Reproducibility in X-ray reflectometry: results from the first world-wide round-robin experiment

被引:47
|
作者
Colombi, P. [1 ]
Agnihotri, D. K.
Asadchikov, V. E. [2 ]
Bontempi, E. [1 ]
Bowen, D. K.
Chang, C. H.
Depero, L. E. [1 ]
Farnworth, M. [3 ]
Fujimoto, T. [4 ]
Gibaud, A.
Jergel, M. [5 ]
Krumrey, M. [6 ]
Lafford, T. A.
Lamperti, A. [7 ]
Ma, T.
Matyi, R. J. [8 ]
Meduna, M. [9 ]
Milita, S. [10 ]
Sakurai, K. [11 ]
Shabel'nikov, L. [12 ]
Ulyanenkov, A. [13 ]
Van der Lee, A. [14 ]
Wiemer, C. [15 ]
机构
[1] Univ Brescia, Tech Chem Lab, Brescia, Italy
[2] Russian Acad Sci, Xray Reflect Inst Crystallog, Moscow 117901, Russia
[3] Pilkington European Tech Ctr, Lathom, England
[4] AIST, NMII, Surface & Thin Film Standards Sect, Tsukuba, Ibaraki, Japan
[5] Inst Phys SAS, Bratislava, Slovakia
[6] Phys Tech Bundesanstalt, Berlin, Germany
[7] Univ Durham, Dept Phys, Durham DH1 3HP, England
[8] SUNY Albany, Coll Nanoscale Sci & Engn, Albany, NY 12222 USA
[9] Masaryk Univ, Dept Phys Mat Condensee, Brno, Czech Republic
[10] CNR IMM, Bologna, Italy
[11] Natl Inst Mat Sci, Tsukuba, Ibaraki 3050047, Japan
[12] RAS, Inst Microelect Technol, Moscow, Russia
[13] Bruker AXS GmbH, Res Dept, Karlsruhe, Germany
[14] Univ Montpellier 2, Inst Europeen Membranes, UMR 5635, F-34095 Montpellier 5, France
[15] CNR, INFM, Lab MDM, Agrate Brianza, Italy
关键词
D O I
10.1107/S0021889807051904
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
X-ray reflectometry (XRR) is a well established technique to evaluate quantitatively electron density, thickness and roughness of thin layers. In this paper, results of the first world-wide XRR round-robin experiment, involving 20 laboratories, are presented and discussed. The round-robin experiment was performed within the framework of the VAMAS Project 'X-ray reflectivity measurements for evaluation of thin films and multilayers', the aim of which is to produce a 'good practice' manual for XRR. The reproducibility of measurements obtained using different equipment has been investigated. The influence of the fitting of the experimental data was shown to be non-negligible compared with the experimental factors. The dynamic intensity range proves to be an important parameter for obtaining a good quality measurement. A simpler test sample which does not develop a surface oxide layer over time is now the subject of a follow-up study.
引用
收藏
页码:143 / 152
页数:10
相关论文
共 50 条
  • [1] First Total Reflection X-Ray Fluorescence round-robin test of water samples: Preliminary results
    Borgese, Laura
    Bilo, Fabjola
    Tsuji, Kouichi
    Fernández-Ruiz, Ramón
    Margui, Eva
    Streli, Christina
    Pepponi, Giancarlo
    Stosnach, Hagen
    Yamada, Takashi
    Vandenabeele, Peter
    Maina, David M.
    Gatari, Michael
    Shepherd, Keith D.
    Towett, Erick K.
    Bennun, Leonardo
    Custo, Graciela
    Vasquez, Cristina
    Depero, Laura E.
    Spectrochimica Acta - Part B Atomic Spectroscopy, 2014, 101 : 6 - 14
  • [2] First Total Reflection X-Ray Fluorescence round-robin test of water samples: Preliminary results
    Borgese, Laura
    Bilo, Fabjola
    Tsuji, Kouichi
    Fernandez-Ruiz, Ramon
    Margui, Eva
    Streli, Christina
    Pepponi, Giancarlo
    Stosnach, Hagen
    Yamada, Takashi
    Vandenabeele, Peter
    Maina, David M.
    Gatari, Michael
    Shepherd, Keith D.
    Towett, Erick K.
    Bennun, Leonardo
    Custo, Graciela
    Vasquez, Cristina
    Depero, Laura E.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2014, 101 : 6 - 14
  • [3] Possible results of the world-wide round robin test Rockwell hardness
    Polzin, T.
    Schwenk, D.
    HTM - Haerterei-Technische Mitteilungen, 2001, 56 (06): : 395 - 402
  • [4] The first total reflection X-ray fluorescence round-robin test of rat tissue samples: Preliminary results
    Olbrich, Karolina
    Kubala-Kukus, Aldona
    Margui, Eva
    Fernandez-Ruiz, Ramon
    Matusiak, Katarzyna
    Wudarczyk-Mocko, Jolanata
    Wrobel, Pawel
    Setkowicz, Zuzanna
    Chwiej, Joanna
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2023, 205
  • [5] First Preliminary Results from US Round-Robin Tests
    Vayner, Boris V.
    Ferguson, Dale C.
    Hoffmann, Ryan C.
    Wheelock, Adrian T.
    Likar, Justin J.
    Prebola, John L., Jr.
    Crider, Dustin H.
    Schneider, Todd A.
    Vaughn, Jason A.
    Hoang, Bao
    Steele, Kenneth
    Close, Sigrid
    Goel, Ashish
    Crofton, Mark W.
    Young, Jason A.
    Bodeau, J. Michael
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2013, 41 (12) : 3310 - 3322
  • [6] Stress releasing procedure approach for an X-ray mirror holder for round-robin measurements
    Schmidtchen, S.
    Vannoni, M.
    Martin, I. Freijo
    La Civita, D.
    Sinn, H.
    ADVANCES IN METROLOGY FOR X-RAY AND EUV OPTICS VIII, 2019, 11109
  • [7] Round-robin test for X-ray stress analysis standards:: optimization for discrepancy reduction
    Ferreira, C.
    Francois, M.
    Guillen, R.
    JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN, 2008, 43 (01): : 67 - 74
  • [8] The international VAMAS project on X-ray reflectivity measurements for evaluation of thin films and multilayers - Preliminary results from the second round-robin
    Matyi, R. J.
    Depero, L. E.
    Bontempi, E.
    Colombi, P.
    Gibaud, A.
    Jergel, M.
    Krumrey, M.
    Lafford, T. A.
    Lamperti, A.
    Meduna, M.
    Van der Lee, A.
    Wiemer, C.
    THIN SOLID FILMS, 2008, 516 (22) : 7962 - 7966
  • [9] French round-robin test of X-ray stress determination on a shot-peened steel
    Francois, M
    Convert, F
    Branchu, S
    EXPERIMENTAL MECHANICS, 2000, 40 (04) : 361 - 368
  • [10] French round-robin test of X-ray stress determination on a shot-peened steel
    M. François
    F. Convert
    S. Branchu
    Experimental Mechanics, 2000, 40 : 361 - 368