Image noise due to quantum fluctuations in flat-panel detector based cone-beam CT imaging

被引:4
|
作者
Zhang, Y [1 ]
Ning, R [1 ]
Conover, D [1 ]
Yu, Y [1 ]
机构
[1] Univ Rochester, Dept ECE & Radiol, Rochester, NY 14627 USA
关键词
quantum noise; image noise level; exposure level; detector size; cone-beam CT; flat panel detector;
D O I
10.1117/12.594672
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Quantum noise in cone beam CT (CBCT) imaging was studied to provide quantitative relationships among 3D cone beam image noise level and CT acquisition and reconstruction parameters, which include entrance exposure level, number of projections, and single detector size. It showed that the level of reconstructed image noise, which was caused by quantum noise in projection data, was spatially variant and related to the shape of the scan object, and that the image noise level was inversely proportional to the square root of entrance exposure level per projection, square root of number of projections, and square of detector size. Both computer simulations and real phantom studies were conducted to verify the derived quantitative relationships between image noise level and CT parameters. Shepp-logan head phantom was used in computer simulations to verify the theoretical relation between noise level and detector size, while a real cylindrical oil-uniformed phantom was studied to verify the theoretical relation between noise level and entrance exposure level. The real phantom studies were carried out on a flat panel detector (FPD)-based CBCT system available in our Lab. This work can provide a guide on how to balance various CBCT parameters to achieve satisfactory image quality with desired signal-to-noise ratio, specified spatial resolution, low contrast detectability and minimal x-ray radiation to patients.
引用
收藏
页码:656 / 663
页数:8
相关论文
共 50 条
  • [1] Noise, sampling, and the number of projections in cone-beam CT with a flat-panel detector
    Zhao, Z.
    Gang, G. J.
    Siewerdsen, J. H.
    [J]. MEDICAL PHYSICS, 2014, 41 (06)
  • [2] Comparison of flat-panel detector with image-intensifier detector for cone-beam CT
    Baba, R
    Konno, Y
    Ueda, M
    Ikeda, S
    [J]. RADIOLOGY, 2000, 217 : 405 - 405
  • [3] Comparison of flat-panel detector and image-intensifier detector for cone-beam CT
    Baba, R
    Konno, Y
    Ueda, K
    Ikeda, S
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (03) : 153 - 158
  • [4] Geometric Calibration of Cone-beam CT with a Flat-panel Detector
    Wu, Dufan
    Li, Liang
    Zhang, Li
    Xing, Yuxiang
    Chen, Zhiqiang
    Xiao, Yongshun
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2952 - 2955
  • [5] Cone-beam CT with a flat-panel detector: From image science to image-guided surgery
    Siewerdsen, Jeffrey H.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S241 - S250
  • [6] Iterative Reconstruction for Circular Cone-Beam CT with an Offset Flat-Panel Detector
    Hansis, Eberhard
    Bredno, Joerg
    Sowards-Emmerd, David
    Shao, Lingxiong
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2228 - 2231
  • [7] Patient-specific scatter correction for flat-panel detector-based cone-beam CT imaging
    Zhao, Wei
    Brunner, Stephen
    Niu, Kai
    Schafer, Sebastian
    Royalty, Kevin
    Chen, Guang-Hong
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (03): : 1339 - 1365
  • [8] Flat-panel cone-beam CT: A novel imaging technology for image-guided procedures
    Siewerdsen, JH
    Jaffray, DA
    Edmundson, GK
    Sanders, WP
    Wong, J
    Martinez, AA
    [J]. MEDICAL IMAGING 2001: VISUALIZATION, DISPLAY, AND IMAGE-GUIDED PROCEDURES, 2001, 4319 : 435 - 444
  • [9] Planar cone-beam computed tomography with a flat-panel detector
    Kim, S. H.
    Kim, D. W.
    Youn, H.
    Kim, D.
    Kam, S.
    Jeon, H.
    Kim, H. K.
    [J]. JOURNAL OF INSTRUMENTATION, 2015, 10
  • [10] Lag correction for flat-panel cone-beam CT in SPECT/CT
    Wang, Jiong
    Hansis, Eberhard
    van de Haar, Peter
    Sowards-Emmerd, David
    Bredno, Joerg
    Shao, Lingxiong
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52