Detection performance of PCR for Legionella pneumophila in environmental samples: a systematic review and meta-analysis

被引:4
|
作者
Yin, Xin [1 ,2 ]
Chen, Ying-Zhou [1 ,3 ]
Ye, Qi-Qing [1 ,2 ]
Liao, Li-Juan [3 ]
Cai, Zhuo-Rui [4 ]
Lin, Min [5 ]
Li, Jia-Na [6 ]
Zhang, Geng-Biao [6 ]
Peng, Xiao-Li [5 ]
Shi, Wen-Fang [7 ]
Guo, Xu-Guang [1 ,7 ,8 ,9 ]
机构
[1] Guangzhou Med Univ, Affiliated Hosp 3, Dept Clin Lab Med, Guangzhou 510150, Peoples R China
[2] Guangzhou Med Univ, Dept Pediat, Pediat Sch, Guangzhou 510182, Peoples R China
[3] Guangzhou Med Univ, Dept Clin Med, Sch Clin 1, Guangzhou 511436, Peoples R China
[4] Guangzhou Med Univ, Dept Prevent Med, Sch Publ Hlth, Guangzhou 511436, Peoples R China
[5] Guangzhou Med Univ, Clin Sch Tradit Chinese & Western Med, Dept Tradit Chinese & Western Med Clin Med, Guangzhou 511436, Peoples R China
[6] Guangzhou Med Univ, Sch Clin 2, Dept Med Imaging, Guangzhou 511436, Peoples R China
[7] Guangzhou Med Univ, Sch Clin 3, Dept Clin Med, Guangzhou 511436, Peoples R China
[8] Guangzhou Med Univ, Affiliated Hosp 3, Key Lab Major Obstetr Dis Guangdong Prov, Guangzhou 510150, Peoples R China
[9] Guangzhou Med Univ, Affiliated Hosp 3, Guangdong Higher Educ Inst, Key Lab Reprod & Genet, Guangzhou 510150, Peoples R China
关键词
Legionella pneumophila; L; pneumophila; PCR; Diagnosis; REAL-TIME PCR; POLYMERASE-CHAIN-REACTION; WATER SAMPLES; QUANTITATIVE PCR; CULTURE; SPP; QUANTIFICATION; QPCR;
D O I
10.1186/s12941-022-00503-9
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background Legionellosis remains a public health problem. The most common diagnostic method to detect Legionella pneumophila (L. pneumophila) is culture. Polymerase chain reaction (PCR) is a fast and accurate method for this detection in environmental samples. Methods Four databases were searched for studies that evaluated the detection efficiency of PCR in L. pneumophila. The quality evaluation was conducted using Review Manager 5.3. We used Meta-DiSc 1.4 software and the Stata 15.0 software to create forest plots, a meta-regression, a bivariate boxplot and a Deeks' funnel plot. Results A total of 18 four-fold tables from 16 studies were analysed. The overall pooled sensitivity and specificity of PCR was 94% and 72%, respectively. The positive likelihood ratio (RLR) and negative likelihood ratio (NLR) was 2.73 and 0.12, respectively. The result of the diagnostic odds ratio (DOR) was 22.85 and the area under the curve (AUC) was 0.7884. Conclusion Establishing a laboratory diagnostic tool for L. pneumophila detection is important for epidemiological studies. In this work, PCR demonstrated a promising diagnostic accuracy for L. pneumophila.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Detection performance of PCR for Legionella pneumophila in environmental samples: a systematic review and meta-analysis
    Xin Yin
    Ying-Zhou Chen
    Qi-Qing Ye
    Li-Juan Liao
    Zhuo-Rui Cai
    Min Lin
    Jia-Na Li
    Geng-Biao Zhang
    Xiao-Li Peng
    Wen-Fang Shi
    Xu-Guang Guo
    Annals of Clinical Microbiology and Antimicrobials, 21
  • [2] Evaluation of the prevalence of Legionella pneumophila in Iranian clinical samples: A systematic review and meta-analysis
    Khaledi, Azad
    Esmaeili, Seyed-Alireza
    Vazini, Hossein
    Karami, Pezhman
    Bahrami, Afsane
    Sahebkar, Amirhossein
    MICROBIAL PATHOGENESIS, 2019, 129 : 93 - 98
  • [3] Use of a new seminested PCR combined with enzymatic digestion analysis for detection and differentiation of Legionella species and Legionella pneumophila in environmental water and sputum samples
    Zhao, Li-Wei
    Xuan, Rui-Hong
    Zhu, Qing-Yi
    Hu, Chao-Hui
    Liu, Yang-Min
    Chen, Wen-Cong
    AFRICAN JOURNAL OF MICROBIOLOGY RESEARCH, 2012, 6 (10): : 2522 - 2527
  • [4] Occurrence of Legionella pneumophila in environmental samples
    Devos, L
    Boon, N
    Verstraete, W
    EUROPEAN SYMPOSIUM ON ENVIRONMENTAL BIOTECHNOLOGY, ESEB 2004, 2004, : 189 - 189
  • [5] Comparison of PCR and Culture for Detection of Legionella pneumophila in Bronchoalveolar Fluid Samples
    Mirkalantari, Shiva
    JOURNAL OF PURE AND APPLIED MICROBIOLOGY, 2015, 9 : 421 - 424
  • [6] Detection and quantification of Legionella pneumophila in water samples using competitive PCR
    Declerck, Priscilla
    Behets, Jonas
    Lammertyn, Elke
    Lebeau, Ilya
    Anne, Jozef
    Ollevier, Frans
    CANADIAN JOURNAL OF MICROBIOLOGY, 2006, 52 (06) : 584 - 590
  • [7] Accuracy of real-time PCR for the detection of paratuberculosis in actual samples: A systematic review and meta-analysis
    Liu, Tian
    Lin, Hanyu
    Zhu, Lingling
    Yang, Aaron
    Yao, Huochun
    Pan, Zihao
    PREVENTIVE VETERINARY MEDICINE, 2025, 237
  • [8] Prevalence of Legionella pneumophila among patients suffering from pneumonia: a Middle East systematic review and meta-analysis
    Mohseni, Fatemeh
    Khaledi, Azad
    REVIEWS AND RESEARCH IN MEDICAL MICROBIOLOGY, 2022, 33 (01): : E82 - E88
  • [9] Evaluation of nested PCR assays for the detection of Legionella pneumophila in a wide range of aquatic samples
    Devos, L
    Clymans, K
    Boon, N
    Verstraete, W
    JOURNAL OF APPLIED MICROBIOLOGY, 2005, 99 (04) : 916 - 925
  • [10] Evaluation of a real-time PCR hybridization assay for rapid detection of Legionella pneumophila in hospital and environmental water samples
    Levi, K
    Smedley, J
    Towner, KJ
    CLINICAL MICROBIOLOGY AND INFECTION, 2003, 9 (07) : 754 - 758