Simple and rapid LC-MS/MS method for the absolute determination of cetuximab in human serum using an immobilized trypsin

被引:26
|
作者
Shibata, Kaito [1 ]
Naito, Takafumi [1 ]
Okamura, Jun [2 ]
Hosokawa, Seiji [2 ]
Mineta, Hiroyuki [2 ]
Kawakami, Junichi [1 ]
机构
[1] Hamamatsu Univ Sch Med, Dept Hosp Pharm, Higashi Ku, 1-20-1 Handayama, Hamamatsu, Shizuoka 4313192, Japan
[2] Hamamatsu Univ Sch Med, Dept Otorhinolaryngol Head & Neck Surg, Higashi Ku, 1-20-1 Handayama, Hamamatsu, Shizuoka 4313192, Japan
关键词
cetuximab; LC-MS/MS; proteomics; human serum; surrogate peptide; clinical application; SQUAMOUS-CELL CARCINOMA; CHEMOTHERAPY PLUS CETUXIMAB; GROWTH-FACTOR RECEPTOR; 1ST-LINE TREATMENT; JAPANESE PATIENTS; PHASE-II; HEAD; QUANTIFICATION; PHARMACOKINETICS; IMMUNOASSAYS;
D O I
10.1016/j.jpba.2017.08.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Proteomic approaches using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) without an immunopurification technique have not been applied to the determination of serum cetuximab. This study developed a simple and rapid LC-MS/MS method for the absolute determination of cetuximab in human serum and applied it to clinical settings. Surrogate peptides derived from cetuximab digests were selected using a Fourier transform mass spectrometer. Reduced-alkylated serum cetuximab without immunopurification was digested for 20 minutes using immobilized trypsin, and the digestion products were purified by solid-phase extraction. The LC-MS/MS was run in positive ion multiple reaction monitoring mode. This method was applied to the determination of serum samples in head and neck cancer patients treated with cetuximab. The chromatographic run time was 10 minutes and no peaks interfering with surrogate peptides in serum digestion products were observed. The calibration curve of absolute cetuximab in serum was linear over the concentration range of 4-200 mu g/mL. The lower limit of quantification of cetuximab in human serum was 4 mu g/mL. The intra-assay and inter-assay precision and accuracy were less than 13.2% and 88.0-100.7%, respectively. The serum concentration range of cetuximab was 19-140 mu g/mL in patients. The serum cetuximab concentrations in LC-MS/MS were correlated with those in ELISA (r= 0.899, P <0.01) and the mean bias was 1.5% in cancer patients. In conclusion, the present simple and rapid method with acceptable analytical performance can be helpful for evaluating the absolute concentration of serum cetuximab in clinical settings. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:266 / 272
页数:7
相关论文
共 50 条
  • [41] A Simple and Fast Extraction Method for the Determination of Multiclass Antibiotics in Eggs Using LC-MS/MS
    Wang, Kun
    Lin, Kunde
    Huang, Xinwen
    Chen, Meng
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2017, 65 (24) : 5064 - 5073
  • [42] A Simple and Fast Extraction Method for the Determination of Multiclass Antibiotics in Eggs Using LC-MS/MS
    Chen, Meng (mengchen@xmu.edu.cn), 1600, American Chemical Society (65):
  • [43] Determination of tigecycline in human skin using a novel validated LC-MS/MS method
    Ji, Allena Ji
    Saunders, James Patrick
    Amorusi, Peter
    Stein, Gary
    Wadgaonkar, Nandan Dilip
    O'Leary, Kenneth Patrick
    Leal, Mauricio
    Fluhler, Eric Norbert
    BIOANALYSIS, 2010, 2 (01) : 81 - 94
  • [44] A Simple and Rapid LC-MS/MS Method for Quantification of Total Daidzein, Genistein, and Equol in Human Urine
    Saha, Shikha
    Kroon, Paul A.
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2020, 2020
  • [45] A quick and simple method for pyrantel determination in dog plasma by LC-MS/MS
    Bitti, L. Ricci
    Morbidelli, E.
    Rambaldi, J.
    Zaghini, A.
    Barbarossa, A.
    JOURNAL OF VETERINARY PHARMACOLOGY AND THERAPEUTICS, 2018, 41 : 96 - 96
  • [46] A quick and simple method for the determination of ivermectin in dog plasma by LC-MS/MS
    Morbidelli, Eva
    Rambaldi, Julie
    Bitti, Laura Ricci
    Zaghini, Anna
    Barbarossa, Andrea
    METHODSX, 2018, 5 : 1503 - 1507
  • [47] A simple and sensitive LC-MS/MS method for the determination of sotalol in rat plasma
    Feng, Zhiping
    Yu, Siyuan
    Liu, Wei
    Yang, Li
    Liu, Yang
    Zhai, Suodi
    Wang, Fang
    Zhang, Xianhua
    BIOMEDICAL CHROMATOGRAPHY, 2015, 29 (08) : 1167 - 1172
  • [48] Rapid method for the determination of metamizole residues in bovine muscle by LC-MS/MS
    Jedziniak, Piotr
    Pietruk, Konrad
    Sledzinska, Edyta
    Olejnik, Malgorzata
    Szprengier-Juszkiewicz, Teresa
    Zmudzki, Jan
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2013, 30 (06): : 977 - 982
  • [49] Development of a rapid LC-MS/MS method for ribavirin determination in rat brain
    Zironi, Elisa
    Gazzotti, Teresa
    Lugoboni, Barbara
    Barbarossa, Andrea
    Scagliarini, Alessandra
    Pagliuca, Giampiero
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (04) : 889 - 892
  • [50] Determination of Clopidogrel in Human Plasma by a Validated LC-MS/MS Method
    Svinarov, Dobrin A.
    Kasabova, Lilia V.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2012, 138 : A021 - A021