Evaluation of renal function with 99mTc-MAG3 using semiautomated regions of interest

被引:0
|
作者
Inoue, Y
Yoshikawa, K
Yoshioka, N
Watanabe, T
Saegusa, S
Kaneko, Y
Yokoyama, I
Ohtomo, K
机构
[1] Univ Tokyo, Inst Med Sci, Dept Radiol, Minato Ku, Tokyo 1088639, Japan
[2] Nishi Niigata Cent Natl Hosp, Dept Radiol, Niigata, Japan
[3] Univ Tokyo, Fac Med, Dept Internal Med 2, Tokyo 113, Japan
[4] Univ Tokyo, Fac Med, Dept Radiol, Tokyo 113, Japan
关键词
renal function; Tc-99m-mercaptoacetyltriglycine; region of interest; semiautomated technique; gamma camera;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The need to draw regions of interest (ROIs) manually may reduce the convenience and reliability of estimating renal function from renal scintigraphy. We developed a semiautomated method to define ROIs for renal scintigraphy with Tc-99m-mercaptoacetyltriglycine (MAG3) and evaluated the clinical applicability of the method to the estimation of renal function by camera-based methods. Methods: Dynamic renal scintigraphy with Tc-99m-MAG3 was performed on 21 patients. An operator placed a large rectangular ROI over each kidney, a circular ROI within the liver, and a rectangular ROI between the kidneys. Using these ROIs, semiautomated renal ROIs were determined on the basis of the temporal changes in counts, in addition to the absolute counts, and a subrenal background ROI was automatically assigned for each renal ROI. Background-subtracted renograms were generated using these renal and subrenal ROIs, and renogram parameters were derived from the slope of the renogram and the area under the renogram. Clearance was calculated using the renogram parameters and equations determined previously with manual ROIs and correlated with clearance measured by a single-sample method. The relative function of the right kidney determined by the semiautomated method was compared with that determined by the manual method. Data processing was performed independently by another operator to assess interoperator reproducibility. Results: ROIs defined by the semiautomated method were visually judged to be acceptable for clinical use in all patients with a wide range of renal function. Clearance was successfully predicted with the semiautomated ROIs (r = 0.968 using the slope of the renogram; r = 0.934 using the area under the renogram), and relative function calculated with the semiautomated ROIs was almost identical to that calculated with manual ROIs. There was almost complete concordance in absolute and relative function between the two operators. Conclusion: The semiautomated method can define ROIs for 99mTc-MAG3 renal scintigraphy with limited operator intervention. Camera-based methods using the semiautomated ROIs allow estimation of renal function with high accuracy and little interoperator variability and are suggested to be suitable for clinical use.
引用
收藏
页码:1947 / 1954
页数:8
相关论文
共 50 条
  • [41] Preparation and radiochemical purity control of 99mTc-MAG3
    Rebic, R.
    Beatovic, Slobodanka
    Obradovic, Vladimir
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S529 - S529
  • [42] Vesicocolic Fistula Detected by 99mTc-MAG3 Renogram
    Mannelli, Lorenzo
    Monti, Serena
    Bastawrous, Sarah
    Lomabardo, Ivano
    Behnia, Fatemeh
    CLINICAL NUCLEAR MEDICINE, 2015, 40 (01) : 73 - 75
  • [43] Biokinetcs and Dosimetry of 99mTc-MAG3 scans in infants
    Machado, J. Soares
    Tran-Gia, J.
    Schloegl, S.
    Lassmann, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S398 - S399
  • [44] Development and autoregulation of kidney function in children: a retrospective study using 99mTc-MAG3 renography
    Xinhua Cao
    Xiaoyin Xu
    S. Ted Treves
    Laura A. Drubach
    Neha Kwatra
    Min Zhang
    Frederic H. Fahey
    David A. Diamond
    Stephan D. Voss
    Pediatric Nephrology, 2022, 37 : 2157 - 2166
  • [45] Investigation on labelling procedure and stability of 99mTc-mercaptoacetyltriglicine (99mTc-MAG3)
    Di Franco, M.
    Fantini, L.
    Trevisiol, E.
    Angusti, T.
    Giors, M.
    Micca, A. Botto
    Martino, M.
    Sacco, R.
    Podio, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S330 - S330
  • [46] 99mTc-MAG3 Diuretic Renography: Intra- and Inter-Observer Repeatability in the Assessment of Renal Function
    Sachpekidis, Christos
    Schepers, Robin
    Marti, Monika
    Kopp-Schneider, Annette
    Alberts, Ian
    Keramida, Georgia
    Afshar-Oromieh, Ali
    Rominger, Axel
    DIAGNOSTICS, 2020, 10 (09)
  • [47] Detection of early changes in renal function using 99mTc-MAG3 imaging in a murine model of ischemia-reperfusion injury
    Roberts, John
    Chen, Bo
    Curtis, Lisa M.
    Agarwal, Anupam
    Sanders, Paul W.
    Zinn, Kurt R.
    AMERICAN JOURNAL OF PHYSIOLOGY-RENAL PHYSIOLOGY, 2007, 293 (04) : F1408 - F1412
  • [48] Quality assurance of gamma-camera measurement of 99mTc-MAG3 renal clearance
    Samal, M.
    Ptacnik, V.
    Skibova, D.
    Jiskrova, H.
    Kubinyi, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S187 - S187
  • [49] Quantitative estimation of the renal tubular function with 99mTc-MAG3: comparative software approach using two methods in a pediatric population
    Carapinha, M. J.
    Silva, R.
    Silva, F.
    Figueiredo, S.
    Vieira, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S880 - S880
  • [50] Transport of 99mTc-MAG3 via rat renal organic anion transporter 1
    Shikano, N
    Kanai, Y
    Kawai, K
    Ishikawa, N
    Endou, H
    JOURNAL OF NUCLEAR MEDICINE, 2004, 45 (01) : 80 - 85