Evaluation of renal function with 99mTc-MAG3 using semiautomated regions of interest

被引:0
|
作者
Inoue, Y
Yoshikawa, K
Yoshioka, N
Watanabe, T
Saegusa, S
Kaneko, Y
Yokoyama, I
Ohtomo, K
机构
[1] Univ Tokyo, Inst Med Sci, Dept Radiol, Minato Ku, Tokyo 1088639, Japan
[2] Nishi Niigata Cent Natl Hosp, Dept Radiol, Niigata, Japan
[3] Univ Tokyo, Fac Med, Dept Internal Med 2, Tokyo 113, Japan
[4] Univ Tokyo, Fac Med, Dept Radiol, Tokyo 113, Japan
关键词
renal function; Tc-99m-mercaptoacetyltriglycine; region of interest; semiautomated technique; gamma camera;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The need to draw regions of interest (ROIs) manually may reduce the convenience and reliability of estimating renal function from renal scintigraphy. We developed a semiautomated method to define ROIs for renal scintigraphy with Tc-99m-mercaptoacetyltriglycine (MAG3) and evaluated the clinical applicability of the method to the estimation of renal function by camera-based methods. Methods: Dynamic renal scintigraphy with Tc-99m-MAG3 was performed on 21 patients. An operator placed a large rectangular ROI over each kidney, a circular ROI within the liver, and a rectangular ROI between the kidneys. Using these ROIs, semiautomated renal ROIs were determined on the basis of the temporal changes in counts, in addition to the absolute counts, and a subrenal background ROI was automatically assigned for each renal ROI. Background-subtracted renograms were generated using these renal and subrenal ROIs, and renogram parameters were derived from the slope of the renogram and the area under the renogram. Clearance was calculated using the renogram parameters and equations determined previously with manual ROIs and correlated with clearance measured by a single-sample method. The relative function of the right kidney determined by the semiautomated method was compared with that determined by the manual method. Data processing was performed independently by another operator to assess interoperator reproducibility. Results: ROIs defined by the semiautomated method were visually judged to be acceptable for clinical use in all patients with a wide range of renal function. Clearance was successfully predicted with the semiautomated ROIs (r = 0.968 using the slope of the renogram; r = 0.934 using the area under the renogram), and relative function calculated with the semiautomated ROIs was almost identical to that calculated with manual ROIs. There was almost complete concordance in absolute and relative function between the two operators. Conclusion: The semiautomated method can define ROIs for 99mTc-MAG3 renal scintigraphy with limited operator intervention. Camera-based methods using the semiautomated ROIs allow estimation of renal function with high accuracy and little interoperator variability and are suggested to be suitable for clinical use.
引用
收藏
页码:1947 / 1954
页数:8
相关论文
共 50 条
  • [1] Assessment of Individual Renal Function Using 99mTc-MAG3 Renography
    Lim, Hyeong-Joon
    Choi, Seok Hwa
    IN VIVO, 2022, 36 (01): : 206 - 211
  • [2] 99MTC-MAG3 RENOGRAPHY IN THE EXPERIMENTAL EVALUATION OF SMALL ANIMAL RENAL FUNCTION
    Kyriazis, Iason
    Kagadis, George
    Loudos, George
    Kallidonis, Panagiotis
    Georgiopoulos, Ioannis
    Liourdi, Despoina
    Apostolopoulos, Dimitris
    Nikiforidis, George
    Liatsikos, Evangelos
    JOURNAL OF ENDOUROLOGY, 2012, 26 : A6 - A7
  • [3] Evaluation of renal function from 99mTc-MAG3 renography without blood sampling
    Inoue, Y
    Ohtake, T
    Yokoyama, I
    Yoshikawa, K
    Asai, S
    Ohtomo, K
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 793 - 798
  • [4] 99mTc-MAG3 Renography of Intrathoracic Renal Ectopia
    ten Broek, Marc R. J.
    te Beek, Erik T.
    Stuurman-Wieringa, Roos E.
    CLINICAL NUCLEAR MEDICINE, 2019, 44 (01) : 78 - 80
  • [5] Pharmacokinetics of 99mTc-MAG3
    Vivier, Pierre-Hugues
    Dacher, Jean-Nicolas
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (04) : W361 - W361
  • [6] Radiopharmacokinetics, renal clearance and dosimetry of 99mTc-MAG3
    de Murphy, CA
    Molina-Trinidad, E
    Meléndez-Alafort, L
    Ferro-Flores, G
    Reyes-Herrera, L
    Sepúlveda-Méndez, J
    Sandoval-Guzmán, B
    Hoyo-Vadillo, C
    ARCHIVES OF MEDICAL RESEARCH, 1999, 30 (01): : 49 - 54
  • [7] Comparison of 99mTc-DMSA, 99mTc-DTPA and 99mTc-MAG3 Renal Scintigraphy in the Calculation of Relative Renal Function
    Demir, Fadime
    Demir, Mustafa
    JOURNAL OF UROLOGICAL SURGERY, 2020, 7 (02): : 130 - 133
  • [8] Differential renal function in pediatrics with pelvi ureteric junctional obstruction using 99mTc-DTPA or 99mTc-MAG3
    El-Maghraby, T. A. F.
    Omar, W. M.
    Abdul-Rahman, N.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S212 - S213
  • [9] The reproducibility of measurements of differential renal function in paediatric 99mTc-MAG3 renography
    Brink, Anita
    Samal, Martin
    Mann, Michael D.
    NUCLEAR MEDICINE COMMUNICATIONS, 2012, 33 (08) : 824 - 831
  • [10] Renal Parenchymal Analysis: 99mTc-MAG3 'v' 99mTc-DMSA
    De Sousa, T.
    Bailey, D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S812 - S812