Improvement in breakdown characteristics with multiguard structures in microstrip silicon detectors for CMS

被引:14
|
作者
Bacchetta, N
Bisello, D
Candelori, A
Da Rold, M
Descovich, M
Kaminski, A
Messineo, A
Rizzo, F
Verzellesi, G
机构
[1] Ist Nazl Fis Nucl, Sez Padova, I-35131 Padua, Italy
[2] Univ Padua, Dipartimento Fis, I-35100 Padua, Italy
[3] Univ Pisa, Dipartimento Fis, I-56100 Pisa, Italy
[4] Ist Nazl Fis Nucl, Sez Pisa, Pisa, Italy
[5] Univ Trent, Dipartimento Ingn Mat, Povo, TN USA
关键词
pn junctions; neutron radiation effects; semiconductors; tracking; position sensitive detectors;
D O I
10.1016/S0168-9002(00)01207-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
To obtain full charge collection the CMS silicon detectors should be able to operate at high bias voltage. We observed that multiguard structures enhance the breakdown performance of the devices on several tens of baby detectors designed for CMS. The beneficial effects of the multiguard structures still remains after the strong neutron irradiation performed to simulate the operation at the LHC. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:204 / 206
页数:3
相关论文
共 50 条
  • [1] Study of breakdown effects in silicon multiguard structures
    Da Rold, M
    Bacchetta, N
    Bisello, D
    Paccagnella, A
    Dalla Betta, GF
    Verzellesi, G
    Militaru, O
    Wheadon, R
    Fuochi, PG
    Bozzi, C
    Dell'Orso, R
    Messineo, A
    Tonelli, G
    Verdini, PG
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (04) : 1215 - 1223
  • [2] Study of breakdown effects in silicon multiguard structures
    Da Rold, M.
    Bacchetta, N.
    Bisello, D.
    Paccagnella, A.
    Dalla Betta, G.-F.
    Verzellesi, G.
    Militaru, O.
    Wheadon, R.
    Fuochi, P.G.
    Bozzi, C.
    Dell'Orso, R.
    Messineo, A.
    Tonelli, G.
    Verdini, P.G.
    IEEE Transactions on Nuclear Science, 1999, 46 (4 III): : 1215 - 1223
  • [3] The CMS silicon microstrip detectors: research and development
    Bacchetta, N
    Albergo, S
    Azzi, P
    Babucci, E
    Bader, A
    Bagliesi, G
    Bartalini, P
    Basti, A
    Biggeri, U
    Bilei, GM
    Bisello, D
    Boemi, D
    Bosi, F
    Borrello, L
    Bozzi, C
    Breuker, H
    Bruzzi, M
    Candelori, A
    Caner, A
    Castaldi, R
    Castro, A
    Catacchini, E
    Checcucci, B
    Ciampolini, P
    Civinini, C
    Connotte, J
    Creanza, D
    D'Alessandro, R
    Da Rold, M
    de Palma, M
    Dell'Orso, R
    Della Marina, R
    Eklund, C
    Elliott-Peisert, A
    Feld, L
    Fiore, L
    Focardi, E
    French, M
    Freudenreich, K
    Giassi, A
    Giraldo, A
    Glessing, B
    Gu, WH
    Hall, G
    Hammerstrom, R
    Hrubec, J
    Huhtinen, M
    Karimaki, V
    Krammer, M
    Lariccia, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 426 (01): : 16 - 23
  • [4] Silicon microstrip detectors for the CMS experiment at LHC
    Civinini, C
    NUCLEAR PHYSICS B, 1998, : 195 - 200
  • [5] New results on silicon microstrip detectors of CMS tracker
    Demaria, N
    Albergo, S
    Angarano, M
    Azzi, P
    Babucci, E
    Bacchetta, N
    Bader, A
    Bagliesi, G
    Basti, A
    Biggeri, U
    Bilei, GM
    Bisello, D
    Boemi, D
    Bolla, G
    Bosi, F
    Borrello, L
    Bortoletto, D
    Bozzi, C
    Braibant, S
    Breuker, H
    Bruzzi, M
    Buffini, A
    Busoni, S
    Candelori, A
    Caner, A
    Castaldi, R
    Castro, A
    Catacchini, E
    Checcucci, B
    Ciampolini, P
    Civinini, C
    Creanza, D
    D'Alessandro, R
    Da Rold, M
    de Palma, M
    Dell'Orso, R
    Della Marina, R
    Dutta, S
    Eklund, C
    Elliott-Peisert, A
    Favro, G
    Feld, L
    Fiore, L
    Focardi, E
    French, M
    Freudenreich, K
    Fürtjes, A
    Giassi, A
    Giorgi, M
    Giraldo, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 447 (1-2): : 142 - 150
  • [6] Characterization and simulation of CMS-type silicon microstrip detectors
    Bozzi, C
    Bondi, U
    Dell'Orso, R
    Messineo, A
    Rosi, G
    Tonelli, G
    Verdini, PG
    Wheadon, R
    Zhen, X
    NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA A-NUCLEI PARTICLES AND FIELDS, 1999, 112 (1-2): : 67 - 74
  • [7] Results of irradiation quality assurance of CMS silicon microstrip detectors
    Furgeri, Alexander J.
    de Boer, W.
    Hartmann, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 573 (1-2): : 264 - 267
  • [8] Multiguard structures for high-voltage operation of radiation-damaged silicon detectors
    Da Rold, M
    Bacchetta, N
    Bisello, D
    Cavone, M
    Dalla Betta, GF
    De Liso, G
    Dell'Orso, R
    Fuochi, PG
    Lanza, A
    Messineo, A
    Mihul, A
    Militaru, O
    Paccagnella, A
    Tonelli, G
    Verdini, PG
    Verzellesi, G
    Wheadon, R
    NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA A-NUCLEI PARTICLES AND FIELDS, 1999, 112 (1-2): : 13 - 22
  • [9] Noise characteristics in irradiated multiguard structures
    DaRold, M
    Paccagnella, A
    Fardin, P
    Bacchetta, N
    Wheadon, R
    Benetti, P
    Bisello, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3): : 202 - 205
  • [10] Noise characteristics in irradiated multiguard structures
    Da Rold, M.
    Paccagnella, A.
    Fardin, P.
    Bacchetta, N.
    Wheadon, R.
    Benetti, P.
    Bisello, D.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997, 392 (1-3): : 202 - 205