multi-isotope acquisitions slightly degraded spatial resolution and image uniformity for spatially superimposed but not for spatially separated activity distributions while the background noise level was increased for all multi-isotope studies. For particular isotopes, collimator penetration and x-ray fluorescence contributed a significant portion of error. Conclusion: The NanoSPECT/CTPLus enables the simultaneous acquisition of 3 radioisotopes with high quantitative accuracy and only little loss of image quality when the activity ratio is adapted to isotope-specific count rate sensitivities and when the system calibration is performed with phantoms of appropriate size.
引用
收藏
页码:152 / 161
页数:10
相关论文
共 50 条
  • [21] Strategies to Reduce Artifacts and Improve Accuracy in Multiplexed Multi-Pinhole Small Animal SPECT
    DiFilippo, Frank P.
    Patel, Sagar
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3151 - 3154
  • [22] Spectral Multiplexing Multi-Pinhole Collimator Design forHigh Sensitivity Small Animal SPECT
    Wang, Wenying
    Feng, Tao
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2021, 62
  • [23] Performance evaluation of a novel multi-pinhole SPECT system
    Jiang, Nianming
    Liu, Hui
    Xue, Mengle
    Li, Cheng
    Gao, Lilei
    Liu, Fan
    Wu, Jing
    Liu, Yaqiang
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1059
  • [24] Evaluation of multiplexing in multi-pinhole SPECT
    Jorgensen, Aaron K.
    Zeng, Gengsheng L.
    [J]. 2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2213 - 2217
  • [25] A Sensitivity Model for Multi-Pinhole SPECT
    DiFilippo, Frank P.
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1842 - 1847
  • [26] Capabilities of multi-pinhole SPECT with two stationary detectors for in vivo rat imaging
    Jan P. Janssen
    Jan V. Hoffmann
    Takayuki Kanno
    Naoko Nose
    Jan-Peter Grunz
    Masahisa Onoguchi
    Xinyu Chen
    Constantin Lapa
    Andreas K. Buck
    Takahiro Higuchi
    [J]. Scientific Reports, 10
  • [27] Design and Sampling Completeness Evaluation of Scanning Orbits in Multi-pinhole Small Animal SPECT Imaging
    Dai, Tiantian
    Ma, Tianyu
    Wei, Qingyang
    Wang, Shi
    Liu, Hui
    Cui, Junjian
    Huang, Qijie
    Liu, Yaqiang
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2836 - 2839
  • [28] Compact Multi-Pinhole SPECT Imager with Sub-Millimeter Resolution for Small Animal Research
    Lackas, C.
    Hoppin, J. W.
    Schramm, N. U.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S254 - S254
  • [29] Capabilities of multi-pinhole SPECT with two stationary detectors for in vivo rat imaging
    Janssen, Jan P.
    Hoffmann, Jan V.
    Kanno, Takayuki
    Nose, Naoko
    Grunz, Jan-Peter
    Onoguchi, Masahisa
    Chen, Xinyu
    Lapa, Constantin
    Buck, Andreas K.
    Higuchi, Takahiro
    [J]. SCIENTIFIC REPORTS, 2020, 10 (01)
  • [30] Multi-pinhole Dynamic SPECT Imaging: Simulation and System Optimization
    Ma, Dan
    Clough, Anne V.
    Schmidt, Taly Gilat
    [J]. MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622