Diagnostic performance of PET for detection of cardiac amyloidosis: A systematic review and meta-analysis

被引:8
|
作者
Kim, Sang Hyun [1 ]
Kim, Yun Seong [2 ,3 ]
Kim, Seong-Jang [3 ,4 ,5 ]
机构
[1] Dongnam Inst Radiol & Med Sci, Dept Internal Med, Busan, South Korea
[2] Pusan Natl Univ, Dept Internal Med, Yangsan Hosp, Yangsan, South Korea
[3] Pusan Natl Univ, BioMed Res Inst Convergence Biomed Sci & Technol, Yangsan Hosp, Yangsan 50612, South Korea
[4] Pusan Natl Univ, Coll Med, Dept Nucl Med, Yangsan, South Korea
[5] Pusan Natl Univ, Dept Nucl Med, Yangsan Hosp, Yangsan, South Korea
关键词
Amyloid positron emission tomography; F-18 sodium fluoride; Cardiac amyloidosis; MOLECULAR-MECHANISMS; TEST ACCURACY; VISUALIZATION; C-11-PIB; DEPOSITS; BINDING; RATIO; BIAS;
D O I
10.1016/j.jjcc.2020.07.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The purpose of the current investigation was to evaluate the diagnostic accuracy of amyloid and F-18 sodium fluoride (NaF) positron emission tomography/computed tomography (PET/CT) for the detection of cardiac amyloidosis (CA) using diagnostic accuracy test. Materials and methods: The PubMed, Cochrane, and EMBASE database, from the earliest available date of indexing through February 29, 2020, were searched for results investigating the diagnostic accuracy of amyloid and F-18 NaF PET for the diagnosis of CA. We calculated the pooled sensitivities and specificities of included studies, calculated positive and negative likelihood ratios (LR+ and LR-), and obtained summary receiver operating characteristic (SROC) curves. Results: Across 13 studies with 14 results (90 patients), the pooled sensitivity of amyloid PET was 0.97 and a pooled specificity was 0.98. The pooled sensitivity of F-18 NaF PET was 0.63 and a pooled specificity was 1.00. The pooled sensitivity of combined amyloid and F-18 NaF PET was 0.88 and a pooled specificity was 0.98. Conclusion: Amyloid PET has a high sensitivity and specificity for the detection of CA. However, F-18 NaF PET showed relatively low sensitivity with high specificity. At present, the literature regarding the use of amyloid and F-18 NaF PET for diagnosis of CA is still limited; thus, further large multicenter studies would be necessary to substantiate the diagnostic accuracy of amyloid and F-18 NaF PET for detection of CA. (C) 2020 Published by Elsevier Ltd on behalf of Japanese College of Cardiology.
引用
收藏
页码:618 / 625
页数:8
相关论文
共 50 条
  • [1] Diagnostic performance of CMR, SPECT, and PET imaging for the detection of cardiac amyloidosis: a meta-analysis
    Wu, Zhaoye
    Yu, Chunjing
    [J]. BMC CARDIOVASCULAR DISORDERS, 2021, 21 (01)
  • [2] Diagnostic performance of CMR, SPECT, and PET imaging for the detection of cardiac amyloidosis: a meta-analysis
    Zhaoye Wu
    Chunjing Yu
    [J]. BMC Cardiovascular Disorders, 21
  • [3] Diagnostic performance of imaging investigations in detecting and differentiating cardiac amyloidosis: a systematic review and meta-analysis
    Brownrigg, Jack
    Lorenzini, Massimiliano
    Lumley, Matthew
    Elliott, Perry
    [J]. ESC HEART FAILURE, 2019, 6 (05): : 1041 - 1051
  • [4] Diagnostic performance of F-18 FDG PET for detection of cardiac sarcoidosis; A systematic review and meta-analysis
    Seong-Jang Kim
    Kyoungjune Pak
    Keunyoung Kim
    [J]. Journal of Nuclear Cardiology, 2020, 27 : 2103 - 2115
  • [5] Diagnostic performance of F-18 FDG PET for detection of cardiac sarcoidosis; A systematic review and meta-analysis
    Kim, Seong-Jang
    Pak, Kyoungjune
    Kim, Keunyoung
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (06) : 2103 - 2115
  • [6] Diagnostic performance of advanced cardiac imaging for detection of cardiac sarcoidosis: a systematic review and meta-analysis
    Ballo, H.
    Saraste, A.
    Doghman, F.
    Knuuti, J.
    [J]. EUROPEAN HEART JOURNAL, 2020, 41 : 325 - 325
  • [7] AI FOR THE DETECTION OF CARDIAC AMYLOIDOSIS: INSIGHTS FROM A SYSTEMATIC REVIEW AND META-ANALYSIS
    Adams, Cobi
    Gorrie, Natasha
    Raftopulos, Nikki
    Olsen, Nick
    Bart, Nicole
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 400 - 400
  • [8] Diagnostic Performance of Echocardiography for the Detection of Acute Cardiac Allograft Rejection: A Systematic Review and Meta-Analysis
    Lu, Wei
    Zheng, Jun
    Pan, Xudong
    Sun, Lizhong
    [J]. PLOS ONE, 2015, 10 (03):
  • [9] Diagnostic performance of choline PET for detection of hyperfunctioning parathyroid glands in hyperparathyroidism: a systematic review and meta-analysis
    Treglia, Giorgio
    Piccardo, Arnoldo
    Imperiale, Alessio
    Strobel, Klaus
    Kaufmann, Philipp A.
    Prior, John O.
    Giovanella, Luca
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (03) : 751 - 765
  • [10] Diagnostic performance of choline PET for detection of hyperfunctioning parathyroid glands in hyperparathyroidism: a systematic review and meta-analysis
    Giorgio Treglia
    Arnoldo Piccardo
    Alessio Imperiale
    Klaus Strobel
    Philipp A. Kaufmann
    John O. Prior
    Luca Giovanella
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2019, 46 : 751 - 765