Impact of motion-associated noise on intrinsic optical signal imaging in humans with optical coherence tomography

被引:4
|
作者
Teussink, Michel M. [1 ]
Cense, Barry [2 ]
van Grinsven, Mark J. J. P. [3 ]
Klevering, B. Jeroen [1 ]
Hoyng, Carel B. [1 ]
Theelen, Thomas [1 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Ophthalmol, NL-6500 HB Nijmegen, Netherlands
[2] Utsunomiya Univ, Ctr Opt Res & Educ, Utsunomiya, Tochigi 3218585, Japan
[3] Radboud Univ Nijmegen, Med Ctr, Diagnost Image Anal Grp, Dept Radiol & Nucl Med, NL-6500 HB Nijmegen, Netherlands
来源
BIOMEDICAL OPTICS EXPRESS | 2015年 / 6卷 / 05期
关键词
HUMAN CONE PHOTORECEPTORS; FIXATIONAL EYE-MOVEMENTS; ADAPTIVE-OPTICS; SCATTERING CHANGES; HIGH-RESOLUTION; MACULAR DEGENERATION; OCT ANGIOGRAPHY; LIGHT RESPONSE; VISUAL PIGMENT; HUMAN RETINA;
D O I
10.1364/BOE.6.001632
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A growing body of evidence suggests that phototransduction can be studied in the human eye in vivo by imaging of fast intrinsic optical signals (IOS). There is consensus concerning the limiting influence of motion-associated imaging noise on the reproducibility of IOS-measurements, especially in those employing spectral-domain optical coherence tomography (SD-OCT). However, no study to date has conducted a comprehensive analysis of this noise in the context of IOS-imaging. In this study, we discuss biophysical correlates of IOS, and we address motion-associated imaging noise by providing correctional post-processing methods. In order to avoid cross-talk of adjacent IOS of opposite signal polarity, cellular resolution and stability of imaging to the level of individual cones is likely needed. The optical Stiles-Crawford effect can be a source of significant IOS-imaging noise if alignment with the peak of the Stiles-Crawford function cannot be maintained. Therefore, complete head stabilization by implementation of a bite-bar may be critical to maintain a constant pupil entry position of the OCT beam. Due to depth-dependent sensitivity fall-off, heartbeat and breathing associated axial movements can cause tissue reflectivity to vary by 29% over time, although known methods can be implemented to null these effects. Substantial variations in reflectivity can be caused by variable illumination due to changes in the beam pupil entry position and angle, which can be reduced by an adaptive algorithm based on slope-fitting of optical attenuation in the choriocapillary lamina. (C) 2015 Optical Society of America
引用
收藏
页码:1632 / 1647
页数:16
相关论文
共 50 条
  • [1] Retinal intrinsic optical signal and optical coherence tomography
    Tumlinson, Alexandre R.
    Hermann, Boris
    Margrain, Tom H.
    Hofer, Bernd
    Povazay, Boris
    Drexler, Wolfgang
    [J]. 1ST CANTERBURY WORKSHOP ON OPTICAL COHERENCE TOMOGRAPHY AND ADAPTIVE OPTICS, 2008, 7139
  • [2] The Impact of Relative Intensity Noise on the Signal in Multiple Reference Optical Coherence Tomography
    Neuhaus, Kai
    Subhash, Hrebesh
    Alexandrov, Sergey
    Dsouza, Roshan
    Hogan, Josh
    Wilson, Carol
    Leahy, Martin
    Slepneva, Svetlana
    Huyet, Guillaume
    [J]. OPTICS AND BIOPHOTONICS IN LOW-RESOURCE SETTINGS II, 2016, 9699
  • [3] Enhancement of intrinsic optical signal recording with split spectrum optical coherence tomography
    Thapa, Damber
    Wang, Benquan
    Lu, Yiming
    Son, Taeyoon
    Yao, Xincheng
    [J]. JOURNAL OF MODERN OPTICS, 2017, 64 (17) : 1800 - 1807
  • [4] Noise and bias in optical coherence tomography intensity signal decorrelation
    Uribe-Patarroyo, Nestor
    Post, Anouk L.
    Ruiz-Lopera, Sebastian
    Faber, Dirk J.
    Bouma, Brett E.
    [J]. OSA CONTINUUM, 2020, 3 (04) : 709 - 741
  • [5] In vivo imaging of intrinsic optical signals in chicken retina with functional optical coherence tomography
    Moayed, Alireza Akhlagh
    Hariri, Sepideh
    Choh, Vivian
    Bizheva, Kostadinka
    [J]. OPTICS LETTERS, 2011, 36 (23) : 4575 - 4577
  • [6] Imaging Motion: A Comprehensive Review of Optical Coherence Tomography Angiography
    Choi, Woo June
    [J]. ADVANCED IMAGING AND BIO TECHNIQUES FOR CONVERGENCE SCIENCE, 2021, 1310 : 343 - 365
  • [7] Optical coherence tomography imaging
    Fujimoto, JG
    [J]. PROCEEDINGS OF THE 12TH WORLD CONGRESS FOR BRONCHOLOGY/12TH WORLD CONGRESS FOR BRONCHOESOPHAGOLOGY, 2002, : 95 - 97
  • [8] Compensation of motion artifacts in intracoronary optical frequency domain imaging and optical coherence tomography
    Ha, Jinyong
    Yoo, Hongki
    Tearney, Guillermo J.
    Bouma, Brett E.
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (06): : 1299 - 1304
  • [9] Compensation of motion artifacts in intracoronary optical frequency domain imaging and optical coherence tomography
    Jinyong Ha
    Hongki Yoo
    Guillermo J. Tearney
    Brett E. Bouma
    [J]. The International Journal of Cardiovascular Imaging, 2012, 28 : 1299 - 1304
  • [10] Motion Signal Detected in Cystic Spaces on Optical Coherence Tomography Angiography
    Michelotti, Monica
    Zhang, Miao
    Hwang, Thomas S.
    Bailey, Steven T.
    Flaxel, Christina J.
    Lauer, Andreas
    Lin, Phoebe
    Campbell, J. Peter
    Wilson, David J.
    Huang, David
    Jia, Yali
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)