Improvement in breakdown characteristics with multiguard structures in microstrip silicon detectors for CMS

被引:14
|
作者
Bacchetta, N
Bisello, D
Candelori, A
Da Rold, M
Descovich, M
Kaminski, A
Messineo, A
Rizzo, F
Verzellesi, G
机构
[1] Ist Nazl Fis Nucl, Sez Padova, I-35131 Padua, Italy
[2] Univ Padua, Dipartimento Fis, I-35100 Padua, Italy
[3] Univ Pisa, Dipartimento Fis, I-56100 Pisa, Italy
[4] Ist Nazl Fis Nucl, Sez Pisa, Pisa, Italy
[5] Univ Trent, Dipartimento Ingn Mat, Povo, TN USA
关键词
pn junctions; neutron radiation effects; semiconductors; tracking; position sensitive detectors;
D O I
10.1016/S0168-9002(00)01207-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
To obtain full charge collection the CMS silicon detectors should be able to operate at high bias voltage. We observed that multiguard structures enhance the breakdown performance of the devices on several tens of baby detectors designed for CMS. The beneficial effects of the multiguard structures still remains after the strong neutron irradiation performed to simulate the operation at the LHC. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:204 / 206
页数:3
相关论文
共 50 条
  • [21] Results with microstrip detectors produced by STMicroelectronics for the CMS tracker
    Segneri, G
    Borrello, L
    Dell'Orso, R
    Dutta, S
    Fallica, PG
    Mariani, M
    Messineo, A
    Starodumov, A
    Teodorescu, L
    Tonelli, G
    Valvo, G
    Verdini, PG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (03): : 729 - 733
  • [22] Operation and performance of the CMS silicon detectors
    Butz, Erik
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1064
  • [23] Tests of the CMS milestone silicon detectors
    Dell'Orso, R
    Borrello, L
    Bozzi, C
    Della Marina, R
    Messineo, A
    Militaru, O
    Rosi, G
    Tonelli, G
    Verdini, PG
    Wheadon, R
    NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA A-NUCLEI PARTICLES AND FIELDS, 1999, 112 (1-2): : 131 - 136
  • [24] Improvement of Characteristics of Microstrip Antennas Using Unbalanced Structures
    Li, Jian-Ying
    Oo, Zaw Zaw
    Li, Le-Wei
    Kooi, Pang-Shyan
    Leong, Mook-Seng
    IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2002, 1 : 71 - 73
  • [25] Breakdown of coupling dielectrics for Si microstrip detectors
    Candelori, A
    Paccagnella, A
    Saglimbeni, G
    Bisello, D
    NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA A-NUCLEI PARTICLES AND FIELDS, 1999, 112 (1-2): : 87 - 93
  • [26] Operating characteristics of radiation-hardened silicon pixel detectors for the CMS experiment
    Cho, HS
    Chien, CY
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (04) : 1733 - 1736
  • [27] The CMS microstrip silicon tracker system tests
    Marinelli, N
    PROCEEDINGS OF THE EIGHTH WORKSHOP ON ELECTRONICS FOR LHC EXPERIMENTS, 2002, 2002 (03): : 130 - 134
  • [28] Silicon microstrip detectors of ionizing radiation
    Marczewski, J.
    Jaroszewicz, B.
    Kucewicz, W.
    Grabski, P.
    Electron Technology (Warsaw), 1999, 32 (01): : 191 - 192
  • [29] Comprehensive modeling of silicon microstrip detectors
    Passeri, D
    Ciampolini, P
    Baroncini, M
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 118 - 122
  • [30] Silicon microstrip detectors for the ATLAS SCT
    Robinson, D
    Allport, P
    Andricek, L
    Bohm, J
    Buttar, C
    Carter, JR
    Chilingarov, A
    Clark, AG
    Ferrère, D
    Fuster, J
    Garcia, C
    Grigson, C
    Johansen, L
    Lutz, G
    Morone, MC
    Richter, R
    Stugu, B
    Unno, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 485 (1-2): : 84 - 88