Development of loop-mediated isothermal amplification coupled with nanoparticle-based lateral flow biosensor assay for Mycoplasma pneumoniae detection

被引:36
|
作者
Wang, Yacui [1 ]
Wang, Yi [1 ]
Jiao, Weiwei [1 ]
Li, Jieqiong [1 ]
Quan, Shuting [1 ]
Sun, Lin [1 ]
Wang, Yonghong [1 ]
Qi, Xue [1 ]
Wang, Xingyun [1 ]
Shen, Adong [1 ]
机构
[1] Capital Med Univ, Natl Clin Res Ctr Resp Dis,Natl Key Discipline Pe, Beijing Key Lab Pediat Resp Infect Dis,Minist Edu, Beijing Pediat Res Inst,Beijing Childrens Hosp,Ke, Beijing 100045, Peoples R China
关键词
Mycoplasma pneumoniae; Loop-mediated isothermal amplification; Nanoparticle-based biosensor; Lateral flow biosensor; LAMP-LFB; DIAGNOSIS;
D O I
10.1186/s13568-019-0921-3
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Mycoplasma pneumoniae (MP) is one of the most common pathogens causing respiratory tract infection, especially for community-acquired pneumonia (CAP) in school-age children. There was considerable amount of studies on loop-mediated isothermal amplification (LAMP) assay for MP detection. However, the result interpretation of these developed LAMP assays was sophisticated and subjective. Therefore, we developed and evaluated a LAMP coupled with nanoparticle-based lateral flow biosensor (LFB) assay (LAMP-LFB) for simple, reliable, and objective identification of MP (MP-LAMP-LFB). Six primers specific to P1 gene of MP were designed, and the preferred temperature for this assay was confirmed to be 65 degrees C. The amplification products could be visually interpreted by LFB within 2 min. The MP-LAMP-LFB assay specifically identified DNA templates of MP, and no cross-reactivity with other pathogens was obtained. The limit of the detection for this assay was 600 fg of DNA templates in pure cultures, which was in complete accordance with colorimetric indicator detection and agarose gel electrophoresis analysis. This assay was applied to 209 oropharyngeal swab specimens collected from children with acute respiratory tract infection for clinical evaluation, and compared to real-time PCR detection. Using the LAMP-LFB and real-time PCR assay, the positive rates of MP were 47.8% and 31.6%, respectively. Results suggested that the LAMP-LFB assay displayed high sensitivity compared to real-time PCR method. In summary, LAMP-LFB assay established here was a simple, objective, and sensitive assay for MP detection, which can be widely applied in clinical settings, especially in rural areas.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Loop-mediated isothermal amplification assay for fluorescence analysis and lateral flow detection of male DNA
    Kubo, Seiji
    Niimi, Hideki
    Kitajima, Isao
    ANALYTICAL BIOCHEMISTRY, 2023, 664
  • [32] Rapid detection of Clostridium perfringens in food by loop-mediated isothermal amplification combined with a lateral flow biosensor
    Sridapan, Thanawat
    Tangkawsakul, Wanida
    Janvilisri, Tavan
    Kiatpathomchai, Wansika
    Dangtip, Sirintip
    Ngamwongsatit, Natharin
    Nacapricha, Duangjai
    Ounjai, Puey
    Chankhamhaengdecha, Surang
    PLOS ONE, 2021, 16 (01):
  • [33] Rapid and Visual Detection of SARS-CoV-2 Using Multiplex Reverse Transcription Loop-Mediated Isothermal Amplification Linked With Gold Nanoparticle-Based Lateral Flow Biosensor
    Chen, Xu
    Zhou, Qingxue
    Li, Shijun
    Yan, Hao
    Chang, Bingcheng
    Wang, Yuexia
    Dong, Shilei
    FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2021, 11
  • [34] Loop-mediated isothermal amplification combined with lateral flow biosensor for rapid and sensitive detection of monkeypox virus
    Huang, Xiaolan
    Xiao, Fei
    Jia, Nan
    Sun, Chunrong
    Fu, Jin
    Xu, Zheng
    Cui, Xiaodai
    Huang, Hui
    Qu, Dong
    Zhou, Juan
    Wang, Yi
    FRONTIERS IN PUBLIC HEALTH, 2023, 11
  • [35] Colorimetric Detection of Staphylococcus aureus Based on Direct Loop-Mediated Isothermal Amplification in Combination with Lateral Flow Assay
    Seungjin Lee
    Seung Hyeon Reo
    Seokjoon Kim
    Seokhwan Kim
    Eun Sung Lee
    Byung Seok Cha
    Jiye Shin
    Jinjoo Han
    So Min Ahn
    Han-Seung Shin
    Ki Soo Park
    BioChip Journal, 2024, 18 : 85 - 92
  • [36] Development of Loop-Mediated Isothermal Amplification-Based Lateral Flow Device Method for the Detection of Malaria
    Mallepaddi, Prudhvi Chand
    Lai, Meng-Yee
    Podha, Sudhakar
    Ooi, Choo-Huck
    Liew, Jonathan Wee-Kent
    Polavarapu, Rathnagiri
    Lau, Yee-Ling
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2018, 99 (03): : 704 - 708
  • [37] Colorimetric Detection of Staphylococcus aureus Based on Direct Loop-Mediated Isothermal Amplification in Combination with Lateral Flow Assay
    Lee, Seungjin
    Reo, Seung Hyeon
    Kim, Seokjoon
    Kim, Seokhwan
    Lee, Eun Sung
    Cha, Byung Seok
    Shin, Jiye
    Han, Jinjoo
    Ahn, So Min
    Shin, Han-Seung
    Park, Ki Soo
    BIOCHIP JOURNAL, 2024, 18 (01) : 85 - 92
  • [38] Development of Loop-Mediated Isothermal Amplification Assay for Detection of Entamoeba histolytica
    Liang, Shih-Yu
    Chan, Yun-Hsien
    Hsia, Kan-Tai
    Lee, Jing-Lun
    Kuo, Ming-Chu
    Hwa, Kuo-Yuan
    Chan, Chi-Wen
    Chiang, Ting-Yi
    Chen, Jung-Sheng
    Wu, Fang-Tzy
    Ji, Dar-Der
    JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (06) : 1892 - 1895
  • [39] Development of a loop-mediated isothermal amplification assay for the detection of porcine hokovirus
    Li, Bin
    Sun, Bing
    Du, Lu-ping
    Mao, Ai-hua
    Wen, Li-bin
    Ni, Yan-xiu
    Zhang, Xue-han
    He, Kong-wang
    JOURNAL OF VIROLOGICAL METHODS, 2013, 193 (02) : 415 - 418
  • [40] Development of a loop-mediated isothermal amplification assay for the detection of Mycobacterium bovis
    Zhang, Jun
    Zhang, Gui-Hong
    Yang, Lin
    Huang, Ren
    Zhang, Yu
    Jia, Kun
    Yuan, Wen
    Li, Shou-Jun
    VETERINARY JOURNAL, 2011, 187 (03): : 393 - 396