Use of a new seminested PCR combined with enzymatic digestion analysis for detection and differentiation of Legionella species and Legionella pneumophila in environmental water and sputum samples

被引:0
|
作者
Zhao, Li-Wei [1 ]
Xuan, Rui-Hong [1 ]
Zhu, Qing-Yi [1 ]
Hu, Chao-Hui [1 ]
Liu, Yang-Min [1 ]
Chen, Wen-Cong [1 ]
机构
[1] Guangzhou Kingmed Ctr, Clin Lab, Guangzhou 510330, Guangdong, Peoples R China
来源
关键词
Legionella; seminested PCR; enzymatic digestion analysis; LEGIONNAIRES-DISEASE; IDENTIFICATION; INFECTION; SPECIMENS;
D O I
10.5897/AJMR12.032
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
A new seminested PCR combined with enzymatic digestion analysis method was developed for detection and differentiation of Legionella spp. and Legionella pneumophila in environmental water and sputum samples. The seminested PCR was a novel target for all Legionella testing; it detected 42 Legionella spp. and 12 other bacterial species without the cross-reactivity, and detected 1 fg of Legionella DNA in each PCR. The enzymatic digestion analysis was differentiated L. pneumophila from other Legionella spp.. The aim of this study was to investigate the usefulness of the new scheme for detection of L. pneumophila in environmental and sputum samples. A total of 24 water samples and 215 sputum samples were detected by the new scheme. Of 24 environmental water samples examined by this scheme and culture, 20 were found to be positive for Legionella spp.. Of these 20 samples, 85.0% (17 of 20) were positive by both PCR and culture, 10.0% (2 of 20) were positive by PCR alone, and 5.0% (1 of 20) was positive by culture alone. Among these 20 samples, 14 samples were positive for L. pneumophila by enzymatic digestion analysis, and they were verified by gene sequence analysis. Of the 215 sputum samples examined, PCR was found to be an essential diagnostic tool because only 6.25% (1 of 16) sputum samples were determined to be L. pneumophila by culture. The seminested PCR combined with enzymatic digestion analysis is an appropriate and useful method for Legionella surveillance. The combination of this scheme with culture method may be the best protocol for the detection of Legionella species in environmental water and sputum samples.
引用
收藏
页码:2522 / 2527
页数:6
相关论文
共 33 条
  • [1] Validation of a new seminested PCR-based detection method for Legionella pneumophila
    Yanez, M. A.
    Barbera, V. M.
    Catalan, V.
    JOURNAL OF MICROBIOLOGICAL METHODS, 2007, 70 (01) : 214 - 217
  • [2] New system for the detection of Legionella pneumophila in water samples
    Parraga-Nino, Noemi
    Quero, Sara
    Ventos-Alfonso, Alba
    Uria, Naroa
    Castillo-Fernandez, Oscar
    Ezenarro, Josune J.
    Munoz, Francesc-Xavier
    Garcia-Nunez, Marian
    Sabria, Miguel
    TALANTA, 2018, 189 : 324 - 331
  • [3] Detection and quantification of Legionella pneumophila in water samples using competitive PCR
    Declerck, Priscilla
    Behets, Jonas
    Lammertyn, Elke
    Lebeau, Ilya
    Anne, Jozef
    Ollevier, Frans
    CANADIAN JOURNAL OF MICROBIOLOGY, 2006, 52 (06) : 584 - 590
  • [4] Detection performance of PCR for Legionella pneumophila in environmental samples: a systematic review and meta-analysis
    Xin Yin
    Ying-Zhou Chen
    Qi-Qing Ye
    Li-Juan Liao
    Zhuo-Rui Cai
    Min Lin
    Jia-Na Li
    Geng-Biao Zhang
    Xiao-Li Peng
    Wen-Fang Shi
    Xu-Guang Guo
    Annals of Clinical Microbiology and Antimicrobials, 21
  • [5] Detection performance of PCR for Legionella pneumophila in environmental samples: a systematic review and meta-analysis
    Yin, Xin
    Chen, Ying-Zhou
    Ye, Qi-Qing
    Liao, Li-Juan
    Cai, Zhuo-Rui
    Lin, Min
    Li, Jia-Na
    Zhang, Geng-Biao
    Peng, Xiao-Li
    Shi, Wen-Fang
    Guo, Xu-Guang
    ANNALS OF CLINICAL MICROBIOLOGY AND ANTIMICROBIALS, 2022, 21 (01)
  • [6] Simultaneous detection of Legionella species and Legionella pneumophila by duplex PCR (dPCR) assay in cooling tower water samples from Jakarta, Indonesia
    Yasmon, Andi
    Yusmaniar
    Karuniawati, Anis
    Bela, Budiman
    MEDICAL JOURNAL OF INDONESIA, 2010, 19 (04) : 223 - 227
  • [7] Detection methods for Legionella pneumophila in diverse environmental conditions: A comparative study of FISH, seminested PCR and conventional culture
    Alver, Ipek Ada
    Kimiran, Ayten
    MALAYSIAN JOURNAL OF MICROBIOLOGY, 2024, 20 (03) : 302 - 310
  • [8] Detection of Legionella spp. and Legionella pneumophila in water samples of Spain by specific real-time PCR
    Cristina Grúas
    Silvia Llambi
    M. Victoria Arruga
    Archives of Microbiology, 2014, 196 : 63 - 71
  • [9] Detection of Legionella spp. and Legionella pneumophila in water samples of Spain by specific real-time PCR
    Gruas, Cristina
    Llambi, Silvia
    Victoria Arruga, M.
    ARCHIVES OF MICROBIOLOGY, 2014, 196 (01) : 63 - 71
  • [10] Novel PCR-probe assay for detection of and discrimination between Legionella pneumophila and other Legionella species in clinical samples
    van der Zee, A
    Verbakel, H
    de Jong, C
    Pot, R
    Bergmans, A
    Peeters, M
    Schneeberger, P
    Schellekens, J
    JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (03) : 1124 - 1125