Compensation of motion artifacts in intracoronary optical frequency domain imaging and optical coherence tomography

被引:0
|
作者
Jinyong Ha
Hongki Yoo
Guillermo J. Tearney
Brett E. Bouma
机构
[1] Massachusetts General Hospital,Harvard Medical School, Wellman Center for Photomedicine
关键词
Motion artifacts; Image compensation; OCT; OFDI;
D O I
暂无
中图分类号
学科分类号
摘要
Intracoronary optical coherence tomography and optical frequency domain imaging (OFDI) have been utilized for two-dimensional and three-dimensional imaging of vascular microanatomy. Image quality and the spatial accuracy of multidimensional reconstructions, however, can be degraded due to artifacts resulting from relative motion between the intracoronary catheter and the vessel wall. To track the relative motion of a catheter with regard to the vessel, a motion tracking system was incorporated with a standard OFDI system by using wavelength division multiplexing techniques. Motion of the vessel was acquired by a frequency shift of the backscattered light caused by the Doppler effect. A single monochromatic beam was utilized for tracking the relative longitudinal displacements of a catheter-based fiber probe with regard to the vessel. Although two tracking beams are, in general, required to correct for longitudinal motion artifacts, the accurate reconstruction in a longitudinal view was achieved by the Doppler frequency information of a single beam. Our results demonstrate that the single beam based motion tracking scheme is a cost-effective, practical approach to compensating for longitudinal distortions due to cardiac dynamics, thus leading to accurate quantitative analysis of 3D intracoronary OFDI.
引用
收藏
页码:1299 / 1304
页数:5
相关论文
共 50 条
  • [1] Compensation of motion artifacts in intracoronary optical frequency domain imaging and optical coherence tomography
    Ha, Jinyong
    Yoo, Hongki
    Tearney, Guillermo J.
    Bouma, Brett E.
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (06): : 1299 - 1304
  • [2] Measurement and compensation of motion artifacts in spectral domain optical coherence tomography
    Bian, Haiyi
    Gao, Wanrong
    [J]. OPTIK, 2019, 183 : 24 - 29
  • [3] Motion artifacts in optical coherence tomography with frequency-domain ranging
    Yun, SH
    Tearney, GJ
    de Boer, JF
    Bouma, BE
    [J]. OPTICS EXPRESS, 2004, 12 (13): : 2977 - 2998
  • [4] Compensation of motion artifacts in catheter-based optical frequency domain imaging
    Ha, J. Y.
    Shishkov, M.
    Colice, M.
    Oh, W. Y.
    Yoo, H.
    Liu, L.
    Tearney, G. J.
    Bouma, B. E.
    [J]. OPTICS EXPRESS, 2010, 18 (11): : 11418 - 11427
  • [5] Application of Phase Correction for Compensation of Motion Artifacts in Spectral-Domain Optical Coherence Tomography
    Ksenofontov, S. Yu.
    Shilyagin, P. A.
    Terpelov, D. A.
    Novozhilov, A. A.
    Gelikonov, V. M.
    Gelikonov, G. V.
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2020, 63 (01) : 126 - 132
  • [6] Application of Phase Correction for Compensation of Motion Artifacts in Spectral-Domain Optical Coherence Tomography
    S. Yu. Ksenofontov
    P. A. Shilyagin
    D. A. Terpelov
    A. A. Novozhilov
    V. M. Gelikonov
    G. V. Gelikonov
    [J]. Instruments and Experimental Techniques, 2020, 63 : 126 - 132
  • [7] Assessing the efficacy of saline flush in frequency-domain optical coherence tomography for intracoronary imaging
    Kimura, Masahiro
    Takeda, Teruki
    Tsujino, Yasushi
    Matsumoto, Yuichi
    Yamaji, Masayuki
    Sakaguchi, Tomoko
    Maeda, Keiko
    Mabuchi, Hiroshi
    Murakami, Tomoyuki
    [J]. HEART AND VESSELS, 2024, 39 (04) : 310 - 318
  • [8] Assessing the efficacy of saline flush in frequency-domain optical coherence tomography for intracoronary imaging
    Masahiro Kimura
    Teruki Takeda
    Yasushi Tsujino
    Yuichi Matsumoto
    Masayuki Yamaji
    Tomoko Sakaguchi
    Keiko Maeda
    Hiroshi Mabuchi
    Tomoyuki Murakami
    [J]. Heart and Vessels, 2024, 39 : 310 - 318
  • [9] Frequency domain optical coherence tomography techniques in eye imaging
    Wojtkowski, M
    Kowalczyk, A
    Targowski, P
    Gorczynska, I
    [J]. ACTA PHYSICA POLONICA A, 2002, 102 (06) : 739 - 746
  • [10] Suppression of Cardiac Motion Artifacts in Sequential Intracoronary Optical Coherence Images
    Sun Zheng
    Li Mengchan
    [J]. JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2016, 6 (07) : 1787 - 1793