Accuracy of PDFF Estimation by Magnitude-Based and Complex-Based MRI in Children with MR Spectroscopy as a Reference

被引:20
|
作者
Haufe, William M. [1 ]
Wolfson, Tanya [2 ]
Hooker, Catherine A. [1 ]
Hooker, Jonathan C. [1 ]
Covarrubias, Yesenia [1 ]
Schlein, Alex N. [1 ]
Hamilton, Gavin [1 ]
Middleton, Michael S. [1 ]
Angeles, Jorge E. [3 ]
Hernando, Diego [4 ,5 ,6 ]
Reeder, Scott B. [4 ,5 ,6 ,7 ,8 ]
Schwimmer, Jeffrey B. [3 ,9 ]
Sirlin, Claude B. [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, Liver Imaging Grp, San Diego, CA 92103 USA
[2] Univ Calif San Diego, San Diego Supercomp Ctr, Computat & Appl Stat Lab, San Diego, CA 92103 USA
[3] Univ Calif San Diego, Dept Pediat, Div Gastroenterol Hepatol & Nutr, San Diego, CA 92103 USA
[4] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[5] Univ Wisconsin, Dept Med Phys, 1530 Med Sci Ctr, Madison, WI 53706 USA
[6] Univ Wisconsin, Dept Biomed Engn, Madison, WI USA
[7] Univ Wisconsin, Dept Med, Madison, WI USA
[8] Univ Wisconsin, Dept Emergency Med, Madison, WI USA
[9] Rady Childrens Hosp San Diego, Dept Gastroenterol, San Diego, CA USA
基金
美国国家卫生研究院;
关键词
DENSITY FAT-FRACTION; HEPATIC STEATOSIS; LIVER-DISEASE; FLIP-ANGLE; QUANTIFICATION; WATER; SEPARATION; HISTOLOGY; IDEAL; REPRODUCIBILITY;
D O I
10.1002/jmri.25699
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess and compare the accuracy of magnitude-based magnetic resonance imaging (MRI-M) and complexbased MRI (MRI-C) for estimating hepatic proton density fat fraction (PDFF) in children, using MR spectroscopy (MRS) as the reference standard. A secondary aim was to assess the agreement between MRI-M and MRI-C. Materials and Methods: This was a HIPAA-compliant, retrospective analysis of data collected in children enrolled in prospective, Institutional Review Board (IRB)-approved studies between 2012 and 2014. Informed consent was obtained from200 children (ages 8-19 years) who subsequently underwent 3T MR exams that included MRI-M, MRI-C, and T-1-independent, T-2-corrected, single-voxel stimulated echo acquisition mode (STEAM) MRS. Both MRI methods acquired six echoes at low flip angles. T-2(*)-corrected PDFF parametric maps were generated. PDFF values were recorded from regions of interest (ROIs) drawn on the maps in each of the nine Couinaud segments and three ROIs colocalized to the MRS voxel location. Regression analyses assessing agreement with MRS were performed to evaluate the accuracy of each MRI method, and Bland-Altman and intraclass correlation coefficient (ICC) analyses were performed to assess agreement between the MRI methods. Results: MRI-M and MRI-C PDFF were accurate relative to the colocalized MRS reference standard, with regression intercepts of 0.63% and -0.07%, slopes of 0.998 and 0.975, and proportion-of-explained-variance values (R 2) of 0.982 and 0.979, respectively. For individual Couinaud segments and for the whole liver averages, Bland-Altman biases between MRI-M and MRI-C were small (ranging from 0.04 to 1.11%) and ICCs were high (>= 0.978). Conclusion: Both MRI-M and MRI-C accurately estimated hepatic PDFF in children, and high intermethod agreement was observed.
引用
收藏
页码:1641 / 1647
页数:7
相关论文
共 50 条
  • [21] A joint intensity and edge magnitude-based multilevel thresholding algorithm for the automatic segmentation of pathological MR brain images
    Kaur, Taranjit
    Saini, Barjinder Singh
    Gupta, Savita
    NEURAL COMPUTING & APPLICATIONS, 2018, 30 (04): : 1317 - 1340
  • [22] Estimation of field inhomogeneity map following magnitude-based ambiguity-resolved water-fat separation
    Bagur, Alexandre Triay
    McClymont, Darryl
    Hutton, Chloe
    Borghetto, Andrea
    Gyngell, Michael L.
    Aljabar, Paul
    Robson, Matthew D.
    Brady, Michael
    Bulte, Daniel P.
    MAGNETIC RESONANCE IMAGING, 2023, 97 : 102 - 111
  • [23] Controlled attenuation parameter (CAP): the clinical value based on MRI-PDFF in children with obesity
    Peng, Tianfang
    Yi, Xiaolian
    Lin, Yan
    Dong, Xianhui
    Zhang, Pengwei
    Qiao, Zhihui
    Li, Li
    JOURNAL OF PEDIATRIC ENDOCRINOLOGY & METABOLISM, 2024, 37 (07): : 605 - 612
  • [24] Method of B0 Mapping With Magnitude-Based Correction for Bipolar Two-Point Dixon Cardiac MRI
    Liu, Junmin
    Peters, Dana C.
    Drangova, Maria
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (05) : 1862 - 1869
  • [25] Advancements in manganese complex-based MRI agents: Innovations, design strategies, and future directions
    Roy, Shubham
    Gu, Jingsi
    Xia, Wujiong
    Mi, Chao
    Guo, Bing
    DRUG DISCOVERY TODAY, 2024, 29 (09)
  • [26] A novel heterobimetallic Ru(II)-Gd(III) complex-based magnetoluminescent agent for MR and luminescence imaging
    Shi, Wenbo
    Song, Bo
    Tan, Mingqian
    Ye, Zhiqiang
    Yuan, Jingli
    RSC ADVANCES, 2015, 5 (117) : 96525 - 96531
  • [27] Quick assessment with controlled attenuation parameter for hepatic steatosis in children based on MRI-PDFF as the gold standard
    Jaeseung Shin
    Myung-Joon Kim
    Hyun Joo Shin
    Haesung Yoon
    Seung Kim
    Hong Koh
    Mi-Jung Lee
    BMC Pediatrics, 19
  • [28] Quick assessment with controlled attenuation parameter for hepatic steatosis in children based on MRI-PDFF as the gold standard
    Shin, Jaeseung
    Kim, Myung-Joon
    Shin, Hyun Joo
    Yoon, Haesung
    Kim, Seung
    Koh, Hong
    Lee, Mi-Jung
    BMC PEDIATRICS, 2019, 19 (1)
  • [29] Diagnostic accuracy assessment of molecular prediction model for the risk of NAFLD based on MRI-PDFF diagnosed Chinese Han population
    Zhang, Qing
    Zhu, Yueli
    Yu, Wanjiang
    Xu, Zhipeng
    Zhao, Zhenzhen
    Liu, Shousheng
    Xin, Yongning
    Lv, Kuirong
    BMC GASTROENTEROLOGY, 2021, 21 (01)
  • [30] Diagnostic accuracy assessment of molecular prediction model for the risk of NAFLD based on MRI-PDFF diagnosed Chinese Han population
    Qing Zhang
    Yueli Zhu
    Wanjiang Yu
    Zhipeng Xu
    Zhenzhen Zhao
    Shousheng Liu
    Yongning Xin
    Kuirong Lv
    BMC Gastroenterology, 21