摘要
This paper presents an analytical study on the energy dissipation capacity of unbonded post-tensioned self-centering precast concrete beam-column connections that have a friction device only below the beam or on the web. The energy dissipation capacity is quantified using an effective energy dissipation ratio. To quantitatively evaluate the influence of three design parameters on the energy dissipation capacity, nonlinear analyses were carried out using a section-analysis method to predict the relationship between the moment and the relative rotation at the beam-column interface under cyclic loading. The design parameters were the initial post-tensioning force in the unbonded post-tensioning tendon, the friction force, and the location of the friction device. The analysis results show that the effective energy dissipation ratios for connections whose friction devices are in the same location can be related to the ratio of the friction force to the initial post-tensioning force.
引用
收藏
页码:31 / 36
页数:6
相关论文
共 50 条
  • [41] Discussion on oSelf-Centering Behavior of Unbonded, Post-tensioned Precast Concrete Shear Wallso
    Lu, Xilin
    Wang, Dun
    Cheng, Ming
    JOURNAL OF EARTHQUAKE ENGINEERING, 2010, 14 (04) : 626 - 627
  • [42] Seismic tests of post-tensioned self-centering building frames with column and slab restraints
    Chou C.-C.
    Chen J.-H.
    Frontiers of Architecture and Civil Engineering in China, 2011, 5 (3): : 323 - 334
  • [44] Self-centering modularized link beams with post-tensioned shape memory alloy rods
    Xu, Xian
    Zhang, Yunfeng
    Luo, Yaozhi
    ENGINEERING STRUCTURES, 2016, 112 : 47 - 59
  • [45] Seismic behavior of post-tensioned precast reinforced concrete beam-to-column connections
    Cheng, Chin-Tung
    COMPUTERS AND CONCRETE, 2008, 5 (06): : 525 - 544
  • [46] Experimental and numerical study on low damage self-centering precast concrete energy dissipated frame connections
    Geng, Fangfang
    Li, Yadong
    Wu, Honglei
    Zhang, Yun
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (09): : 170 - 180
  • [47] Seismic Performance of Self-Centering Post-Tensioned Concrete Columns Reinforced with Steel-GFRP Bars and GFRP Spirals
    Tran, Duc Q.
    Pantelides, Chris P.
    JOURNAL OF BRIDGE ENGINEERING, 2024, 29 (08)
  • [48] Seismic design, modelling and assessment of self-centering steel frames using post-tensioned connections with web hourglass shape pins
    Dimopoulos, Athanasios I.
    Karavasilis, Theodore L.
    Vasdravellis, George
    Uy, Brian
    BULLETIN OF EARTHQUAKE ENGINEERING, 2013, 11 (05) : 1797 - 1816
  • [49] Seismic design, modelling and assessment of self-centering steel frames using post-tensioned connections with web hourglass shape pins
    Athanasios I. Dimopoulos
    Theodore L. Karavasilis
    George Vasdravellis
    Brian Uy
    Bulletin of Earthquake Engineering, 2013, 11 : 1797 - 1816
  • [50] Application of precast reinforced concrete fuse units as energy dissipation units in various self-centering precast bridge pier systems
    Moussa, Amr M. A.
    Fahmy, Mohamed F. M.
    Wang, Xin
    Wu, Zhishen
    ADVANCES IN STRUCTURAL ENGINEERING, 2024,