Monte Carlo calculations for assessment of radiation dose to patients with congenital heart defects and to staff during cardiac catheterizations

被引:60
|
作者
Schultz, FW
Geleijns, J
Spoelstra, FM
Zoetelief, J
机构
[1] Delft Univ Technol, Interfac Reactor Inst, NL-2629 JB Delft, Netherlands
[2] Leiden Univ, Med Ctr, Dept Radiol, NL-2300 RC Leiden, Netherlands
来源
BRITISH JOURNAL OF RADIOLOGY | 2003年 / 76卷 / 909期
关键词
D O I
10.1259/bjr/21647806
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Effective dose is an important quantity in relation to assessment of radiation risk. Organ and effective doses to paediatric patients undergoing diagnostic and therapeutic heart catheterization procedures can be assessed by combining relatively simple measurements, e.g. of dose-area product (DAP), and calculated dose conversion factors (DCF). This also holds for the radiation dose to the hospital staff, e.g. the cardiologist. Monte Carlo (MC) simulation of radiation transport in mathematical anthropomorphic phantoms is used to obtain the DCFs, which strongly depend on beam quality and geometrical parameters. The performance of a dedicated fast MC code (PCXMC) for patient dosimetry is compared with that of a more elaborate general purpose MC code (MCNP). Resulting organ doses sometimes may differ considerably, partly due to phantom differences. While MCNP uses separate male and female mathematical phantoms, PCXMC uses a hermaphrodite. However, both codes yield effective doses that agree rather well, so PCXMC can be used for convenience. The MCNP code is used to calculate the effective dose to the cardiologist exposed to radiation scattered from the patient. Without protective clothing, effective dose per procedure to the cardiologist is at least two orders of magnitude lower than that to the patient. The effectiveness of various types and thickness of protective clothing has been evaluated for one view of one cardiac catheterization. The results of the calculations do not contradict experimental studies from the literature. MC simulation may serve as a useful tool to improve the accuracy of estimating occupational effective dose from personal dose monitors.
引用
收藏
页码:638 / 647
页数:10
相关论文
共 50 条
  • [41] Development and commissioning of a multileaf collimator model in Monte Carlo dose calculations for intensity-modulated radiation therapy
    Jang, SY
    Vassiliev, ON
    Liu, HH
    Mohan, R
    Siebers, JV
    MEDICAL PHYSICS, 2006, 33 (03) : 770 - 781
  • [42] Radiation dose around a PET scanner installation: Comparison of Monte Carlo simulations, analytical calculations and experimental results
    Lo Meo, S.
    Cicoria, G.
    Campanella, F.
    Mattozzi, M.
    Panebianco, A. S.
    Marengo, M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (04): : 448 - 453
  • [43] Benchmarking and validation of a Geant4-SHADOW Monte Carlo simulation for dose calculations in microbeam radiation therapy
    Cornelius, Iwan
    Guatelli, Susanna
    Fournier, Pauline
    Crosbie, Jeffrey C.
    del Rio, Manuel Sanchez
    Braeuer-Krisch, Elke
    Rosenfeld, Anatoly
    Lerch, Michael
    JOURNAL OF SYNCHROTRON RADIATION, 2014, 21 : 518 - 528
  • [44] Monte Carlo dose calculations of shielding disks with different material combinations in intraoperative electron radiation therapy (IOERT)
    Alhamada, H.
    Simon, S.
    Philippson, C.
    Vandekerkhove, C.
    Jourani, Y.
    Pauly, N.
    Van Gestel, D.
    Reynaert, N.
    CANCER RADIOTHERAPIE, 2020, 24 (02): : 128 - 134
  • [45] CONGENITAL COMPLETE HEART-BLOCK IN PATIENTS WITHOUT ANATOMIC CARDIAC DEFECTS
    SHOLLER, GF
    WALSH, EP
    AMERICAN HEART JOURNAL, 1989, 118 (06) : 1193 - 1198
  • [46] Patients with PHT (sudden cardiac death) in the national Register for congenital Heart Defects
    Abdul-Khaliq, H.
    Pickardt, Th.
    Bauer, U.
    CLINICAL RESEARCH IN CARDIOLOGY, 2011, 100 (09) : 825 - 825
  • [47] RADIATION-DOSE TO THE BREAST DURING MAMMOGRAPHY - A COMPREHENSIVE, REALISTIC MONTE-CARLO CALCULATION
    KULKARNI, RN
    SUPE, SJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (10): : 1257 - 1264
  • [48] Fetal radiation dose in three common CT examinations during pregnancy Monte Carlo study
    Kelaranta, A.
    Makela, T.
    Kaasalainen, T.
    Kortesniemi, M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 43 : 199 - 206
  • [49] Multimodality 3D image fusion with live fluoroscopy reduces radiation dose during catheterization of congenital heart defects
    Buytaert, Dimitri
    Vandekerckhove, Kristof
    Panzer, Joseph
    Campens, Laurence
    Bacher, Klaus
    De Wolf, Daniel
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 10
  • [50] Development of computational pregnant female and fetal models and Monte Carlo dose calculations of radiation dose from positron-emitting tracers
    Xie, Tianwu
    Zaidi, Habib
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57