Detection performance of PCR for Legionella pneumophila in environmental samples: a systematic review and meta-analysis

被引:4
|
作者
Yin, Xin [1 ,2 ]
Chen, Ying-Zhou [1 ,3 ]
Ye, Qi-Qing [1 ,2 ]
Liao, Li-Juan [3 ]
Cai, Zhuo-Rui [4 ]
Lin, Min [5 ]
Li, Jia-Na [6 ]
Zhang, Geng-Biao [6 ]
Peng, Xiao-Li [5 ]
Shi, Wen-Fang [7 ]
Guo, Xu-Guang [1 ,7 ,8 ,9 ]
机构
[1] Guangzhou Med Univ, Affiliated Hosp 3, Dept Clin Lab Med, Guangzhou 510150, Peoples R China
[2] Guangzhou Med Univ, Dept Pediat, Pediat Sch, Guangzhou 510182, Peoples R China
[3] Guangzhou Med Univ, Dept Clin Med, Sch Clin 1, Guangzhou 511436, Peoples R China
[4] Guangzhou Med Univ, Dept Prevent Med, Sch Publ Hlth, Guangzhou 511436, Peoples R China
[5] Guangzhou Med Univ, Clin Sch Tradit Chinese & Western Med, Dept Tradit Chinese & Western Med Clin Med, Guangzhou 511436, Peoples R China
[6] Guangzhou Med Univ, Sch Clin 2, Dept Med Imaging, Guangzhou 511436, Peoples R China
[7] Guangzhou Med Univ, Sch Clin 3, Dept Clin Med, Guangzhou 511436, Peoples R China
[8] Guangzhou Med Univ, Affiliated Hosp 3, Key Lab Major Obstetr Dis Guangdong Prov, Guangzhou 510150, Peoples R China
[9] Guangzhou Med Univ, Affiliated Hosp 3, Guangdong Higher Educ Inst, Key Lab Reprod & Genet, Guangzhou 510150, Peoples R China
关键词
Legionella pneumophila; L; pneumophila; PCR; Diagnosis; REAL-TIME PCR; POLYMERASE-CHAIN-REACTION; WATER SAMPLES; QUANTITATIVE PCR; CULTURE; SPP; QUANTIFICATION; QPCR;
D O I
10.1186/s12941-022-00503-9
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background Legionellosis remains a public health problem. The most common diagnostic method to detect Legionella pneumophila (L. pneumophila) is culture. Polymerase chain reaction (PCR) is a fast and accurate method for this detection in environmental samples. Methods Four databases were searched for studies that evaluated the detection efficiency of PCR in L. pneumophila. The quality evaluation was conducted using Review Manager 5.3. We used Meta-DiSc 1.4 software and the Stata 15.0 software to create forest plots, a meta-regression, a bivariate boxplot and a Deeks' funnel plot. Results A total of 18 four-fold tables from 16 studies were analysed. The overall pooled sensitivity and specificity of PCR was 94% and 72%, respectively. The positive likelihood ratio (RLR) and negative likelihood ratio (NLR) was 2.73 and 0.12, respectively. The result of the diagnostic odds ratio (DOR) was 22.85 and the area under the curve (AUC) was 0.7884. Conclusion Establishing a laboratory diagnostic tool for L. pneumophila detection is important for epidemiological studies. In this work, PCR demonstrated a promising diagnostic accuracy for L. pneumophila.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Diagnostic performance of PET for detection of cardiac amyloidosis: A systematic review and meta-analysis
    Kim, Sang Hyun
    Kim, Yun Seong
    Kim, Seong-Jang
    JOURNAL OF CARDIOLOGY, 2020, 76 (06) : 618 - 625
  • [42] Performance of deep learning in the detection of intracranial aneurysm: systematic review and meta-analysis
    Gu, Feng
    Wu, Xiaoxiao
    Wu, Wenxue
    Wang, Zilan
    Yang, Xingyu
    Chen, Zhouqing
    Wang, Zhong
    Chen, Gang
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 155
  • [43] SPR based immunosensor for detection of Legionella pneumophila in water samples
    Enrico, De Lorenzis
    Manera, Maria G.
    Montagna, Giovanni
    Cimaglia, Fabio
    Chiesa, Maurizio
    Poltronieri, Palmiro
    Santino, Angelo
    Rella, Roberto
    OPTICS COMMUNICATIONS, 2013, 294 : 420 - 426
  • [44] Efficacy of PCR Analysis of Mip, Doth and Gspd Genes with Culture in Detection of Legionella pneumophila
    Bagheri, Hamid
    Khaledi, Azad
    Ghanizadeh, Ghader
    Esmaeili, Davoud
    IRANIAN JOURNAL OF PUBLIC HEALTH, 2021, 50 (05) : 1079 - 1081
  • [45] Design of an optical nanobiosensor for detection of Legionella pneumophila in water samples
    Karimiravesh, Raheleh
    Mobarez, Ashraf Mohabati
    Behmanesh, Mehrdad
    Nikkhah, Maryam
    Abadi, Amin Talebi Bezmin
    Esmaeilli, Saber
    IRANIAN JOURNAL OF MICROBIOLOGY, 2022, 14 (06) : 802 - 812
  • [46] Evaluation of Legionella V-TesT for the detection of Legionella pneumophila antigen in urine samples
    J. P. Bruin
    M. F. Peeters
    E. P. F. IJzerman
    B. M. W. Diederen
    European Journal of Clinical Microbiology & Infectious Diseases, 2010, 29 : 899 - 900
  • [47] Simultaneous detection of Legionella species and Legionella pneumophila by duplex PCR (dPCR) assay in cooling tower water samples from Jakarta, Indonesia
    Yasmon, Andi
    Yusmaniar
    Karuniawati, Anis
    Bela, Budiman
    MEDICAL JOURNAL OF INDONESIA, 2010, 19 (04) : 223 - 227
  • [48] Evaluation of Legionella V-TesT for the detection of Legionella pneumophila antigen in urine samples
    Bruin, J. P.
    Peeters, M. F.
    IJzerman, E. P. F.
    Diederen, B. M. W.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2010, 29 (07) : 899 - 900
  • [49] Comparison of clinical and environmental samples of Legionella pneumophila at the nucleotide sequence level
    Coscolla, Mireia
    Gonzalez-Candelas, Fernando
    INFECTION GENETICS AND EVOLUTION, 2009, 9 (05) : 882 - 888
  • [50] Tactile Detection in Fibromyalgia: A Systematic Review and a Meta-Analysis
    Augiere, Tania
    Desjardins, Audrey
    Paquette Raynard, Emmanuelle
    Brun, Clementine
    Pinard, Anne Marie
    Simoneau, Martin
    Mercier, Catherine
    FRONTIERS IN PAIN RESEARCH, 2021, 2