Evaluation of renal function with 99mTc-MAG3 using semiautomated regions of interest

被引:0
|
作者
Inoue, Y
Yoshikawa, K
Yoshioka, N
Watanabe, T
Saegusa, S
Kaneko, Y
Yokoyama, I
Ohtomo, K
机构
[1] Univ Tokyo, Inst Med Sci, Dept Radiol, Minato Ku, Tokyo 1088639, Japan
[2] Nishi Niigata Cent Natl Hosp, Dept Radiol, Niigata, Japan
[3] Univ Tokyo, Fac Med, Dept Internal Med 2, Tokyo 113, Japan
[4] Univ Tokyo, Fac Med, Dept Radiol, Tokyo 113, Japan
关键词
renal function; Tc-99m-mercaptoacetyltriglycine; region of interest; semiautomated technique; gamma camera;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The need to draw regions of interest (ROIs) manually may reduce the convenience and reliability of estimating renal function from renal scintigraphy. We developed a semiautomated method to define ROIs for renal scintigraphy with Tc-99m-mercaptoacetyltriglycine (MAG3) and evaluated the clinical applicability of the method to the estimation of renal function by camera-based methods. Methods: Dynamic renal scintigraphy with Tc-99m-MAG3 was performed on 21 patients. An operator placed a large rectangular ROI over each kidney, a circular ROI within the liver, and a rectangular ROI between the kidneys. Using these ROIs, semiautomated renal ROIs were determined on the basis of the temporal changes in counts, in addition to the absolute counts, and a subrenal background ROI was automatically assigned for each renal ROI. Background-subtracted renograms were generated using these renal and subrenal ROIs, and renogram parameters were derived from the slope of the renogram and the area under the renogram. Clearance was calculated using the renogram parameters and equations determined previously with manual ROIs and correlated with clearance measured by a single-sample method. The relative function of the right kidney determined by the semiautomated method was compared with that determined by the manual method. Data processing was performed independently by another operator to assess interoperator reproducibility. Results: ROIs defined by the semiautomated method were visually judged to be acceptable for clinical use in all patients with a wide range of renal function. Clearance was successfully predicted with the semiautomated ROIs (r = 0.968 using the slope of the renogram; r = 0.934 using the area under the renogram), and relative function calculated with the semiautomated ROIs was almost identical to that calculated with manual ROIs. There was almost complete concordance in absolute and relative function between the two operators. Conclusion: The semiautomated method can define ROIs for 99mTc-MAG3 renal scintigraphy with limited operator intervention. Camera-based methods using the semiautomated ROIs allow estimation of renal function with high accuracy and little interoperator variability and are suggested to be suitable for clinical use.
引用
收藏
页码:1947 / 1954
页数:8
相关论文
共 50 条
  • [21] Hematoma versus urinoma: a diagnostic dilemma of 99mTc-MAG3 renal scan in the evaluation of renal transplantation
    Banzo, I.
    Martinez-Rodriguez, I.
    Quirce, R.
    Jimenez-Bonilla, J.
    Portilla-Quattrocciochi, H.
    Carril, J. M.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR, 2011, 30 (04): : 260 - 261
  • [22] 99MTC-MAG3 SPECT/CT DIAGNOSIS OF RENAL TRANSPLANTATION LEAK
    Greenwood, M.
    Pathmaraj, K.
    Lee, S. T.
    Scott, A.
    INTERNAL MEDICINE JOURNAL, 2021, 51 : 18 - 18
  • [23] 99mTc-EC vs. 99mTc-MAG3:: A comparative study of two radiopharmaceuticals for renal function assessment
    Beiki, D.
    Eftekhari, M.
    Fallahi, B.
    Gheisari, F.
    Hojabrossadat, M.
    Fard-Esfahani, A.
    Ansari-Gilani, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S348 - S348
  • [24] Reply to: The reproducibility of measurements of differential renal function in paediatric 99mTc-MAG3 renography: Is this correct?
    Brink, Anita
    Samal, Martin
    Mann, Michael D.
    NUCLEAR MEDICINE COMMUNICATIONS, 2012, 33 (12) : 1311 - 1312
  • [25] Totally automatic definition of renal regions of interest from 99mTc-MAG3 renograms: validation in patients with normal kidneys and in patients with suspected renal obstruction
    Garcia, Ernest V.
    Folks, Russell
    Pak, Samuel
    Taylor, Andrew
    NUCLEAR MEDICINE COMMUNICATIONS, 2010, 31 (05) : 366 - 374
  • [26] Preliminary evaluation of 99mTc-MAEC:: A radiopharmaceutical combining the characteristics of 99mTc-MAG3 and 99mTc-EC.
    Lipowska, M
    Marzilli, LG
    Grant, S
    Taylor, A
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 354P - 354P
  • [27] Evaluation of factors that may contribute to the hepatobiliary excretion of 99mTc-MAG3
    Bento, B.
    Amorim, C.
    Costa, D.
    Santos, P.
    Chin, S.
    Victor, M. R.
    Filipe, M.
    Santos, A. I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S896 - S896
  • [28] Quantitation of renal plasma flow with stage progress of essential hypertension using 99mTc-MAG3
    Mukai, M
    Okuda, Y
    Konishi, S
    Takatsugi, K
    Matsuzaki, K
    Murakami, E
    AMERICAN JOURNAL OF HYPERTENSION, 1999, 12 (04) : 106A - 106A
  • [29] Renal Uptakes of 99mTc-MAG3, 99mTc-DTPA, and 99mTc-DMSA in Rabbits with Unilateral Ureteral Obstruction
    Lee, Won Guk
    Kim, Joong-Hyun
    Kim, Jong Min
    Shim, Kyung Mi
    Kang, Seong Soo
    Chae, Hong In
    Choi, Seok Hwa
    IN VIVO, 2010, 24 (02): : 137 - 139
  • [30] A simple method for determining split renal function from dynamic 99mTc-MAG3 scintigraphic data
    Wesolowski, Michal J.
    Conrad, Gary R.
    Samal, Martin
    Watson, Gage
    Wanasundara, Surajith N.
    Babyn, Paul
    Wesolowski, Carl A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 (03) : 550 - 558