Simple and rapid LC-MS/MS method for the absolute determination of cetuximab in human serum using an immobilized trypsin

被引:26
|
作者
Shibata, Kaito [1 ]
Naito, Takafumi [1 ]
Okamura, Jun [2 ]
Hosokawa, Seiji [2 ]
Mineta, Hiroyuki [2 ]
Kawakami, Junichi [1 ]
机构
[1] Hamamatsu Univ Sch Med, Dept Hosp Pharm, Higashi Ku, 1-20-1 Handayama, Hamamatsu, Shizuoka 4313192, Japan
[2] Hamamatsu Univ Sch Med, Dept Otorhinolaryngol Head & Neck Surg, Higashi Ku, 1-20-1 Handayama, Hamamatsu, Shizuoka 4313192, Japan
关键词
cetuximab; LC-MS/MS; proteomics; human serum; surrogate peptide; clinical application; SQUAMOUS-CELL CARCINOMA; CHEMOTHERAPY PLUS CETUXIMAB; GROWTH-FACTOR RECEPTOR; 1ST-LINE TREATMENT; JAPANESE PATIENTS; PHASE-II; HEAD; QUANTIFICATION; PHARMACOKINETICS; IMMUNOASSAYS;
D O I
10.1016/j.jpba.2017.08.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Proteomic approaches using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) without an immunopurification technique have not been applied to the determination of serum cetuximab. This study developed a simple and rapid LC-MS/MS method for the absolute determination of cetuximab in human serum and applied it to clinical settings. Surrogate peptides derived from cetuximab digests were selected using a Fourier transform mass spectrometer. Reduced-alkylated serum cetuximab without immunopurification was digested for 20 minutes using immobilized trypsin, and the digestion products were purified by solid-phase extraction. The LC-MS/MS was run in positive ion multiple reaction monitoring mode. This method was applied to the determination of serum samples in head and neck cancer patients treated with cetuximab. The chromatographic run time was 10 minutes and no peaks interfering with surrogate peptides in serum digestion products were observed. The calibration curve of absolute cetuximab in serum was linear over the concentration range of 4-200 mu g/mL. The lower limit of quantification of cetuximab in human serum was 4 mu g/mL. The intra-assay and inter-assay precision and accuracy were less than 13.2% and 88.0-100.7%, respectively. The serum concentration range of cetuximab was 19-140 mu g/mL in patients. The serum cetuximab concentrations in LC-MS/MS were correlated with those in ELISA (r= 0.899, P <0.01) and the mean bias was 1.5% in cancer patients. In conclusion, the present simple and rapid method with acceptable analytical performance can be helpful for evaluating the absolute concentration of serum cetuximab in clinical settings. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:266 / 272
页数:7
相关论文
共 50 条
  • [1] LC-MS/MS method for denosumab quantitation in human serum with rapid protein digestion using immobilized trypsin
    Shida, Hiroaki
    Naito, Takafumi
    Shibata, Kaito
    Yamada, Yasuhide
    Kawakami, Junichi
    BIOANALYSIS, 2018, 10 (18) : 1501 - 1510
  • [2] VALIDATED LC-MS/MS METHOD FOR THE ABSOLUTE DETERMINATION OF CETUXIMAB IN HUMAN SERUM AND ITS CLINICAL APPLICATION
    Shibata, K.
    Naito, T.
    Shida, H.
    Kawakami, J.
    CLINICAL PHARMACOLOGY & THERAPEUTICS, 2017, 101 (S1) : S87 - S87
  • [3] Simple and rapid LC-MS/MS method for determination of Piribedil in human plasma
    Alshishani, Anas
    Hasan, Inas
    Ghanayem, Fatima
    Al-khasawneh, Sewar
    Abu Dayah, Alaa
    PHARMACIA, 2022, 69 (03) : 615 - 620
  • [4] RAPID QUANTITATIVE LC-MS/MS METHOD OF TOCILIZUMAB IN HUMAN SERUM USING IMMOBILIZED TRYPTIC DIGESTION.
    Mochizuki, T.
    Shibata, K.
    Naito, T.
    Shimoyama, K.
    Ogawa, N.
    Kawakami, J.
    CLINICAL PHARMACOLOGY & THERAPEUTICS, 2020, 107 : S100 - S100
  • [5] A simple LC-MS/MS method for determination of sitafloxacin in human urine
    Wang, Yuanyuan
    Liu, Yang
    Zhang, Hongwen
    Wang, Yongqing
    Liu, Yun
    Wang, Libin
    Ou, Ning
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 967 : 219 - 224
  • [6] A SIMPLE AND RAPID LC-MS/MS METHOD FOR DETERMINATION OF DEXAMETHASONE IN BOVINE MILK
    Ural, Mehmet Nihat
    Kotan, Arzu
    MACEDONIAN VETERINARY REVIEW, 2020, 43 (01) : 69 - 73
  • [7] Rapid LC-MS/MS method for determination of scopolamine in human plasma
    Alshishani, Anas
    Hasan, Inas
    Ghanayem, Fatima
    Al-khasawneh, Sewar
    Chowdhury, D. F.
    Abu Dayah, Alaa
    PHARMACIA, 2022, 69 (04) : 1035 - 1040
  • [8] A simple and rapid LC-MS/MS method for the determination of amphenicols in Nile tilapia
    Guidi, Leticia Rocha
    Souza Tette, Patricia Amaral
    Gloria, Maria Beatriz A.
    Fernandes, Christian
    FOOD CHEMISTRY, 2018, 262 : 235 - 241
  • [9] LC-MS/MS: a rapid and simple new method for the determination of carbapenem β-lactamases
    Shen, J. L.
    Xu, Y. H.
    She, T. T.
    GENETICS AND MOLECULAR RESEARCH, 2015, 14 (04) : 14457 - 14468
  • [10] Determination of finasteride in human serum by LC-MS/MS
    Nam, Hye-Seon
    Nam, Kyong-Hee
    Jung, Su Hee
    Lee, Jang Woo
    Kang, Jin Yeong
    Hong, Soon Keun
    Kim, Tae Sung
    Kang, Tae Seok
    Yoon, Hae-Jung
    Lee, Kwang Ho
    Rhee, Gyu-Seek
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2011, 24 (05): : 345 - 351