Accuracy of PDFF Estimation by Magnitude-Based and Complex-Based MRI in Children with MR Spectroscopy as a Reference

被引:20
|
作者
Haufe, William M. [1 ]
Wolfson, Tanya [2 ]
Hooker, Catherine A. [1 ]
Hooker, Jonathan C. [1 ]
Covarrubias, Yesenia [1 ]
Schlein, Alex N. [1 ]
Hamilton, Gavin [1 ]
Middleton, Michael S. [1 ]
Angeles, Jorge E. [3 ]
Hernando, Diego [4 ,5 ,6 ]
Reeder, Scott B. [4 ,5 ,6 ,7 ,8 ]
Schwimmer, Jeffrey B. [3 ,9 ]
Sirlin, Claude B. [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, Liver Imaging Grp, San Diego, CA 92103 USA
[2] Univ Calif San Diego, San Diego Supercomp Ctr, Computat & Appl Stat Lab, San Diego, CA 92103 USA
[3] Univ Calif San Diego, Dept Pediat, Div Gastroenterol Hepatol & Nutr, San Diego, CA 92103 USA
[4] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[5] Univ Wisconsin, Dept Med Phys, 1530 Med Sci Ctr, Madison, WI 53706 USA
[6] Univ Wisconsin, Dept Biomed Engn, Madison, WI USA
[7] Univ Wisconsin, Dept Med, Madison, WI USA
[8] Univ Wisconsin, Dept Emergency Med, Madison, WI USA
[9] Rady Childrens Hosp San Diego, Dept Gastroenterol, San Diego, CA USA
基金
美国国家卫生研究院;
关键词
DENSITY FAT-FRACTION; HEPATIC STEATOSIS; LIVER-DISEASE; FLIP-ANGLE; QUANTIFICATION; WATER; SEPARATION; HISTOLOGY; IDEAL; REPRODUCIBILITY;
D O I
10.1002/jmri.25699
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess and compare the accuracy of magnitude-based magnetic resonance imaging (MRI-M) and complexbased MRI (MRI-C) for estimating hepatic proton density fat fraction (PDFF) in children, using MR spectroscopy (MRS) as the reference standard. A secondary aim was to assess the agreement between MRI-M and MRI-C. Materials and Methods: This was a HIPAA-compliant, retrospective analysis of data collected in children enrolled in prospective, Institutional Review Board (IRB)-approved studies between 2012 and 2014. Informed consent was obtained from200 children (ages 8-19 years) who subsequently underwent 3T MR exams that included MRI-M, MRI-C, and T-1-independent, T-2-corrected, single-voxel stimulated echo acquisition mode (STEAM) MRS. Both MRI methods acquired six echoes at low flip angles. T-2(*)-corrected PDFF parametric maps were generated. PDFF values were recorded from regions of interest (ROIs) drawn on the maps in each of the nine Couinaud segments and three ROIs colocalized to the MRS voxel location. Regression analyses assessing agreement with MRS were performed to evaluate the accuracy of each MRI method, and Bland-Altman and intraclass correlation coefficient (ICC) analyses were performed to assess agreement between the MRI methods. Results: MRI-M and MRI-C PDFF were accurate relative to the colocalized MRS reference standard, with regression intercepts of 0.63% and -0.07%, slopes of 0.998 and 0.975, and proportion-of-explained-variance values (R 2) of 0.982 and 0.979, respectively. For individual Couinaud segments and for the whole liver averages, Bland-Altman biases between MRI-M and MRI-C were small (ranging from 0.04 to 1.11%) and ICCs were high (>= 0.978). Conclusion: Both MRI-M and MRI-C accurately estimated hepatic PDFF in children, and high intermethod agreement was observed.
引用
收藏
页码:1641 / 1647
页数:7
相关论文
共 50 条
  • [1] Accuracy of multiecho magnitude-based MRI (M-MRI) for estimation of hepatic proton density fat fraction (PDFF) in children
    Zand, Kevin A.
    Shah, Amol
    Heba, Elhamy
    Wolfson, Tanya
    Hamilton, Gavin
    Lam, Jessica
    Chen, Joshua
    Hooker, Jonathan C.
    Gamst, Anthony C.
    Middleton, Michael S.
    Schwimmer, Jeffrey B.
    Sirlin, Claude B.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (05) : 1223 - 1232
  • [2] Prospective comparison of longitudinal change in hepatic proton density fat fraction (PDFF) estimated by magnitude-based MRI (MRI-M) and complex-based MRI (MRI-C)
    Mamidipalli, Adrija
    Fowler, Kathryn J.
    Hamilton, Gavin
    Wolfson, Tanya
    Covarrubias, Yesenia
    Tran, Calvin
    Fazeli, Soudabeh
    Wiens, Curtis N.
    McMillan, Alan
    Artz, Nathan S.
    Funk, Luke M.
    Campos, Guilherme M.
    Greenberg, Jacob A.
    Gamst, Anthony
    Middleton, Michael S.
    Schwimmer, Jeffrey B.
    Reeder, Scott B.
    Sirlin, Claude B.
    EUROPEAN RADIOLOGY, 2020, 30 (09) : 5120 - 5129
  • [3] Prospective comparison of longitudinal change in hepatic proton density fat fraction (PDFF) estimated by magnitude-based MRI (MRI-M) and complex-based MRI (MRI-C)
    Adrija Mamidipalli
    Kathryn J. Fowler
    Gavin Hamilton
    Tanya Wolfson
    Yesenia Covarrubias
    Calvin Tran
    Soudabeh Fazeli
    Curtis N. Wiens
    Alan McMillan
    Nathan S. Artz
    Luke M. Funk
    Guilherme M. Campos
    Jacob A. Greenberg
    Anthony Gamst
    Michael S. Middleton
    Jeffrey B. Schwimmer
    Scott B. Reeder
    Claude B. Sirlin
    European Radiology, 2020, 30 : 5120 - 5129
  • [4] Intra- and inter-examination repeatability of magnetic resonance spectroscopy, magnitude-based MRI, and complex-based MRI for estimation of hepatic proton density fat fraction in overweight and obese children and adults
    Tyagi, Avishkar
    Yeganeh, Omid
    Levin, Yakir
    Hooker, Jonathan C.
    Hamilton, Gavin C.
    Wolfson, Tanya
    Gamst, Anthony
    Zand, Amir K.
    Heba, Elhamy
    Loomba, Rohit
    Schwimmer, Jeffrey
    Middleton, Michael S.
    Sirlin, Claude B.
    ABDOMINAL IMAGING, 2015, 40 (08): : 3070 - 3077
  • [5] Intra- and inter-examination repeatability of magnetic resonance spectroscopy, magnitude-based MRI, and complex-based MRI for estimation of hepatic proton density fat fraction in overweight and obese children and adults
    Avishkar Tyagi
    Omid Yeganeh
    Yakir Levin
    Jonathan C. Hooker
    Gavin C. Hamilton
    Tanya Wolfson
    Anthony Gamst
    Amir K. Zand
    Elhamy Heba
    Rohit Loomba
    Jeffrey Schwimmer
    Michael S. Middleton
    Claude B. Sirlin
    Abdominal Imaging, 2015, 40 : 3070 - 3077
  • [6] Accuracy and the Effect of Possible Subject-Based Confounders of Magnitude-Based MRI for Estimating Hepatic Proton Density Fat Fraction in Adults, Using MR Spectroscopy as Reference
    Heba, Elhamy R.
    Desai, Ajinkya
    Zand, Kevin A.
    Hamilton, Gavin
    Wolfson, Tanya
    Schlein, Alexandra N.
    Gamst, Anthony
    Loomba, Rohit
    Sirlin, Claude B.
    Middleton, Michael S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (02) : 398 - 406
  • [7] Quantification of MRI-PDFF by complex-based MRI: phantom and rabbit study at 3.0T
    Wang, Xiaomin
    Zhang, Xiaojing
    Ma, Lin
    Li, Shengli
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (09): : 13070 - 13080
  • [8] Combination of Complex-Based and Magnitude-Based Multiecho Water-Fat Separation for Accurate Quantification of Fat-Fraction
    Yu, Huanzhou
    Shimakawa, Ann
    Hines, Catherine D. G.
    McKenzie, Charles A.
    Hamilton, Gavin
    Sirlin, Claude B.
    Brittain, Jean H.
    Reeder, Scott B.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (01) : 199 - 206
  • [9] Magnitude-based pulse width estimation via efficient edge detection
    Ranney, Kenneth
    Tom, Kwok
    Tadas, Dannielle
    Tesny, Neal
    Magill, Andre
    Diehl, William
    JOURNAL OF APPLIED REMOTE SENSING, 2022, 16 (01)
  • [10] Magnitude-Based Angle-of-Arrival Estimation, Localization, and Target Tracking
    Karanam, Chitra R.
    Korany, Belal
    Mostofi, Yasamin
    2018 17TH ACM/IEEE INTERNATIONAL CONFERENCE ON INFORMATION PROCESSING IN SENSOR NETWORKS (IPSN), 2018, : 254 - 265