Comparison of field and laboratory methods for monitoring metallic mercury vapor in indoor air

被引:11
|
作者
Singhvi, R
Turpin, R
Kalnicky, DJ
Patel, J
机构
[1] US EPA, Environm Response Team Ctr, Edison, NJ 08837 USA
[2] REAC, Environm Serv, Lockheed Martin Technol Serv Grp, Edison, NJ 08837 USA
关键词
mercury; indoor air; field monitoring; laboratory analysis; statistical evaluation;
D O I
10.1016/S0304-3894(00)00334-4
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Real-time metallic mercury vapor levels of the indoor air were monitored at several mercury spill sites around the US in order to evaluate the effectiveness of site cleanup operations. Mercury readings taken in the field with a Jerome 431 (TM) Mercury Vapor Analyzer were compared with laboratory analysis using a modified National Institute for Occupational Safety and Health (NIOSH) 6009 method. Statistical evaluation showed that the data were highly comparable except at low concentrations, due to the large degree of uncertainty associated with measuring low levels of mercury with the Jerome analyzer. Regression analysis indicated that Jerome measurements of 10 mug/m(3) or greater are comparable for field analysis of mercury vapor in air. Published by Elsevier Science B.V.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [21] Comparison of the effects of e-cigarette vapor and cigarette smoke on indoor air quality
    McAuley, T. R.
    Hopke, P. K.
    Zhao, J.
    Babaian, S.
    INHALATION TOXICOLOGY, 2012, 24 (12) : 850 - 857
  • [22] Comparison of indoor mercury vapor in common areas of residential buildings with outdoor levels in a community where mercury is used for cultural purposes
    Garetano, G
    Gochfed, M
    Stern, AH
    ENVIRONMENTAL HEALTH PERSPECTIVES, 2006, 114 (01) : 59 - 62
  • [23] A LABORATORY EVALUATION OF 2 METHODS FOR MEASURING LOW-LEVELS OF FORMALDEHYDE IN INDOOR AIR
    PETREAS, M
    TWISS, S
    PON, D
    IMADA, M
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1986, 47 (05): : 276 - 280
  • [24] Standardized automated and manual methods to speciate mercury: Field and laboratory studies.
    Landis, MS
    Stevens, RK
    Schaedilich, F
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 223 : U523 - U523
  • [25] MONITORING OF VOLATILE ORGANICS IN AIR WITH FIELD INSTRUMENTATION DEPLOYED IN A MOBILE LABORATORY
    CARNEY, KR
    OVERTON, EB
    WONG, RL
    JACKISCH, MA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 200 : 86 - ENVR
  • [26] Field comparison of manual and semi-automatic methods for the measurement of total gaseous mercury in ambient air and assessment of equivalence
    Brown, Richard J. C.
    Kumar, Yarshini
    Brown, Andrew S.
    Dexter, Matthew A.
    Corns, Warren T.
    JOURNAL OF ENVIRONMENTAL MONITORING, 2012, 14 (02): : 657 - 665
  • [27] PERSONAL MONITORING TECHNIQUE FOR MERCURY-VAPOR IN AIR AND DETERMINATION BY FLAMELESS ATOMIC-ABSORPTION
    RATHJE, AO
    MARCERO, DH
    DATTILO, D
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1974, 35 (09): : 571 - 575
  • [28] FIELD COMPARISON OF 2 PERSONAL FORMALDEHYDE MONITORING METHODS
    PRIHA, E
    AHONEN, I
    ANALYTICAL CHEMISTRY, 1986, 58 (06) : 1195 - 1196
  • [29] Comparison of classical and sensor-based methods for determination of indoor air quality
    Lakestani, S.
    Milli, M.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2025, 22 (02) : 895 - 902
  • [30] Comparison of methods of including stochastic factors into deterministic models of indoor air quality
    Sowa, J
    ENERGY AND BUILDINGS, 1998, 27 (03) : 301 - 308