Simple and rapid LC-MS/MS method for the absolute determination of cetuximab in human serum using an immobilized trypsin

被引:26
|
作者
Shibata, Kaito [1 ]
Naito, Takafumi [1 ]
Okamura, Jun [2 ]
Hosokawa, Seiji [2 ]
Mineta, Hiroyuki [2 ]
Kawakami, Junichi [1 ]
机构
[1] Hamamatsu Univ Sch Med, Dept Hosp Pharm, Higashi Ku, 1-20-1 Handayama, Hamamatsu, Shizuoka 4313192, Japan
[2] Hamamatsu Univ Sch Med, Dept Otorhinolaryngol Head & Neck Surg, Higashi Ku, 1-20-1 Handayama, Hamamatsu, Shizuoka 4313192, Japan
关键词
cetuximab; LC-MS/MS; proteomics; human serum; surrogate peptide; clinical application; SQUAMOUS-CELL CARCINOMA; CHEMOTHERAPY PLUS CETUXIMAB; GROWTH-FACTOR RECEPTOR; 1ST-LINE TREATMENT; JAPANESE PATIENTS; PHASE-II; HEAD; QUANTIFICATION; PHARMACOKINETICS; IMMUNOASSAYS;
D O I
10.1016/j.jpba.2017.08.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Proteomic approaches using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) without an immunopurification technique have not been applied to the determination of serum cetuximab. This study developed a simple and rapid LC-MS/MS method for the absolute determination of cetuximab in human serum and applied it to clinical settings. Surrogate peptides derived from cetuximab digests were selected using a Fourier transform mass spectrometer. Reduced-alkylated serum cetuximab without immunopurification was digested for 20 minutes using immobilized trypsin, and the digestion products were purified by solid-phase extraction. The LC-MS/MS was run in positive ion multiple reaction monitoring mode. This method was applied to the determination of serum samples in head and neck cancer patients treated with cetuximab. The chromatographic run time was 10 minutes and no peaks interfering with surrogate peptides in serum digestion products were observed. The calibration curve of absolute cetuximab in serum was linear over the concentration range of 4-200 mu g/mL. The lower limit of quantification of cetuximab in human serum was 4 mu g/mL. The intra-assay and inter-assay precision and accuracy were less than 13.2% and 88.0-100.7%, respectively. The serum concentration range of cetuximab was 19-140 mu g/mL in patients. The serum cetuximab concentrations in LC-MS/MS were correlated with those in ELISA (r= 0.899, P <0.01) and the mean bias was 1.5% in cancer patients. In conclusion, the present simple and rapid method with acceptable analytical performance can be helpful for evaluating the absolute concentration of serum cetuximab in clinical settings. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:266 / 272
页数:7
相关论文
共 50 条
  • [11] Determination of isotretinoin in human serum by LC-MS/MS
    Nam, H. S.
    Yoon, H. J.
    Jung, K. K.
    Kang, I. H.
    Kim, T. S.
    Hong, S. K.
    Kang, T. S.
    TOXICOLOGY LETTERS, 2010, 196 : S39 - S39
  • [12] Simple and rapid LC-MS/MS method for determination of sitagliptin in human plasma and application to bioequivalence study
    Loh, Gabriel Onn Kit
    Wong, Emily Yii Ling
    Tan, Yvonne Tze Fung
    Lee, Yi Lin
    Pang, Lai Hui
    Chin, May Chien
    Damenthi, Nair
    Peh, Kok Khiang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1159
  • [13] Simple and Rapid LC-MS/MS Method for Determination of Perampanel in Human Plasma and Application to Bioequivalence Study
    Gao, Pan
    Zou, Qiao-gen
    CURRENT PHARMACEUTICAL ANALYSIS, 2022, 18 (10) : 919 - 929
  • [14] Determination of vitamin D metabolites in serum using LC-MS and LC-MS/MS
    Bedner, Mary
    Phinney, Karen W.
    Sander, Lane C.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2009, 237 : 301 - 301
  • [15] Validation of rapid and simple LC-MS/MS method for determination of voriconazole in rat plasma
    Araujo, Bx
    Conrado, D. J.
    Palma, E. C.
    Costa, Teresa Dalla
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (04) : 985 - 990
  • [16] A Sensitive and Rapid LC-MS/MS Method for Determination of Berberine in Human Plasma
    Kim, Jae Hee
    Mai, Xuan-Lan
    Kim, Kyu Yeon
    Sim, Min-Seok
    Lee, So-Yeon
    Seo, Hee-Won
    Lee, Gunhee
    Kim, Dae-Jung
    Kim, Kyeong Ho
    MASS SPECTROMETRY LETTERS, 2019, 10 (02) : 56 - 60
  • [17] Development of simple and rapid method for Emicizumab quantification by LC-MS/MS in human plasma
    Josset, Laurie
    Hodin, Sophie
    Delinger, Sandrine
    Marin, Clemence
    Dargaud, Yesim
    Delavenne, Xavier
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 223
  • [18] A simple and rapid LC-MS/MS method for the simultaneous determination of eight antipsychotics in human serum, and its application to therapeutic drug monitoring
    Cao, Yunfeng
    Zhao, Furong
    Chen, Jianxing
    Huang, Ting
    Zeng, Jia
    Wang, Lu
    Sun, Xiaoyu
    Miao, Yanming
    Wang, Shuang
    Chen, Chunwu
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1147
  • [19] Quantitative LC-MS/MS method for nivolumab in human serum using IgG purification and immobilized tryptic digestion
    Abe, Kazuki
    Shibata, Kaito
    Naito, Takafumi
    Karayama, Masato
    Hamada, Etsuko
    Maekawa, Masato
    Yamada, Yasuhide
    Suda, Takafumi
    Kawakami, Junichi
    ANALYTICAL METHODS, 2020, 12 (01) : 54 - 62
  • [20] The Fast and Simple LC-MS/MS Method for Determination of Rifampicin in the Human Blood Plasma
    Baskaran, V
    Sudha, P. D. Chaithanya
    Abishek, T.
    Kumar, Hariesh R.
    Ramesh, G.
    Dang, Raman
    INDIAN JOURNAL OF PHARMACEUTICAL EDUCATION AND RESEARCH, 2024, 58 (02) : s575 - s581