摘要
Purpose: A research prototype for high‐performance dual‐energy (DE) imaging of the chest is under development. This paper discusses the development and characterization of a cardiac gating system designed to precisely trigger the imaging system according to cardiac phase and minimize anatomical misregistration due to heart motion. Method and Materials: A fingertip pulse oximeter was employed to measure the peripheral pulse waveform and trigger x‐ray exposures during the quiescent phase of the heart (diastole). Temporal delays accounted in the timing scheme include physiological pulse propagation, waveform processing, and imaging system delays (filter‐wheel, bucky‐grid, and flat‐panel detector). An empirical model of the diastolic period allows calculation of the implemented delay, timp, required to trigger correctly at any patient heart‐rate. Performance was evaluated in terms of accuracy and precision of diastole‐trigger coincidence and expert assessment of cardiac motion artifact in gated and ungated DE images. Results: The model suggests a triggering scheme characterized by two heart‐rate (HR) regimes: below a HR‐threshold, sufficient time exists to expose on the same heartbeat [formula omitted]; above the HR‐threshold, a characteristic timp(HR) delays exposure to the subsequent heartbeat, accounting for all fixed and variable system delays. Initial implementation indicated 83% accuracy in diastole‐trigger coincidence. By modifying the HR estimation method (reduced temporal smoothing of the pulse waveform), trigger accuracy of 100% was achieved. Cardiac‐gated DE patient images demonstrate significantly reduced cardiac motion as assessed by expert radiologists. Conclusion: A pulse oximeter combined with a cardiac model provides accurate x‐ray triggering and significantly reduces heart motion artifacts. A simple fingertip clip presents logistic, cost, and workflow advantages compared to ECG. The system has been implemented in a clinical research trial, with gated and ungated arms allowing characterization of the impact of cardiac motion artifact on diagnostic performance. Conflict of Interest: Research sponsored in part by Eastman Kodak. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2364 / 2364
页数:1
相关论文
共 50 条
  • [21] Pre-clinical evaluation of a respiratory motion correction technique in dual gated cardiac imaging
    Lamare, Frederic
    Rimoldi, Ornella
    Teras, Mika
    Kokki, Tommi
    Knuuti, Juhani
    Visvikis, Dimitris
    Camici, Paolo
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [22] Optimal kVp selection for dual-energy imaging of the chest: Evaluation by task-specific observer preference tests
    Williams, D. B.
    Siewerdsen, J. H.
    Tward, D. J.
    Paul, N. S.
    Dhanantwari, A. C.
    Shkumat, N. A.
    Richard, S.
    Yorkston, J.
    Van Metter, R.
    MEDICAL PHYSICS, 2007, 34 (10) : 3916 - 3925
  • [23] Image Evaluation of Free-breathing Navigator Echo and Triggered Cardiac-gated Delayed Myocardial Enhancement Magnetic Resonance Imaging in Sedated Infants
    Matsuura, Ryutaro
    Goto, Sachiko
    Sato, Shuhei
    Akagi, Noriaki
    Tahara, Seiji
    ACTA MEDICA OKAYAMA, 2018, 72 (03) : 267 - 273
  • [24] USE OF DUAL-ENERGY CORONARY COMPUTED TOMOGRAPHY FOR EVALUATION OF NECROTIC CORE IN PATIENTS WITH SUDDEN CARDIAC DEATH
    Dwivedi, Aeshita
    Lin, Fay
    Narula, Navneet
    Rizvi, Asim
    Stuijfzand, Wijnand
    Lee, Ji Hyun
    Han, Donghee
    Lu, Yao
    Park, Mahn Won
    Roudsari, Hadi Mirhedayati
    DiFranco, Alessandra
    Yahagi, Kazuyuki
    Torii, Sho
    Kutys, Robert
    Jones, Erica
    Pena, Jessica
    Al'Aref, Subhi
    Eagle, Michael
    Jackson, Dana
    Fowler, David
    Earls, James
    Min, James K.
    Virmani, Renu
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1485 - 1485
  • [25] Original report. Digital radiography with dual-energy subtraction: Improved evaluation of cardiac calcification.
    Gilkeson, RC
    Novak, RD
    Sachs, P
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (05) : 1233 - 1238
  • [26] Evaluation of two free form deformation based motion estimators in cardiac and chest imaging
    Delhay, B
    Clarysse, P
    Lötjönen, J
    Katila, T
    Magnin, IE
    FUNCTIONAL IMAGING AND MODELING OF HEART, PROCEEDINGS, 2005, 3504 : 467 - 476
  • [27] Performance evaluation of dual-energy CT and differential phase contrast CT in quantitative imaging applications
    Zhang, Xin
    Su, Ting
    Yang, Jiecheng
    Zhu, Jiongtao
    Xia, Dongmei
    Zheng, Hairong
    Liang, Dong
    Ge, Yongshuai
    MEDICAL PHYSICS, 2022, 49 (02) : 1123 - 1138
  • [28] Delayed Enhancement Dual-Energy CT versus Cardiac MRI Viability Imaging for Quantifying Myocardial Infarct Size
    Rosenblum, Michael A.
    Ruzsics, Balazs
    Arnoldi, Elisabeth M.
    Bonnema, David D.
    Abro, Joseph
    Gebregziabher, Mulugeta
    Zwerner, Peter L.
    Costello, Philip
    Schoepf, U. J.
    CIRCULATION, 2009, 120 (18) : S375 - S375
  • [29] Dual-Energy Computed Tomography Gemstone Spectral Imaging: A Novel Technique to Determine Human Cardiac Calculus Composition
    Cheng, Ching-Li
    Chang, Hsiao-Huang
    Ko, Shih-Chi
    Huang, Pei-Jung
    Lin, Shan-Yang
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (02) : 283 - 289
  • [30] Dual respiratory and cardiac motion estimation in PET imaging: Methods design and quantitative evaluation
    Feng, Tao
    Wang, Jizhe
    Tsui, Benjamin M. W.
    MEDICAL PHYSICS, 2018, 45 (04) : 1481 - 1490