Impact of motion-associated noise on intrinsic optical signal imaging in humans with optical coherence tomography

被引:4
|
作者
Teussink, Michel M. [1 ]
Cense, Barry [2 ]
van Grinsven, Mark J. J. P. [3 ]
Klevering, B. Jeroen [1 ]
Hoyng, Carel B. [1 ]
Theelen, Thomas [1 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Ophthalmol, NL-6500 HB Nijmegen, Netherlands
[2] Utsunomiya Univ, Ctr Opt Res & Educ, Utsunomiya, Tochigi 3218585, Japan
[3] Radboud Univ Nijmegen, Med Ctr, Diagnost Image Anal Grp, Dept Radiol & Nucl Med, NL-6500 HB Nijmegen, Netherlands
来源
BIOMEDICAL OPTICS EXPRESS | 2015年 / 6卷 / 05期
关键词
HUMAN CONE PHOTORECEPTORS; FIXATIONAL EYE-MOVEMENTS; ADAPTIVE-OPTICS; SCATTERING CHANGES; HIGH-RESOLUTION; MACULAR DEGENERATION; OCT ANGIOGRAPHY; LIGHT RESPONSE; VISUAL PIGMENT; HUMAN RETINA;
D O I
10.1364/BOE.6.001632
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A growing body of evidence suggests that phototransduction can be studied in the human eye in vivo by imaging of fast intrinsic optical signals (IOS). There is consensus concerning the limiting influence of motion-associated imaging noise on the reproducibility of IOS-measurements, especially in those employing spectral-domain optical coherence tomography (SD-OCT). However, no study to date has conducted a comprehensive analysis of this noise in the context of IOS-imaging. In this study, we discuss biophysical correlates of IOS, and we address motion-associated imaging noise by providing correctional post-processing methods. In order to avoid cross-talk of adjacent IOS of opposite signal polarity, cellular resolution and stability of imaging to the level of individual cones is likely needed. The optical Stiles-Crawford effect can be a source of significant IOS-imaging noise if alignment with the peak of the Stiles-Crawford function cannot be maintained. Therefore, complete head stabilization by implementation of a bite-bar may be critical to maintain a constant pupil entry position of the OCT beam. Due to depth-dependent sensitivity fall-off, heartbeat and breathing associated axial movements can cause tissue reflectivity to vary by 29% over time, although known methods can be implemented to null these effects. Substantial variations in reflectivity can be caused by variable illumination due to changes in the beam pupil entry position and angle, which can be reduced by an adaptive algorithm based on slope-fitting of optical attenuation in the choriocapillary lamina. (C) 2015 Optical Society of America
引用
收藏
页码:1632 / 1647
页数:16
相关论文
共 50 条
  • [31] Optical Coherence Tomography for Ophthalmology Imaging
    Qin, Jia
    An, Lin
    [J]. OPTICAL IMAGING IN HUMAN DISEASE AND BIOLOGICAL RESEARCH, 2021, 1355 : 197 - 216
  • [32] En Face Optical Coherence Tomography and Optical Coherence Tomography Angiography Imaging of Taxane-Associated Cystoid Macular Edema
    Sridhar, Jayanth
    Shahlaee, Abtin
    Ehmann, David
    Samara, Wasim A.
    Rahimy, Ehsan
    Ho, Allen C.
    Chiang, Allen
    [J]. OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2016, 47 (02): : 176 - 179
  • [33] Functional Optical Coherence Tomography for Intrinsic Signal Optoretinography: Recent Developments and Deployment Challenges
    Kim, Tae-Hoon
    Ma, Guangying
    Son, Taeyoon
    Yao, Xincheng
    [J]. FRONTIERS IN MEDICINE, 2022, 9
  • [34] Update on Optical Coherence Tomography and Optical Coherence Tomography Angiography Imaging in Proliferative Diabetic Retinopathy
    Vaz-Pereira, Sara
    Morais-Sarmento, Tiago
    Engelbert, Michael
    [J]. DIAGNOSTICS, 2021, 11 (10)
  • [35] Speckle noise reduction for optical coherence tomography
    Xiang, SH
    Zhou, L
    Schmitt, JM
    [J]. OPTICAL AND IMAGING TECHNIQUES FOR BIOMONITORING III, PROCEEDINGS OF, 1998, 3196 : 79 - 88
  • [36] Motion Contrast Optical Coherence Tomography Angiography
    Li, Pei
    Zhou, Liping
    Ni, Yang
    Cheng, Yuxuan
    Ding, Zhihua
    Li, Peng
    [J]. 2016 ASIA COMMUNICATIONS AND PHOTONICS CONFERENCE (ACP), 2016,
  • [37] Signal Processing for Spectroscopic Optical Coherence Tomography
    Sebastian, Goebel
    Semih, Agcaer
    Volker, Jaedicke
    Nils, Gerhardt C.
    Hubert, Welp
    Martin, Hofmann
    [J]. BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 : 328 - 328
  • [38] Digital signal processing in optical coherence tomography
    Kulkarni, MD
    Izatt, JA
    [J]. COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS, PROCEEDINGS OF, 1997, 2981 : 2 - 6
  • [39] SIGNAL PROCESSING IN OPTICAL COHERENCE TOMOGRAPHY (OCT)
    Sylwestrzak, Marcin
    Szkulmowski, Maciej
    Szkulmowska, Anna
    Targowski, Piotr
    [J]. SPA 2010: SIGNAL PROCESSING ALGORITHMS, ARCHITECTURES, ARRANGEMENTS, AND APPLICATIONS CONFERENCE PROCEEDINGS, 2010, : 9 - 9
  • [40] Optical coherence elastography: Strain imaging in tissue using optical coherence tomography
    Kennedy, Brendan F.
    Kennedy, Kelsey M.
    Ford, Chris
    McLaughlin, Robert A.
    Bush, Mark B.
    Sampson, David D.
    [J]. 22ND INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, PTS 1-3, 2012, 8421