Monte Carlo calculations for assessment of radiation dose to patients with congenital heart defects and to staff during cardiac catheterizations

被引:60
|
作者
Schultz, FW
Geleijns, J
Spoelstra, FM
Zoetelief, J
机构
[1] Delft Univ Technol, Interfac Reactor Inst, NL-2629 JB Delft, Netherlands
[2] Leiden Univ, Med Ctr, Dept Radiol, NL-2300 RC Leiden, Netherlands
来源
BRITISH JOURNAL OF RADIOLOGY | 2003年 / 76卷 / 909期
关键词
D O I
10.1259/bjr/21647806
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Effective dose is an important quantity in relation to assessment of radiation risk. Organ and effective doses to paediatric patients undergoing diagnostic and therapeutic heart catheterization procedures can be assessed by combining relatively simple measurements, e.g. of dose-area product (DAP), and calculated dose conversion factors (DCF). This also holds for the radiation dose to the hospital staff, e.g. the cardiologist. Monte Carlo (MC) simulation of radiation transport in mathematical anthropomorphic phantoms is used to obtain the DCFs, which strongly depend on beam quality and geometrical parameters. The performance of a dedicated fast MC code (PCXMC) for patient dosimetry is compared with that of a more elaborate general purpose MC code (MCNP). Resulting organ doses sometimes may differ considerably, partly due to phantom differences. While MCNP uses separate male and female mathematical phantoms, PCXMC uses a hermaphrodite. However, both codes yield effective doses that agree rather well, so PCXMC can be used for convenience. The MCNP code is used to calculate the effective dose to the cardiologist exposed to radiation scattered from the patient. Without protective clothing, effective dose per procedure to the cardiologist is at least two orders of magnitude lower than that to the patient. The effectiveness of various types and thickness of protective clothing has been evaluated for one view of one cardiac catheterization. The results of the calculations do not contradict experimental studies from the literature. MC simulation may serve as a useful tool to improve the accuracy of estimating occupational effective dose from personal dose monitors.
引用
收藏
页码:638 / 647
页数:10
相关论文
共 50 条
  • [21] OPTIMISATION OF SCATTER RADIATION TO STAFF DURING CT-FLUOROSCOPY: MONTE CARLO STUDIES
    Gyekye, P. K.
    Becker, F.
    Mensah, S. Y.
    Emi-Reynolds, G.
    RADIATION PROTECTION DOSIMETRY, 2016, 170 (1-4) : 393 - 397
  • [22] Monte Carlo study of patient and medical staff radiation exposures during interventional cardiology
    Bhar, M.
    Mora, S.
    Kadri, O.
    Zein, S.
    Manai, K.
    Incerti, S.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 82 : 200 - 210
  • [23] AN ASSESSMENT OF MONTE CARLO CALCULATIONS TO DETERMINE GAMMA RAY DOSE FROM INTERNAL EMITTERS
    ELLETT, WH
    BROWNELL, GL
    REDDY, AR
    PHYSICS IN MEDICINE AND BIOLOGY, 1968, 13 (02): : 219 - +
  • [24] Patient-specific dose assessment using CBCT images and Monte Carlo calculations
    Aghaz, A.
    Kardan, M. R.
    Deevband, M. R.
    Bahadorzadeh, B.
    Kasesaz, Y.
    Ghadiri, H.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (10)
  • [25] The Monte Carlo Method of Mixed Radiation Field Dose Assessment in the Cytogenetic Biodosimetry
    Powojska, A.
    Slonecka, I.
    Fornalski, K. W.
    ACTA PHYSICA POLONICA A, 2018, 134 (02) : 583 - 589
  • [26] Monte Carlo benchmark for radiation dose assessment in varian on-board imager
    Kim, S.
    Yoo, S.
    Yoshizumi, T.
    Yin, F.
    MEDICAL PHYSICS, 2007, 34 (06) : 2470 - 2470
  • [27] Multicenter Assessment of Radiation Exposure during Pediatric Cardiac Catheterizations Using a Novel Imaging System
    Lamers, Luke J.
    Morray, Brian H.
    Nugent, Alan
    Speidel, Michael
    Suntharos, Petch
    Prieto, Lourdes
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2019, 2019
  • [28] AN INVESTIGATION OF THE RADIATION-DOSE TO STAFF DURING CARDIAC RADIOLOGICAL STUDIES
    JEANS, SP
    FAULKNER, K
    LOVE, HG
    BARDSLEY, RA
    BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (689): : 419 - 428
  • [29] Staff radiation dose during cardiac PET examinations with Rubidium 82
    Bugeiro, M.
    Greppin, I.
    Recordon, M.
    Prior, J.
    Kosinski, M.
    Delaloye, A. Bischof
    Allenbach, G.
    Ding, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S237 - S237
  • [30] Staff radiation dose during cardiac PET examinations with Rubidium 82
    Bugeiro, M.
    Greppin, I.
    Recordon, M.
    Prior, J.
    Kosinski, M.
    Delaloye, A. Bischof
    Allenbach, G.
    Ding, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 (SUPPL 2) : 237 - 237