ENERGY DISSIPATION IN POST-TENSIONED SELF-CENTERING PRECAST CONCRETE CONNECTIONS WITH A FRICTION DEVICE

被引:0
|
作者
Koshikawa, Takeaki [1 ]
机构
[1] Hokkaido Univ, Fac Engn, Sapporo, Hokkaido, Japan
关键词
Unbonded; Prestressed concrete; Beam-column connection; Nonlinear section analysis;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an analytical study on the energy dissipation capacity of unbonded post-tensioned self-centering precast concrete beam-column connections that have a friction device only below the beam or on the web. The energy dissipation capacity is quantified using an effective energy dissipation ratio. To quantitatively evaluate the influence of three design parameters on the energy dissipation capacity, nonlinear analyses were carried out using a section-analysis method to predict the relationship between the moment and the relative rotation at the beam-column interface under cyclic loading. The design parameters were the initial post-tensioning force in the unbonded post-tensioning tendon, the friction force, and the location of the friction device. The analysis results show that the effective energy dissipation ratios for connections whose friction devices are in the same location can be related to the ratio of the friction force to the initial post-tensioning force.
引用
收藏
页码:31 / 36
页数:6
相关论文
共 50 条
  • [1] Moment and energy dissipation capacities of post-tensioned precast concrete connections employing a friction device
    Koshikawa, Takeaki
    ENGINEERING STRUCTURES, 2017, 138 : 170 - 180
  • [2] Self-Centering Behavior of Unbonded, Post-Tensioned Precast Concrete Shear Walls
    Erkmen, Bulent
    Schultz, Arturo E.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2009, 13 (07) : 1047 - 1064
  • [3] Experimental study on performance of components of the exterior self-centering post-tensioned precast connections
    Cai, Xiao-Ning
    Meng, Shao-Ping
    Sun, Wei-Wei
    Gongcheng Lixue/Engineering Mechanics, 2014, 31 (03): : 160 - 167
  • [4] Modeling of force-displacement behavior of post-tensioned self-centering concrete connections
    Li, Lu-Xi
    Li, Hong-Nan
    Li, Chao
    Yang, Yeong-Bin
    Zhang, Cai-Yan
    ENGINEERING STRUCTURES, 2019, 198
  • [5] Post-tensioned self-centering moment connections with beam bottom flange energy dissipators
    Chou, Chung-Che
    Lai, Yu-Jen
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (10-11) : 1931 - 1941
  • [6] Numerical analysis for seismic behavior of self-centering post-tensioned precast beam-to-column connections
    Cai X.-N.
    Meng S.-P.
    Gongcheng Lixue/Engineering Mechanics, 2016, 33 (03): : 143 - 151
  • [7] Experimental study on behaviors of beam-column connections for self-centering post-tensioned precast frame
    Cai, Xiaoning
    Meng, Shaoping
    Sun, Weiwei
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2012, 45 (12): : 29 - 37
  • [8] Seismic performance of self-centering connections with steel beams post-tensioned to a reinforced concrete column
    Department of Civil Engineering, National Chiao Tung University, Hsinchu, 30010, Taiwan
    Journal of the CICHE, 2007, 3 (425-437):
  • [9] Seismic performance of RC frames with self-centering precast post-tensioned connections considering the effect of infill walls
    Dai, Kaoshan
    Sun, Tongfei
    Liu, Ye
    Li, Tao
    Xu, Jun
    Bezabeh, Matiyas A.
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2023, 171
  • [10] Probabilistic analysis on time-dependent mechanical behavior of post-tensioned self-centering concrete connections
    Li, Lu-Xi
    Li, Hong-Nan
    Li, Chao
    Dong, Tian-Ze
    ENGINEERING STRUCTURES, 2020, 218