A reflection-mode fibre-optic sensor for breath carbon dioxide measurement in healthcare

被引:17
|
作者
Liu, LiangLiang [1 ]
Hao, FengHuan [2 ]
Morgan, Stephen P. [1 ]
Correia, Ricardo [1 ]
Norris, Andrew [3 ]
Korposh, Serhiy [1 ]
机构
[1] Univ Nottingham, Fac Engn, Opt & Photon Grp, Nottingham NG7 2RD, England
[2] Hangzhou Appl Acoust Res Inst, Hangzhou 310012, Peoples R China
[3] Nottingham Univ Hosp NHS Trust, Nottingham NG7 2UH, England
基金
英国工程与自然科学研究理事会; 中国国家自然科学基金;
关键词
Optical fibre CO2 sensor; Colorimetric change; pH indicator; Thymol blue; Sol-gel; End-tidal CO2;
D O I
10.1016/j.sbsr.2018.100254
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A reflection-mode carbon dioxide (CO2) fibre optic sensor (FOS) is developed based on the colorimetric change of pH indicator dye thymol blue. The CO2 sensing film comprises thymol blue and tetramethylammonium hydroxide in the form of an ion pair doped in an organically modified silica film. A dip coating process was conducted to coat the sensing film on the tip of optical fibre with a film thickness approximately 2.7 +/- 0.1 mu m. The observed reflection signal at a wavelength of 608 nm exhibits a reversible change for the concentration of CO2 range from 0 to 6% with a response time of 19 s and recovery time of 170 s for 6% of CO2. An optimal concentration of thymol blue in the preparation of coating solution that provides a highest sensitivity was found to be 2.9 mg/ml. Storing the FOS in a pure nitrogen atmosphere provided a stable film with a shelf-life of over 15 days as compared to a gradual degradation in film performance and complete loss of sensitivity after 10 days with storage in ambient air. The FOS response is affected by relative humidity (RH) and a humidity filter was demonstrated to reduce humidity levels in breath from 90% to 40-50% to reduce this effect. The developed FOS was used to measure the end-tidal breath CO2 for testing its applicability in healthcare. The CO2 measurement from breath sample using our FOS shows a good agreement (percentage error similar to 3%) with a commercial CO2 datalogger (K-33 BLG, CO2 Meter, USA). Due to the limitation of response time, at present the FOS is limited to measuring variation of the CO2 from slow breath to breath.
引用
下载
收藏
页数:8
相关论文
共 50 条
  • [1] Measurement uncertainty of a fibre-optic displacement sensor
    Nevshupa, Roman
    Conte, Marcello
    van Rijn, Camille
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (03)
  • [2] FIBRE-OPTIC SENSOR PROTOTYPE FOR HUMIDITY MEASUREMENT
    Vieira, Joana C.
    Frias, Clara
    Vieira, Andre C.
    de Oliveira, Rui
    Vasques, Cesar M. A.
    ICEM15: 15TH INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS, 2012,
  • [3] Test Station for Fibre-optic Pressure Sensor of Reflection Type
    Brostilova, Tatiana
    Brostilov, Sergey
    Yurkov, Nikolay
    Bannov, Valeriy
    Grigoriev, Alexey
    2016 13TH INTERNATIONAL CONFERENCE ON MODERN PROBLEMS OF RADIO ENGINEERING, TELECOMMUNICATIONS AND COMPUTER SCIENCE (TCSET), 2016, : 333 - 335
  • [4] Measurement of sensor axis misalignment in fibre-optic accelerometers
    De Freitas, J. M.
    Wooler, J. P. F.
    Nash, P. J.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (07) : 1819 - 1825
  • [5] Fibre-optic sensor technologies for humidity and moisture measurement
    Yeo, T. L.
    Sun, T.
    Grattan, K. T. V.
    SENSORS AND ACTUATORS A-PHYSICAL, 2008, 144 (02) : 280 - 295
  • [6] Respiration measurement using fibre-optic deformation sensor
    Di, Haiting
    Sun, Suping
    Che, Ying
    JOURNAL OF MODERN OPTICS, 2017, 64 (06) : 639 - 645
  • [7] Fibre-optic temperature sensor
    Zhao, Jie
    Fu, Wanshi
    Yadian Yu Shengguang/Piezoelectrics and Acoustooptics, 1994, 16 (02): : 29 - 32
  • [8] Fibre-optic pH sensor
    Hotra, Zenon
    Aksimenteva, Olena
    Hlushyk, Iryna
    Cherpak, Vladyslav
    Stakhira, Pavlo
    TCSET 2006: MODERN PROBLEMS OF RADIO ENGINEERING, TELECOMMUNICATIONS AND COMPUTER SCIENCE, PROCEEDINGS, 2006, : 673 - +
  • [9] Fibre-optic sensor boom
    不详
    PROFESSIONAL ENGINEERING, 1998, 11 (07) : 9 - 9
  • [10] FIBRE-OPTIC MEASUREMENT.
    Anon
    1600, (12):