Shaking table testing of post-tensioned timber frame building with passive energy dissipation systems

被引:38
|
作者
Di Cesare, Antonio [1 ]
Ponzo, Felice Carlo [1 ]
Nigro, Domenico [1 ]
Pampanin, Stefano [2 ]
Smith, Tobias [2 ]
机构
[1] Univ Basilicata, Sch Engn, Potenza, Italy
[2] Univ Canterbury, Dept Civil & Nat Resources Engn, Christchurch, New Zealand
关键词
Shaking table testing; Post-tensioned timber frame; Pres-Lam; Glued laminated timber; Hysteretic dissipative devices; Nonlinear analysis; CROSS-LAMINATED TIMBER;
D O I
10.1007/s10518-017-0115-9
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
A recently developed technology for the construction of multi-storey timber buildings called Pres-Lam uses long lengths of prefabricated laminated timber connected together using pre-stressing steel tendons or bars. A 3-dimensional, 3-storey, 2/3rd scaled Pres-Lam frame building was tested on the shaking table of the structural laboratory of the University of Basilicata. The main objectives of this study were: (1) to confirm the effectiveness of the Pres-Lam technology, originally developed using laminated veneer lumber, for glue laminated (Glulam) timber structures and (2) to validate the current modelling approach in predicting the dynamic response. This paper describes the design, detailing and construction of the experimental model followed by explanation of the testing programme. Two sessions of testing were performed considering different column-base conditions, both with and without the activation of externally mounted dissipative steel angles. The test results are compared with numerical predictions obtained through nonlinear analysis. These numerical models are shown to provide an accurate representation of the dynamic response.
引用
收藏
页码:4475 / 4498
页数:24
相关论文
共 50 条
  • [21] Shaking table tests of seismic-resilient post-tensioned reinforced concrete bridge piers with enhanced bases
    Shen, Yu
    Freddi, Fabio
    Li, Yongxing
    Li, Jianzhong
    [J]. ENGINEERING STRUCTURES, 2024, 305
  • [22] Seismic testing of post-tensioned Pres-Lam core walls using cross laminated timber
    Moroder, Daniel
    Smith, Tobias
    Dunbar, Andrew
    Pampanin, Stefano
    Buchanan, Andrew
    [J]. ENGINEERING STRUCTURES, 2018, 167 : 639 - 654
  • [23] ENERGY DISSIPATION IN POST-TENSIONED SELF-CENTERING PRECAST CONCRETE CONNECTIONS WITH A FRICTION DEVICE
    Koshikawa, Takeaki
    [J]. IMPLEMENTING INNOVATIVE IDEAS IN STRUCTURAL ENGINEERING AND PROJECT MANAGEMENT, 2015, : 31 - 36
  • [24] Moment and energy dissipation capacities of post-tensioned precast concrete connections employing a friction device
    Koshikawa, Takeaki
    [J]. ENGINEERING STRUCTURES, 2017, 138 : 170 - 180
  • [25] Parametrized multi-objective seismic optimization for precast concrete frame with a novel post-tensioned energy dissipation beam-column joint
    He, Zheng
    Gao, Maoxing
    Li, Zhenhui
    Guo, Zhuang
    Ke, Shanjie
    Qi, Zhe
    Tu, Xiang
    Du, Bin
    Lai, Xiao
    [J]. COMPUTERS & STRUCTURES, 2023, 275
  • [26] Passive energy dissipation device for typical steel frame building in Iran
    Tehranizadeh, M
    [J]. ENGINEERING STRUCTURES, 2001, 23 (06) : 643 - 655
  • [27] Experimental seismic response of a resilient 3-storey post-tensioned timber framed building with dissipative braces
    Di Cesare, Antonio
    Ponzo, Felice Carlo
    Lamarucciola, Nicla
    Nigro, Domenico
    [J]. BULLETIN OF EARTHQUAKE ENGINEERING, 2020, 18 (15) : 6825 - 6848
  • [28] Experimental seismic response of a resilient 3-storey post-tensioned timber framed building with dissipative braces
    Antonio Di Cesare
    Felice Carlo Ponzo
    Nicla Lamarucciola
    Domenico Nigro
    [J]. Bulletin of Earthquake Engineering, 2020, 18 : 6825 - 6848
  • [29] Seismic design and shake table tests of a steel post-tensioned self-centering moment frame with a slab accommodating frame expansion
    Chou, Chung-Che
    Chen, Jun-Hen
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2011, 40 (11): : 1241 - 1261
  • [30] DYNAMIC TESTING OF PRECAST, POST-TENSIONED ROCKING WALL SYSTEMS WITH ALTERNATIVE DISSIPATING SOLUTIONS
    Marriott, D.
    Pampanin, S.
    Bull, D.
    Palermo, A.
    [J]. BULLETIN OF THE NEW ZEALAND SOCIETY FOR EARTHQUAKE ENGINEERING, 2008, 41 (02): : 90 - 103