Design and Sampling Completeness Evaluation of Scanning Orbits in Multi-pinhole Small Animal SPECT Imaging

被引:0
|
作者
Dai, Tiantian [1 ]
Ma, Tianyu [1 ]
Wei, Qingyang [1 ]
Wang, Shi [1 ]
Liu, Hui [1 ]
Cui, Junjian [1 ]
Huang, Qijie [1 ]
Liu, Yaqiang [1 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Key Lab Particle & Radiat Imaging, Minist Educ, Beijing, Peoples R China
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For a multi-pinhole SPECT system, it is important to choose an optimal scanning orbit to fulfill the sampling completeness requirement. In this study, we propose a novel four-degree-of-freedom (4-DOF) orbit which combines a conventional helical scanning path and a superimposed periodic reciprocating 3x3-pioint shift movement in transaxial plane. An Orlov-sphere-based numerical evaluation method was used and a sampling completeness percentage (SCP) index was introduced to access the sampling completeness for the merits of scanning orbits over entire field of view (FOV) in terms of sampling completeness. By comparing distribution of sampling completeness over the FOV of conventional circular orbit, helical orbits, and 4-DOF orbit applied to an experimental small animal SPECT system, it is shown that the novel 4-DOF orbit has better sampling performance than conventional orbits. The evaluation results of different orbits and the mouse whole-body imaging experiment demonstrate that this method is feasible and applicable for guiding the design of scanning orbits and determining the merits of the orbits.
引用
收藏
页码:2836 / 2839
页数:4
相关论文
共 50 条
  • [1] Small animal imaging with multi-pinhole SPECT
    Nuyts, Johan
    Vunckx, Kathleen
    Defrise, Michel
    Vanhove, Christian
    [J]. METHODS, 2009, 48 (02) : 83 - 91
  • [2] Multi-pinhole small animal SPECT
    Schramm, N
    Schurrat, T
    Béhé, M
    Lackas, C
    Hoppin, J
    Ebel, G
    Behr, TM
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S236 - S236
  • [3] Design of rotating multi-pinhole SPECT system for high resolution small animal imaging.
    Ivanovic, M
    Weber, DA
    Loncaric, S
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05): : 174P - 174P
  • [4] Multi-pinhole SPECT for small animal research.
    Schramm, NU
    Engeland, U
    Ebel, G
    Schurrat, T
    Behe, M
    Behr, TM
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05): : 223P - 223P
  • [5] Data completeness in multiplexing multi-pinhole SPECT
    Van Audenhaege, Karen
    Vanhove, Christian
    Vandenberghe, Stefaan
    Van Holen, Roel
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [6] Performance of a multi-pinhole animal SPECT
    Schramm, NU
    Schipper, M
    Schurrat, T
    Béhé, M
    Alfke, H
    Engeland, U
    Ebel, G
    Behr, TA
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2077 - 2079
  • [7] Helical pinhole SPECT for small-animal imaging: A method for addressing sampling completeness
    Metzler, SD
    Greer, KL
    Jaszczak, RJ
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1575 - 1583
  • [8] The Evaluation of Data Completeness and Image Quality in Multiplexing Multi-Pinhole SPECT
    Van Audenhaege, Karen
    Vanhove, Christian
    Vandenberghe, Stefaan
    Van Holen, Roel
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (02) : 474 - 486
  • [9] Design and performance of a multi-pinhole collimation device for small animal imaging with clinical SPECT and SPECT-CT scanners
    DiFilippo, Frank P.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (15): : 4185 - 4201
  • [10] Pinhole PET (pPET): A multi-pinhole collimator insert for small animal SPECT imaging on PET cameras
    Cardi, Christopher A.
    Cao, Zixiong
    Thakur, Mathew L.
    Karp, Joel S.
    Acton, Paul D.
    [J]. 2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1973 - 1976