Nutrition delivery, workload and performance in a model-based ICU glycaemic control system

被引:8
|
作者
Stewart, Kent W. [1 ]
Chase, J. Geoffrey [1 ]
Pretty, Christopher G. [1 ]
Shaw, Geoffrey M. [2 ]
机构
[1] Univ Canterbury, Ctr Bioengn, Dept Mech Engn, Christchurch, New Zealand
[2] Christchurch Hosp, Dept Intens Care, Christchurch, New Zealand
关键词
Glycaemic control; Nutrition delivery; Clinical workload; Intensive care unit; Critical care; Hyperglycaemia; Hypoglycaemia; Model-based; Targeted; Stochastic; CRITICALLY-ILL PATIENTS; INTENSIVE INSULIN THERAPY; RANDOMIZED CONTROLLED-TRIAL; CRITICAL-CARE; GLUCOSE CONTROL; CRITICAL ILLNESS; STRESS HYPERGLYCEMIA; ADULT PATIENTS; MEDICAL ICU; MORTALITY;
D O I
10.1016/j.cmpb.2018.09.005
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and Objective: Hyperglycaemia is commonplace in the adult intensive care unit (ICU), and has been associated with increased morbidity and mortality. Effective glycaemic control (GC) can reduce morbidity and mortality, but has proven difficult. STAR is a model-based GC protocol that uniquely maintains normoglycaemia by changing both insulin and nutrition interventions, and has been proven effective in controlling blood glucose (BG) in the ICU. However, most ICU GC protocols only change insulin interventions, making the variable nutrition aspect of STAR less clinically desirable. This paper compares the performance of STAR modulating only insulin, with three simpler alternative nutrition protocols in clinically evaluated virtual trials. Methods: Alternative nutrition protocols are fixed nutrition rate (100% caloric goal), CB (Cahill et al. best) stepped nutrition rate (60%, 80% and 100% caloric goal for the first 3 days of GC, and 100% thereafter) and SLQ (STAR lower quartile) stepped nutrition rate (65%, 75% and 85% caloric goal for the first 3 days of GC, and 85% thereafter). Each nutrition protocol is simulated with the STAR insulin protocol on a 221 patient virtual cohort, and GC performance, safety and total intervention workload are assessed. Results: All alternative nutrition protocols considerably reduced total intervention workload (14.6-19.8%) due to reduced numbers of nutrition changes. However, only the stepped nutrition protocols achieved similar GC performance to the current variable nutrition protocol. Of the two stepped nutrition protocols, the SLQ nutrition protocol also improved GC safety, almost halving the number of severe hypoglycaemic cases (5 vs. 9, P = 0.42). Conclusions: Overall, the SLQ nutrition protocol was the best alternative to the current variable nutrition protocol, but either stepped nutrition protocol could be adapted by STAR to reduce workload and make it more clinically acceptable, while maintaining its proven performance and safety. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:9 / 18
页数:10
相关论文
共 50 条
  • [21] Clinical validation of a model-based glycaemic control design approach and comparison to other clinical protocols
    Chase, J. Geoffrey
    Shaw, Geoffrey M.
    Hann, Christopher E.
    LeCompte, Aaron
    Lonergan, Timothy
    Willacy, Michael
    Wong, Xing-Wei
    Lin, Jessica
    Lotz, Thomas
    [J]. 2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 3612 - +
  • [22] Assessing health system performance: A model-based approach
    Gerring, John
    Thacker, Strom C.
    Enikolopov, Ruben
    Arevalo, Julian
    Maguire, Matthew
    [J]. SOCIAL SCIENCE & MEDICINE, 2013, 93 : 21 - 28
  • [23] Model-Based Glycaemic Control in Multicentre ICUs within Diabetic Patients: In-silico Analysis
    Razak, Athirah Abdul
    Razak, Normy
    Shah, Norliyana Nor Hisham
    Abu-Samah, Asma
    Jamaludin, Ummu
    Suhaimi, Fatanah
    [J]. INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2020, 16 (03): : 67 - 77
  • [24] Model-Based Automation System to Optimize Drilling Performance
    Koeneke, J.
    Hoehn, O.
    Schuberth, F.
    [J]. OIL GAS-EUROPEAN MAGAZINE, 2016, 42 (01): : 33 - 34
  • [25] Model-based system reconfiguration for dynamic performance management
    Caporuscio, Mauro
    Di Marco, Antinisca
    Inverardi, Paola
    [J]. JOURNAL OF SYSTEMS AND SOFTWARE, 2007, 80 (04) : 455 - 473
  • [26] Model-based control system for advanced diesel combustion
    Takahashi, Motoki
    Yamasaki, Yudai
    Kaneko, Shigehiko
    Fujii, Seiya
    Mizumoto, Ikuro
    Hayashi, Tomofumi
    Asahi, Teruhiko
    Hirata, Mitsuo
    [J]. IFAC PAPERSONLINE, 2019, 52 (05): : 171 - 177
  • [27] An Improved Model-based Control Scheme for Networked System
    Wang, Zhiwen
    Guo, Ge
    Luo, Dongsong
    [J]. 2010 CHINESE CONTROL AND DECISION CONFERENCE, VOLS 1-5, 2010, : 1509 - 1512
  • [28] Model-based feedback control of a microfluidic electroporation system
    Ghadami, M.
    Mahjoob, M. J.
    Shagoshtasbi, H.
    Lee, Y-K
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2013, 23 (12)
  • [29] Hybrid model-based adaptive fuzzy control system
    Chen, JY
    [J]. PROCEEDINGS OF THE 2002 IEEE INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS, VOL 1 & 2, 2002, : 1126 - 1131
  • [30] MODEL-BASED CONTROL SYSTEM FOR A DISTILLATION COLUMN.
    Rhiel, Franz Ferdinand
    Krahl, Franz
    [J]. Chemical Engineering and Technology, 1988, 11 (03): : 188 - 194