Image noise due to quantum fluctuations in flat-panel detector based cone-beam CT imaging

被引:4
|
作者
Zhang, Y [1 ]
Ning, R [1 ]
Conover, D [1 ]
Yu, Y [1 ]
机构
[1] Univ Rochester, Dept ECE & Radiol, Rochester, NY 14627 USA
关键词
quantum noise; image noise level; exposure level; detector size; cone-beam CT; flat panel detector;
D O I
10.1117/12.594672
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Quantum noise in cone beam CT (CBCT) imaging was studied to provide quantitative relationships among 3D cone beam image noise level and CT acquisition and reconstruction parameters, which include entrance exposure level, number of projections, and single detector size. It showed that the level of reconstructed image noise, which was caused by quantum noise in projection data, was spatially variant and related to the shape of the scan object, and that the image noise level was inversely proportional to the square root of entrance exposure level per projection, square root of number of projections, and square of detector size. Both computer simulations and real phantom studies were conducted to verify the derived quantitative relationships between image noise level and CT parameters. Shepp-logan head phantom was used in computer simulations to verify the theoretical relation between noise level and detector size, while a real cylindrical oil-uniformed phantom was studied to verify the theoretical relation between noise level and entrance exposure level. The real phantom studies were carried out on a flat panel detector (FPD)-based CBCT system available in our Lab. This work can provide a guide on how to balance various CBCT parameters to achieve satisfactory image quality with desired signal-to-noise ratio, specified spatial resolution, low contrast detectability and minimal x-ray radiation to patients.
引用
收藏
页码:656 / 663
页数:8
相关论文
共 50 条
  • [11] Detector Characterization of a New Flat-Panel Imager: Prospects for Image Quality Improvement in Fluoroscopy and Cone-Beam CT
    Mail, N.
    Moseley, D.
    Siewerdsen, J.
    Jaffray, D.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [12] Flat panel detector-based cone-beam volume CT breast imaging: detector evaluation
    Yu, Y
    Conover, D
    Ning, RL
    [J]. MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 711 - 719
  • [13] Cone-beam CT breast imaging with a flat panel detector - a simulation study
    Chen, LY
    Shaw, CC
    Tu, SJ
    Altunbas, M
    Wang, T
    Lai, CJ
    Liu, XM
    Kappadath, SC
    [J]. MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 943 - 951
  • [14] Ring artifact corrections in flat-panel detector based cone beam CT
    Abu Anas, Emran Mohammad
    Kim, Jaegon
    Lee, Soo Yeol
    Hasan, Md. Kamrul
    [J]. MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [15] Iterative cone-beam CT reconstruction with an off-center flat-panel detector for SPECT/CT
    Hansis, Eberhard
    Sowards-Emmerd, David
    Hines, Horace
    Shao, Lingxiong
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [16] Monte Carlo analysis of relation between patient dose and noise characteristic of flat-panel detector for cone-beam CT
    Nakamori, N
    Yang, YQ
    Yoshida, Y
    Tsunoo, T
    Endo, M
    Sato, K
    [J]. MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 724 - 731
  • [17] Using a flat-panel detector in high resolution cone beam CT for dental imaging
    Baba, R
    Ueda, K
    Okabe, M
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (05) : 285 - 290
  • [18] Image quality of flat panel cone-beam CT
    Rose, G
    Wiegert, J
    Schäfer, D
    Fiedler, K
    Conrads, N
    Timmer, J
    Rasche, V
    Noordhoek, N
    Klotz, E
    Koppe, R
    [J]. MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 677 - 683
  • [19] Model-based iterative reconstruction for flat-panel cone-beam CT with focal spot blur, detector blur, and correlated noise
    Tilley, Steven, II
    Siewerdsen, Jeffrey H.
    Stayman, J. Webster
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (01): : 296 - 319
  • [20] Aging of imaging properties of a CMOS flat-panel detector for dental cone-beam computed tomography
    Kim, D. W.
    Han, J. C.
    Yun, S.
    Kim, H. K.
    [J]. JOURNAL OF INSTRUMENTATION, 2017, 12