A reflection-mode fibre-optic sensor for breath carbon dioxide measurement in healthcare

被引:17
|
作者
Liu, LiangLiang [1 ]
Hao, FengHuan [2 ]
Morgan, Stephen P. [1 ]
Correia, Ricardo [1 ]
Norris, Andrew [3 ]
Korposh, Serhiy [1 ]
机构
[1] Univ Nottingham, Fac Engn, Opt & Photon Grp, Nottingham NG7 2RD, England
[2] Hangzhou Appl Acoust Res Inst, Hangzhou 310012, Peoples R China
[3] Nottingham Univ Hosp NHS Trust, Nottingham NG7 2UH, England
基金
英国工程与自然科学研究理事会; 中国国家自然科学基金;
关键词
Optical fibre CO2 sensor; Colorimetric change; pH indicator; Thymol blue; Sol-gel; End-tidal CO2;
D O I
10.1016/j.sbsr.2018.100254
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A reflection-mode carbon dioxide (CO2) fibre optic sensor (FOS) is developed based on the colorimetric change of pH indicator dye thymol blue. The CO2 sensing film comprises thymol blue and tetramethylammonium hydroxide in the form of an ion pair doped in an organically modified silica film. A dip coating process was conducted to coat the sensing film on the tip of optical fibre with a film thickness approximately 2.7 +/- 0.1 mu m. The observed reflection signal at a wavelength of 608 nm exhibits a reversible change for the concentration of CO2 range from 0 to 6% with a response time of 19 s and recovery time of 170 s for 6% of CO2. An optimal concentration of thymol blue in the preparation of coating solution that provides a highest sensitivity was found to be 2.9 mg/ml. Storing the FOS in a pure nitrogen atmosphere provided a stable film with a shelf-life of over 15 days as compared to a gradual degradation in film performance and complete loss of sensitivity after 10 days with storage in ambient air. The FOS response is affected by relative humidity (RH) and a humidity filter was demonstrated to reduce humidity levels in breath from 90% to 40-50% to reduce this effect. The developed FOS was used to measure the end-tidal breath CO2 for testing its applicability in healthcare. The CO2 measurement from breath sample using our FOS shows a good agreement (percentage error similar to 3%) with a commercial CO2 datalogger (K-33 BLG, CO2 Meter, USA). Due to the limitation of response time, at present the FOS is limited to measuring variation of the CO2 from slow breath to breath.
引用
下载
收藏
页数:8
相关论文
共 50 条
  • [41] An intensity-based fibre-optic vibration sensor
    Doyle, C
    Fernando, G
    SMART STRUCTURES AND MATERIALS 1996: SMART SENSING, PROCESSING, AND INSTRUMENTATION, 1996, 2718 : 94 - 102
  • [42] Fibre-optic glucose sensor with a pH optrode as the transducer
    Trettnak, W.
    Leiner, M.J.P.
    Wolfbeis, O.S.
    Biosensors, 1988, 4 (01) : 15 - 26
  • [43] FIBRE-OPTIC GLUCOSE SENSOR WITH A PH OPTRODE AS THE TRANSDUCER
    TRETTNAK, W
    LEINER, MJP
    WOLFBEIS, OS
    BIOSENSORS, 1989, 4 (01) : 15 - 26
  • [44] Fibre-optic load sensor based on polarimetric DBR fibre laser
    Shao, L. -Y.
    Dong, X. Y.
    Tam, H. -Y.
    ELECTRONICS LETTERS, 2008, 44 (02) : 99 - 100
  • [45] Fibre-optic Sagnac interferometer as a sensor of physical quantities
    Jaroszewicz, LR
    Krajewski, Z
    Marc, P
    SECOND EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS: PROCEEDINGS, 2004, 5502 : 390 - 393
  • [46] Wavelength-demultiplexed fibre-optic pressure sensor
    Diankov, G.
    Zafirova, B.
    Angelov, A.
    Kebedjiev, A.
    Journal of Modern Optics, 1993, 40 (01)
  • [47] A fibre-optic sensor for monitoring the polymer cure process
    Chailleux, E
    Salvia, M
    Jaffrezic-Renault, N
    Matejec, V
    Kasik, I
    PHOTONICS, DEVICES,AND SYSTEMS, 2000, 4016 : 136 - 142
  • [48] SPECKLE-BASED FIBRE-OPTIC CURRENT SENSOR
    RAMPRASAD, BS
    BAI, TSR
    OPTICS AND LASER TECHNOLOGY, 1984, 16 (03): : 156 - 158
  • [49] Fibre-optic salinity sensor based on multimode fibre specklegram analysis
    Lin, Wei
    Liu, Bo
    Liu, Haifeng
    Yang, Chengkun
    Zhang, Hao
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2021, 32 (11)
  • [50] Fibre-optic sensor based on surface plasmon resonance
    Homola, J
    Slavik, R
    ELECTRONICS LETTERS, 1996, 32 (05) : 480 - 482